---
title: "Value Windows & Doors IM/GX/GS Sliding Patio Door"
url: https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/
description: "Value Windows & Doors IM/GX/GS Sliding Patio Door (VWS-A-10, Sliding Patio Door, Vinyl): U-Factor 0.18-0.28, SHGC 0.07-0.29, 1869 options across 4."
---

Door · Vinyl Frame NFRC VWS · Product Line VWS-A-10 ENERGY STAR Most Efficient Eligible

# Value Windows & Doors — IM/GX/GS Sliding Patio Door · Sliding Patio Door

With a minimum U-Factor of 0.18—-0.03 compared against the 0.21 Door median—Value Windows & Doors IM/GX/GS Sliding Patio Door spans 1,869 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code VWS, the Vinyl assembly includes 280 ENERGY STAR Most Efficient packages (15.0% of line) and offers SHGC packages between 0.07 and 0.29.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.07-0.29

- **Certified Options** : 1,869

- **Category Standing** : #75 of 268

## How does Value Windows & Doors IM/GX/GS Sliding Patio Door compare thermally against Door peers?

Value Windows & Doors IM/GX/GS Sliding Patio Door achieves a 0.18 thermal floor across Door lines, placing #75 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), IM/GX/GS Sliding Patio Door is 0.03 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.18-0.28.

Climate coverage for Value Windows & Doors IM/GX/GS Sliding Patio Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 280 configurations meet ENERGY STAR Most Efficient criteria while 1,262 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 108.0 BTU/hr (-18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-31 and cert timestamp 2025-09-18.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,869 certified glazing combinations for IM/GX/GS Sliding Patio Door (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 1,262 packages (0 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1,262 packages (154 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,677 packages (154 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 1,677 packages (280 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**DRUTEX S.A.** — IGLO 5 Inswing Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-inswing-door-413157/) | Vinyl | 0.18 | 0.12 | 1,602 |
| [**Vinylmax LLC** — PD3 Patio Door](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-pd3-patio-door-414256/) | Vinyl | 0.18 | 0.06 | 1,217 |
| [**DRUTEX S.A.** — IGLO 5 Classic Balcony Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-balcony-door-413153/) | Vinyl | 0.18 | 0.14 | 540 |
| [**MI Windows and Doors, LLC** — 1618 Polyvinyl Chloride (PVC) Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1618-polyvinyl-chloride-pvc-sliding-glass-d/) | Vinyl | 0.18 | 0.07 | 3,253 |
| [**Neuma Door** — Neuma Gliding Door](https://ela-ecolandscapingassn.org/windows/models/nan-ya-plastics-corporation-neuma-door-neuma-gliding-door-413816/) | Vinyl | 0.18 | 0.03 | 185 |

## What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [EuroTek 70 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/)

U-Factor 0.15–0.29 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/)

Dual Action (Tilt Turn)Min U 0.17

### [EuroTek Tilt and Turn Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

U-Factor 0.17–0.27 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

Picture WindowMin U 0.19

### [AL-CPW](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

U-Factor 0.19–0.32 · 68 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

Swinging Entry Door (Single)Min U 0.19

### [EuroTek Outswing Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

U-Factor 0.19–0.27 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

Casement WindowsMin U 0.19

### [Onyx Casement](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

U-Factor 0.19–0.31 · 281 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

Single HungMin U 0.19

### [Onyx/GSCO-SHT-2807](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-gsco-sht-2807-414285/)

U-Factor 0.19–0.32 · 777 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-gsco-sht-2807-414285/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors IM/GX/GS Sliding Patio Door appear below.

### What U-Factor and SHGC range does Value Windows & Doors IM/GX/GS Sliding Patio Door achieve?

Built with Vinyl framing in Sliding Glass Door (DDSG) style, Value Windows & Doors IM/GX/GS Sliding Patio Door offers 1,869 Version 7.0 configurations from U 0.18 up to 0.28, posting -0.03 against the Door median of 0.21 with 280 Most Efficient picks.

### Can homeowners install IM/GX/GS Sliding Patio Door in cold Northern ENERGY STAR counties?

Cold-climate buyers get 1,262 compliant Northern packages inside IM/GX/GS Sliding Patio Door, reaching down to U 0.18. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

### What conductive BTU/hr difference separates IM/GX/GS Sliding Patio Door from the 0.22 Northern rule?

At U 0.18, a standard 3x5 ft (15 sq ft) IM/GX/GS Sliding Patio Door opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.

### Which situations make IM/GX/GS Sliding Patio Door the wrong window or door choice?

Skip IM/GX/GS Sliding Patio Door if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IM/GX/GS Sliding Patio Door options exceeding U 0.22.

### Can you install Value Windows & Doors IM/GX/GS Sliding Patio Door in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 1,677 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Value Windows & Doors IM/GX/GS Sliding Patio Door, while total line SHGC reaches 0.29 in colder packages.

### Are all 1,869 IM/GX/GS Sliding Patio Door configurations ENERGY STAR Most Efficient?

EPA lists 280 Most Efficient options (15.0% share) inside Value Windows & Doors IM/GX/GS Sliding Patio Door, out of 1,869 total Version 7.0 entries.

### What 2026 federal tax credit and Lead RRP rules apply to IM/GX/GS Sliding Patio Door?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How can homeowners confirm delivered Value Windows & Doors IM/GX/GS Sliding Patio Door units match permits?

Verify NFRC ID VWS and series VWS-A-10 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors IM/GX/GS Sliding Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
