---
title: "Thermo-Tech Windows 2630 Fixed Casement Specs (U 0.15)"
url: https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2630-fixed-casement-414173/
description: "Thermo-Tech Windows 2630 Fixed Casement (TTW-A-11, Picture Window, Vinyl): U-Factor 0.15-0.28, SHGC 0.13-0.49, 630 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC TTW · Product Line TTW-A-11 ENERGY STAR Most Efficient Eligible

# Thermo-Tech Windows — 2630 Fixed Casement · Picture Window

Across 8 Thermo-Tech Windows certified families, 2630 Fixed Casement supplies 630 Picture Window configurations starting at 0.15 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.49 SHGC. Its thermal floor ranks #136 of 1,352 category entries—0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.13-0.49

- **Certified Options** : 630

- **Category Standing** : #136 of 1,352

## How does Thermo-Tech Windows 2630 Fixed Casement compare thermally against Window peers?

Thermo-Tech Windows 2630 Fixed Casement achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 2630 Fixed Casement spans 630 NFRC test records (TTW), ranking #136 of 1,352 Window families (tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%). Its 0.15 thermal floor compares at -0.04 against the Vinyl median (0.19).

Climate coverage for Thermo-Tech Windows 2630 Fixed Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 359 configurations meet ENERGY STAR Most Efficient criteria while 337 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2024-02-10 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 630 certified glazing combinations for 2630 Fixed Casement (NFRC TTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 337 packages (188 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 419 packages (304 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 439 packages (178 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 439 packages (223 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**ProVia LLC** — Vinyl Casement Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-casement-window-413951/) | Vinyl | 0.15 | 0.06 | 411 |
| [**ProVia LLC** — Vinyl Awning Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-awning-window-413952/) | Vinyl | 0.15 | 0.06 | 397 |
| [**Interstate Building Materials, Inc.** — 440/6800 Single Hung](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-440-6800-single-hung-413330/) | Vinyl | 0.15 | 0.18 | 380 |
| [**Interstate Building Materials, Inc.** — 440/6800 Single Slider](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-440-6800-single-slider-413329/) | Vinyl | 0.15 | 0.18 | 380 |
| [**Slocomb Windows and Doors, Inc** — 400/500 Series Double Hung](https://ela-ecolandscapingassn.org/windows/models/slocomb-windows-and-doors-inc-400-500-series-double-hung-414096/) | Vinyl | 0.15 | 0.14 | 322 |

## What other certified series does Thermo-Tech Windows produce?

Compare other active Thermo-Tech Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [2555 Picture Window](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2555-picture-window-414175/)

U-Factor 0.14–0.32 · 930 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2555-picture-window-414175/)

Awning (Projected)Min U 0.15

### [2600 Awning w/ 2601 Sash](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-awning-w-2601-sash-414177/)

U-Factor 0.15–0.30 · 599 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-awning-w-2601-sash-414177/)

Casement WindowsMin U 0.16

### [2600 Casement w/ 2601 Sash](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-casement-w-2601-sash-414176/)

U-Factor 0.16–0.29 · 607 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-casement-w-2601-sash-414176/)

Single SliderMin U 0.22

### [7400 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-7400-horizontal-slider-414170/)

U-Factor 0.22–0.29 · 263 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-7400-horizontal-slider-414170/)

Sliding Patio DoorMin U 0.23

### [5500 SLPD](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-5500-slpd-414174/)

U-Factor 0.23–0.28 · 246 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-5500-slpd-414174/)

Single HungMin U 0.23

### [7100 Single Hung](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-7100-single-hung-414171/)

U-Factor 0.23–0.30 · 257 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-7100-single-hung-414171/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermo-Tech Windows 2630 Fixed Casement appear below.

### What thermal performance numbers separate Thermo-Tech Windows 2630 Fixed Casement from peers?

Testing puts Thermo-Tech Windows 2630 Fixed Casement at rank #136 of 1,352 Window entries with U 0.15 to 0.28 across 630 configurations. Solar heat gain ranges between 0.13 and 0.49 across Northern, North-Central, South-Central, Southern.

### Does Thermo-Tech Windows 2630 Fixed Casement qualify for the ENERGY STAR Northern Zone?

Prescriptive Northern compliance covers 337 2630 Fixed Casement packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from 2630 Fixed Casement's 0.15 minimum U-Factor?

Using NFRC TTW U-Factor 0.15, a 15 sq ft Fixed Window (FIXD) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

### What homeowner profiles are a poor match for Thermo-Tech Windows 2630 Fixed Casement?

Skip 2630 Fixed Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 2630 Fixed Casement options exceeding U 0.22.

### What Southern ENERGY STAR v7.0 options exist in 2630 Fixed Casement?

Warm-climate homeowners have 439 Southern-approved options within 2630 Fixed Casement spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### How many Thermo-Tech Windows 2630 Fixed Casement variants earn ENERGY STAR Most Efficient?

Only 359 options out of 630 (57.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Thermo-Tech Windows 2630 Fixed Casement, usually requiring triple-pane or upgraded Low-E coatings.

### What federal compliance checks govern 2026 2630 Fixed Casement window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 2630 Fixed Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do you cross-check NFRC TTW and product line TTW-A-11 on delivery?

Match the NFRC thermal sticker for code TTW and line TTW-A-11 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermo-Tech Windows 2630 Fixed Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
