title: "Thermal-Gard Building Products 505/555/605/655 Double Hung"
url: https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-505-555-605-655-double-hung-41416/
description: "Thermal-Gard Building Products 505/555/605/655 Double Hung (THG-K-20, Double Hung, Vinyl): U-Factor 0.22-0.26, SHGC 0.22-0.24, 16 options across 4 ENERGY."
---

Window · Vinyl Frame NFRC THG · Product Line THG-K-20

# Thermal-Gard Building Products, Inc. — 505/555/605/655 Double Hung · Double Hung

Thermal-Gard Building Products, Inc. engineered the 505/555/605/655 Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 16 glass-spacer combinations from 0.22 to 0.26 U-Factor and 0.22 to 0.24 SHGC. Relative to other Vinyl models tracked under NFRC THG, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.22-0.24

- **Certified Options** : 16

- **Category Standing** : #831 of 1,352

## How does Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung compare thermally against Window peers?

Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung at rank #831 of 1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.22-0.24 band.

Regional qualification covers Northern, North-Central, South-Central, Southern. 6 combinations qualify in the Northern Zone alongside 9 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2024-08-12 and v7.0 data certification on 2024-09-18. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 16 certified glazing combinations for 505/555/605/655 Double Hung (NFRC THG) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 6 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 13 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 9 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 9 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Advent Windows and Doors** — Ascend Series PW](https://ela-ecolandscapingassn.org/windows/models/advent-windows-and-doors-ascend-series-pw-413077/) | Vinyl | 0.22 | 0.14 | 16 |
| [**Taylors Window and Screen, Inc.** — 7000/8000 Series Picture Window](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-7000-8000-series-picture-window-414198/) | Vinyl | 0.22 | 0.19 | 14 |
| [**Energy King Windows & Doors Inc.** — Pro Series Double Hung](https://ela-ecolandscapingassn.org/windows/models/energy-king-windows-doors-inc-pro-series-double-hung-414083/) | Vinyl | 0.22 | 0.22 | 12 |
| [**Taylors Window and Screen, Inc.** — 1800/1830 RR/NC Picture Window](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-1800-1830-rr-nc-picture-window-414200/) | Vinyl | 0.22 | 0.19 | 12 |
| [**California Deluxe Windows Industries, Inc.** — S-6300 Tilt & Turn Window](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-window-413/) | Vinyl | 0.22 | 0.13 | 22 |

## What other certified series does Thermal-Gard Building Products, Inc. produce?

Compare other active Thermal-Gard Building Products, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [501/551/601/651 Single Hung Picture Window](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-501-551-601-651-single-hung-pictu/)

U-Factor 0.21–0.24 · 4 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-501-551-601-651-single-hung-pictu/)

Picture WindowMin U 0.21

### [851/951 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-851-951-casement-picture-window-4/)

U-Factor 0.21–0.25 · 8 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-851-951-casement-picture-window-4/)

Double SliderMin U 0.22

### [507/557/607/657 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-507-557-607-657-horizontal-slider/)

U-Factor 0.22–0.25 · 4 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-507-557-607-657-horizontal-slider/)

Sliding Patio DoorMin U 0.24

### [592/692 Patio Door](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-592-692-patio-door-414161/)

U-Factor 0.24–0.25 · 2 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermal-gard-building-products-inc-592-692-patio-door-414161/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung appear below.

### Where does Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung stand thermally among ENERGY STAR Window lines?

Across 16 tested NFRC glazing configurations, Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.22 minimum U-Factor and 0.22-0.24 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

### Which glazing options in Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung meet Northern climate limits?

Cold-climate buyers get 6 compliant Northern packages inside 505/555/605/655 Double Hung, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.26 options.

### What conductive BTU/hr difference separates 505/555/605/655 Double Hung from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 505/555/605/655 Double Hung at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying 505/555/605/655 Double Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 505/555/605/655 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### Is 505/555/605/655 Double Hung suitable for sunbelt cooling-dominated homes?

Yes, 505/555/605/655 Double Hung holds 9 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.22 SHGC in cooling climates.

### How many Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung variants earn ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 16 505/555/605/655 Double Hung options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What federal compliance checks govern 2026 505/555/605/655 Double Hung window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How can homeowners confirm delivered Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line THG-K-20 and NFRC ID THG before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermal-Gard Building Products, Inc. 505/555/605/655 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)