title: "Value Windows & Doors EuroTek 70 Fixed Window Specs"
url: https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/
description: "Value Windows & Doors EuroTek 70 Fixed Window (VWS-A-49, Picture Window, Vinyl): U-Factor 0.15-0.29, SHGC 0.15-0.32, 219 options across 4 ENERGY STAR."
---

Window · Vinyl Frame NFRC VWS · Product Line VWS-A-49 ENERGY STAR Most Efficient Eligible

# Value Windows & Doors — EuroTek 70 Fixed Window · Picture Window

Value Windows & Doors engineered the EuroTek 70 Fixed Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 219 glass-spacer combinations from 0.15 to 0.29 U-Factor and 0.15 to 0.32 SHGC. Relative to other Vinyl models tracked under NFRC VWS, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.15

- **SHGC Range** : 0.15-0.32

- **Certified Options** : 219

- **Category Standing** : #136 of 1,352

## How does Value Windows & Doors EuroTek 70 Fixed Window compare thermally against Window peers?

Value Windows & Doors EuroTek 70 Fixed Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), EuroTek 70 Fixed Window is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.29.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 159 configurations meet ENERGY STAR Most Efficient criteria while 141 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-31 and cert timestamp 2024-05-07.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 219 certified glazing combinations for EuroTek 70 Fixed Window (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 141 packages (48 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 207 packages (102 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 168 packages (54 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 171 packages (111 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Mathews Brothers Company** — Sanford Hills Casement](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-casement-413661/) | Vinyl | 0.15 | 0.15 | 203 |
| [**North Star Manufacturing (London) Ltd.** — 1072 Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/north-star-manufacturing-london-ltd-1072-fixed-casement-413831/) | Vinyl | 0.15 | 0.15 | 200 |
| [**Mathews Brothers Company** — Sanford Hills Awning](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-awning-413662/) | Vinyl | 0.15 | 0.15 | 195 |
| [**Mercury Excelum, Inc.** — EOS\EOS+\ICON Fixed Casement](https://ela-ecolandscapingassn.org/windows/models/mercury-excelum-inc-eos-eos-icon-fixed-casement-413722/) | Vinyl | 0.15 | 0.17 | 179 |
| [**Vinylbilt Windows and Doors 2021 Inc** — Platinum/Diamond High Fixed](https://ela-ecolandscapingassn.org/windows/models/vinylbilt-windows-and-doors-2021-inc-platinum-diamond-high-fixed-414/) | Vinyl | 0.15 | 0.16 | 179 |

## What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Dual Action (Tilt Turn)Min U 0.17

### [EuroTek Tilt and Turn Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

U-Factor 0.17–0.27 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

Sliding Patio DoorMin U 0.18

### [IM/GX/GS Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/)

U-Factor 0.18–0.28 · 1,869 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/)

Picture WindowMin U 0.19

### [AL-CPW](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

U-Factor 0.19–0.32 · 68 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

Swinging Entry Door (Single)Min U 0.19

### [EuroTek Outswing Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

U-Factor 0.19–0.27 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

Casement WindowsMin U 0.19

### [Onyx Casement](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

U-Factor 0.19–0.31 · 281 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

Single HungMin U 0.19

### [Onyx/GSCO-SHT-2807](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-gsco-sht-2807-414285/)

U-Factor 0.19–0.32 · 777 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-gsco-sht-2807-414285/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors EuroTek 70 Fixed Window appear below.

### Where does Value Windows & Doors EuroTek 70 Fixed Window stand thermally among ENERGY STAR Window lines?

Testing puts Value Windows & Doors EuroTek 70 Fixed Window at rank #136 of 1,352 Window entries with U 0.15 to 0.29 across 219 configurations. Solar heat gain ranges between 0.15 and 0.32 across Northern, North-Central, South-Central, Southern.

### Can homeowners install EuroTek 70 Fixed Window in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 141 EuroTek 70 Fixed Window packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.29, specify the cold-climate glass code explicitly.

### How does a 3x5 ft EuroTek 70 Fixed Window window perform under a 40 deg F temperature drop?

At U 0.15, a standard 3x5 ft (15 sq ft) EuroTek 70 Fixed Window opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.

### What are the practical limitations of specifying EuroTek 70 Fixed Window?

Do not specify EuroTek 70 Fixed Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on EuroTek 70 Fixed Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does EuroTek 70 Fixed Window meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, EuroTek 70 Fixed Window holds 171 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

### Which package tier in EuroTek 70 Fixed Window holds Most Efficient recognition?

Within EuroTek 70 Fixed Window, 72.6% (159 of 219) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### Do 2026 EuroTek 70 Fixed Window installations qualify for IRS Section 25C tax credits?

Any EuroTek 70 Fixed Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How do building inspectors verify EuroTek 70 Fixed Window glass specs on job sites?

Verify NFRC ID VWS and series VWS-A-49 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors EuroTek 70 Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)