---
title: "Thermal-Gard Building Products 501/551/601/651 Single Hung"
url: https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-501-551-601-651-single-hung-pictu/
description: "Thermal-Gard Building Products 501/551/601/651 Single Hung Picture Window (THG-K-22, Picture Window, Vinyl): U-Factor 0.21-0.24, SHGC 0.24-0.27, 4 options."
---

Window · Vinyl Frame NFRC THG · Product Line THG-K-22

# Thermal-Gard Building Products, Inc. — 501/551/601/651 Single Hung Picture Window · Picture Window

Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.21 across 4 certified glazing configurations covering Northern, North-Central. Ranked #742 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.24 to 0.27.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.24-0.27

- **Certified Options** : 4

- **Category Standing** : #742 of 1,352

## How does Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window compare thermally against Window peers?

Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window at rank #742 of 1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.24-0.27 band.

Zone eligibility across EPA boundaries reaches 2 markets (Northern, North-Central). 2 combinations qualify in the Northern Zone alongside 0 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2024-08-12 and v7.0 data certification on 2025-08-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4 certified glazing combinations for 501/551/601/651 Single Hung Picture Window (NFRC THG) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 2 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 4 packages (0 Most Eff.) |
| **South-Central** | Not Listed | <= 0.28 | <= 0.23 | 0 packages (0 Most Eff.) |
| **Southern** | Not Listed | <= 0.32 | <= 0.23 | 0 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**DRUTEX S.A.** — IGLO LIGHT Casement](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-light-casement-413182/) | Vinyl | 0.21 | 0.17 | 5 |
| [**DRUTEX S.A.** — IGLO LIGHT Transom (Awning)](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-light-transom-awning-413183/) | Vinyl | 0.21 | 0.17 | 5 |
| [**Kohltech International, Ltd.** — Supreme Single Glider](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-supreme-single-glider-413493/) | Vinyl | 0.21 | 0.21 | 11 |
| [**Energy King Windows & Doors Inc.** — Pro Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/energy-king-windows-doors-inc-pro-series-horizontal-slider-414084/) | Vinyl | 0.21 | 0.22 | 12 |
| [**Kohltech International, Ltd.** — Supreme Single Hung](https://ela-ecolandscapingassn.org/windows/models/kohltech-international-ltd-supreme-single-hung-413494/) | Vinyl | 0.21 | 0.21 | 15 |

## What other certified series does Thermal-Gard Building Products, Inc. produce?

Compare other active Thermal-Gard Building Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [851/951 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-851-951-casement-picture-window-4/)

U-Factor 0.21–0.25 · 8 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-851-951-casement-picture-window-4/)

Double HungMin U 0.22

### [505/555/605/655 Double Hung](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-505-555-605-655-double-hung-41416/)

U-Factor 0.22–0.26 · 16 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-505-555-605-655-double-hung-41416/)

Double SliderMin U 0.22

### [507/557/607/657 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-507-557-607-657-horizontal-slider/)

U-Factor 0.22–0.25 · 4 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-507-557-607-657-horizontal-slider/)

Sliding Patio DoorMin U 0.24

### [592/692 Patio Door](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-592-692-patio-door-414161/)

U-Factor 0.24–0.25 · 2 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-592-692-patio-door-414161/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window appear below.

### How well does 501/551/601/651 Single Hung Picture Window by Thermal-Gard Building Products, Inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 4 configurations for Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window covering Northern, North-Central, dropping down to U 0.21 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Does Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window qualify for the ENERGY STAR Northern Zone?

Yes, 2 packages satisfy Northern ENERGY STAR Version 7.0 rules in 501/551/601/651 Single Hung Picture Window. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### What conductive BTU/hr difference separates 501/551/601/651 Single Hung Picture Window from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### When should a buyer skip Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 501/551/601/651 Single Hung Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Is 501/551/601/651 Single Hung Picture Window suitable for sunbelt cooling-dominated homes?

Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window carries zero Southern Zone approvals (0 options; SHGC 0.24-0.27). Cooling-dominated sunbelt homes should look at peer lines certified to SHGC <= 0.23.

### Are all 4 501/551/601/651 Single Hung Picture Window configurations ENERGY STAR Most Efficient?

501/551/601/651 Single Hung Picture Window holds zero Most Efficient entries across its 4 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### Do 2026 501/551/601/651 Single Hung Picture Window installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 501/551/601/651 Single Hung Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### What permanent glass etch marks verify 501/551/601/651 Single Hung Picture Window after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line THG-K-22 and NFRC ID THG before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermal-Gard Building Products, Inc. 501/551/601/651 Single Hung Picture Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
