---
title: "Thompson Creek Window Company 7800 Fixed Specs (U 0.21)"
url: https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-fixed-414147/
description: "Thompson Creek Window Company 7800 Fixed (TCW-K-9, Picture Window, Vinyl): U-Factor 0.21-0.30, SHGC 0.18-0.29, 190 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC TCW · Product Line TCW-K-9 ENERGY STAR Most Efficient Eligible

# Thompson Creek Window Company — 7800 Fixed · Picture Window

EPA ENERGY STAR Version 7.0 certifies 190 variants inside Thompson Creek Window Company 7800 Fixed, combining Vinyl frame construction with U-Factors spanning 0.21 to 0.30 and SHGC 0.18 to 0.29. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #742 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.18-0.29

- **Certified Options** : 190

- **Category Standing** : #742 of 1,352

## How does Thompson Creek Window Company 7800 Fixed compare thermally against Window peers?

Thompson Creek Window Company 7800 Fixed achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 7800 Fixed is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.30.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 33 configurations meet ENERGY STAR Most Efficient criteria while 69 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors TCW to 2026-01-21 certification (FENSTAR issued 2018-09-05). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 126.0 BTU/hr conductive loss (-4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 190 certified glazing combinations for 7800 Fixed (NFRC TCW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 69 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 137 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 72 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 120 packages (33 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Northeast Windows USA, Inc.** — SL4011 Slider](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-sl4011-slider-413809/) | Vinyl | 0.21 | 0.09 | 212 |
| [**United Window & Door Mfg., Inc.** — 9600 Double Hung](https://ela-ecolandscapingassn.org/windows/models/united-window-door-mfg-inc-9600-double-hung-414212/) | Vinyl | 0.21 | 0.14 | 168 |
| [**Pella Corporation** — 250 Series / Power Symphony Double Hung](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-double-hung-413895/) | Vinyl | 0.21 | 0.17 | 217 |
| [**Krestmark Industries L. P.** — 250 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/krestmark-industries-l-p-250-fixed-window-413508/) | Vinyl | 0.21 | 0.16 | 224 |
| [**Northeast Windows USA, Inc.** — AW300 Awning](https://ela-ecolandscapingassn.org/windows/models/northeast-windows-usa-inc-aw300-awning-413812/) | Vinyl | 0.21 | 0.08 | 240 |

## What other certified series does Thompson Creek Window Company produce?

Compare other active Thompson Creek Window Company certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.17

### [7900 Fixed](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-fixed-414148/)

U-Factor 0.17–0.28 · 134 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-fixed-414148/)

Double HungMin U 0.20

### [7900 Double Hung](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-double-hung-414149/)

U-Factor 0.20–0.30 · 88 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-double-hung-414149/)

Double SliderMin U 0.21

### [7900 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-horizontal-slider-414150/)

U-Factor 0.21–0.30 · 121 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7900-horizontal-slider-414150/)

Single HungMin U 0.23

### [7800 Single Hung](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-single-hung-414145/)

U-Factor 0.23–0.31 · 242 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-single-hung-414145/)

Double HungMin U 0.24

### [7800 Double Hung](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-double-hung-414144/)

U-Factor 0.24–0.29 · 132 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-double-hung-414144/)

Single SliderMin U 0.24

### [7800 Single Slider](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-single-slider-414146/)

U-Factor 0.24–0.31 · 256 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/thompson-creek-window-company-7800-single-slider-414146/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Thompson Creek Window Company 7800 Fixed appear below.

### What U-Factor and SHGC range does Thompson Creek Window Company 7800 Fixed achieve?

Testing puts Thompson Creek Window Company 7800 Fixed at rank #742 of 1,352 Window entries with U 0.21 to 0.30 across 190 configurations. Solar heat gain ranges between 0.18 and 0.29 across Northern, North-Central, South-Central, Southern.

### Which glazing options in Thompson Creek Window Company 7800 Fixed meet Northern climate limits?

Thompson Creek Window Company 7800 Fixed supplies 69 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.30, so inspect the NFRC order sheet before purchase.

### How do you calculate winter heat conduction for Thompson Creek Window Company 7800 Fixed?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose Thompson Creek Window Company 7800 Fixed for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 7800 Fixed options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### What Southern ENERGY STAR v7.0 options exist in 7800 Fixed?

Warm-climate homeowners have 120 Southern-approved options within 7800 Fixed spanning SHGC down to 0.18. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Are all 190 7800 Fixed configurations ENERGY STAR Most Efficient?

Within 7800 Fixed, 17.4% (33 of 190) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### What federal compliance checks govern 2026 7800 Fixed window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on 7800 Fixed?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code TCW and product line TCW-K-9, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Thompson Creek Window Company 7800 Fixed come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
