title: "Value Windows & Doors AUC-XO Horizontal Slider Specs"
url: https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-auc-xo-horizontal-slider-414283/
description: "Value Windows & Doors AUC-XO Horizontal Slider (VWS-A-58, Single Slider, Aluminum): U-Factor 0.26-0.28, SHGC 0.13-0.18, 20 options across 2 ENERGY STAR."
---

Window · Aluminum Frame NFRC VWS · Product Line VWS-A-58

# Value Windows & Doors — AUC-XO Horizontal Slider · Single Slider

Across 16 Value Windows & Doors certified families, AUC-XO Horizontal Slider supplies 20 Single Slider configurations starting at 0.26 U-Factor and 0.13 SHGC for South-Central, Southern, reaching up to 0.28 U-Factor and 0.18 SHGC. Its thermal floor ranks #1,256 of 1,352 category entries—0.06 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.26

- **SHGC Range** : 0.13-0.18

- **Certified Options** : 20

- **Category Standing** : #1,256 of 1,352

## How does Value Windows & Doors AUC-XO Horizontal Slider compare thermally against Window peers?

Value Windows & Doors AUC-XO Horizontal Slider achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across AUC-XO Horizontal Slider spans 20 NFRC test records (VWS), ranking #1,256 of 1,352 Window families (tied with 35 others at 0.26, more insulating than 4.5% of Window lines). Its 0.26 thermal floor compares at +0.03 against the Aluminum median (0.23).

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2019-01-31 and v7.0 data certification on 2024-07-30. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.26 conducts 156.0 BTU/hr (+24.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 20 certified glazing combinations for AUC-XO Horizontal Slider (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 20 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 20 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**ESWindows LLC** — ES-LG250 Casement Window](https://ela-ecolandscapingassn.org/windows/models/eswindows-llc-es-lg250-casement-window-413215/) | Aluminum | 0.26 | 0.09 | 333 |
| [**Star Windows** — 9230 Single Hung](https://ela-ecolandscapingassn.org/windows/models/star-windows-9230-single-hung-414125/) | Vinyl | 0.26 | 0.20 | 17 |
| [**Neuma Door** — Outswing Transom](https://ela-ecolandscapingassn.org/windows/models/nan-ya-plastics-corporation-neuma-door-outswing-transom-413818/) | Composite | 0.26 | 0.17 | 13 |
| [**Neuma Door** — Inswing Transom](https://ela-ecolandscapingassn.org/windows/models/nan-ya-plastics-corporation-neuma-door-inswing-transom-413819/) | Composite | 0.26 | 0.17 | 12 |
| [**Comfort View Products, LLC** — 1920 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/comfort-view-products-llc-1920-horizontal-slider-413125/) | Vinyl | 0.26 | 0.20 | 33 |

## What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [EuroTek 70 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/)

U-Factor 0.15–0.29 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/)

Dual Action (Tilt Turn)Min U 0.17

### [EuroTek Tilt and Turn Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

U-Factor 0.17–0.27 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

Sliding Patio DoorMin U 0.18

### [IM/GX/GS Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/)

U-Factor 0.18–0.28 · 1,869 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/)

Picture WindowMin U 0.19

### [AL-CPW](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

U-Factor 0.19–0.32 · 68 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

Swinging Entry Door (Single)Min U 0.19

### [EuroTek Outswing Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

U-Factor 0.19–0.27 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

Casement WindowsMin U 0.19

### [Onyx Casement](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

U-Factor 0.19–0.31 · 281 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors AUC-XO Horizontal Slider appear below.

### Where does Value Windows & Doors AUC-XO Horizontal Slider stand thermally among ENERGY STAR Window lines?

Testing puts Value Windows & Doors AUC-XO Horizontal Slider at rank #1,256 of 1,352 Window entries with U 0.26 to 0.28 across 20 configurations. Solar heat gain ranges between 0.13 and 0.18 across South-Central, Southern.

### Does Value Windows & Doors AUC-XO Horizontal Slider qualify for the ENERGY STAR Northern Zone?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.26). Focus on South-Central, Southern glazing applications where SHGC 0.13-0.18 manages cooling loads.

### What BTU/hr heat transfer results from AUC-XO Horizontal Slider's 0.26 minimum U-Factor?

Using NFRC VWS U-Factor 0.26, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).

### What are the practical limitations of specifying AUC-XO Horizontal Slider?

Skip AUC-XO Horizontal Slider if local historic preservation boards prohibit Aluminum profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on AUC-XO Horizontal Slider options exceeding U 0.22.

### Is AUC-XO Horizontal Slider suitable for sunbelt cooling-dominated homes?

Yes, AUC-XO Horizontal Slider holds 20 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

### Which package tier in AUC-XO Horizontal Slider holds Most Efficient recognition?

AUC-XO Horizontal Slider holds zero Most Efficient entries across its 20 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

### Do 2026 AUC-XO Horizontal Slider installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current AUC-XO Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### Where are NFRC and IGCC identification marks located on AUC-XO Horizontal Slider?

Confirm both the paper NFRC label and permanent corner glass etch match line VWS-A-58 and NFRC ID VWS before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors AUC-XO Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)