title: "Thermo-Tech Windows 7100 Single Hung Specs (U 0.23)"
url: https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-7100-single-hung-414171/
description: "Thermo-Tech Windows 7100 Single Hung (TTW-A-9, Single Hung, Vinyl): U-Factor 0.23-0.30, SHGC 0.17-0.49, 257 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC TTW · Product Line TTW-A-9

# Thermo-Tech Windows — 7100 Single Hung · Single Hung

Positioning #936/1,352 in certified Window, Thermo-Tech Windows 7100 Single Hung pairs Vinyl frame construction with 257 glazing options rated between 0.17 and 0.49 SHGC across Northern, North-Central, South-Central, Southern. Across 8 certified Thermo-Tech Windows product families, its thermal resistance spans 0.23 to 0.30 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.17-0.49

- **Certified Options** : 257

- **Category Standing** : #936 of 1,352

## How does Thermo-Tech Windows 7100 Single Hung compare thermally against Window peers?

Thermo-Tech Windows 7100 Single Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 7100 Single Hung reaches 0.23 on its lowest-conductivity package — #716 of 1,009 in Vinyl, tied with 81 others at 0.23, more insulating than 21.0% of Vinyl lines (+0.04 vs Vinyl peers). Pairing NFRC ID TTW across multi-pane fills shifts U-Factor from 0.30 down toward 0.23.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 33 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors TTW to 2024-02-10 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 257 certified glazing combinations for 7100 Single Hung (NFRC TTW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 33 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 61 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 90 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 220 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Anlin Industries** — Catalina/Del Mar/Extreme Horizontal Sliding Window](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-horizontal-sliding-window/) | Vinyl | 0.23 | 0.13 | 259 |
| [**Anlin Industries** — Catalina/Del Mar/Extreme Single Hung Window](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-del-mar-extreme-single-hung-window-413028/) | Vinyl | 0.23 | 0.13 | 259 |
| [**Silver Line Building Products** — 2050/2130/2250/2350 Picture Window](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-2050-2130-2250-2350-picture-window-414/) | Vinyl | 0.23 | 0.20 | 242 |
| [**Thompson Creek Window Company** — 7800 Single Hung](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-single-hung-414145/) | Vinyl | 0.23 | 0.18 | 242 |
| [**Anlin Industries** — Catalina-E/Del Mar-E/Bayview/Panoramic/Extreme-E Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/anlin-industries-catalina-e-del-mar-e-bayview-panoramic-extreme-e-ho/) | Vinyl | 0.23 | 0.13 | 230 |

## What other certified series does Thermo-Tech Windows produce?

Compare other active Thermo-Tech Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [2555 Picture Window](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2555-picture-window-414175/)

U-Factor 0.14–0.32 · 930 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2555-picture-window-414175/)

Awning (Projected)Min U 0.15

### [2600 Awning w/ 2601 Sash](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-awning-w-2601-sash-414177/)

U-Factor 0.15–0.30 · 599 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-awning-w-2601-sash-414177/)

Picture WindowMin U 0.15

### [2630 Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2630-fixed-casement-414173/)

U-Factor 0.15–0.28 · 630 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2630-fixed-casement-414173/)

Casement WindowsMin U 0.16

### [2600 Casement w/ 2601 Sash](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-casement-w-2601-sash-414176/)

U-Factor 0.16–0.29 · 607 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-2600-casement-w-2601-sash-414176/)

Single SliderMin U 0.22

### [7400 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-7400-horizontal-slider-414170/)

U-Factor 0.22–0.29 · 263 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-7400-horizontal-slider-414170/)

Sliding Patio DoorMin U 0.23

### [5500 SLPD](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-5500-slpd-414174/)

U-Factor 0.23–0.28 · 246 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thermo-tech-windows-5500-slpd-414174/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thermo-Tech Windows 7100 Single Hung appear below.

### What thermal performance numbers separate Thermo-Tech Windows 7100 Single Hung from peers?

Testing puts Thermo-Tech Windows 7100 Single Hung at rank #936 of 1,352 Window entries with U 0.23 to 0.30 across 257 configurations. Solar heat gain ranges between 0.17 and 0.49 across Northern, North-Central, South-Central, Southern.

### Can homeowners install 7100 Single Hung in cold Northern ENERGY STAR counties?

Northern qualification on 7100 Single Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 33 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

### How much winter heat loss does 7100 Single Hung conduct across a 15 sq ft opening?

Using NFRC TTW U-Factor 0.23, a 15 sq ft Single-Hung (VSSH) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

### Who should NOT choose Thermo-Tech Windows 7100 Single Hung for a residential project?

Skip 7100 Single Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 7100 Single Hung options exceeding U 0.22.

### How many 7100 Single Hung glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 220 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Thermo-Tech Windows 7100 Single Hung, while total line SHGC reaches 0.49 in colder packages.

### Are all 257 7100 Single Hung configurations ENERGY STAR Most Efficient?

All 257 7100 Single Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Do 2026 7100 Single Hung installations qualify for IRS Section 25C tax credits?

Any 7100 Single Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify 7100 Single Hung glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line TTW-A-9 and NFRC ID TTW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thermo-Tech Windows 7100 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)