title: "Value Windows & Doors IM-XO-2101 Specs (U 0.26)"
url: https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-xo-2101-414273/
description: "Value Windows & Doors IM-XO-2101 (VWS-A-8, Single Slider, Vinyl): U-Factor 0.26-0.32, SHGC 0.13-0.23, 654 options across 2 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC VWS · Product Line VWS-A-8

# Value Windows & Doors — IM-XO-2101 · Single Slider

Positioning #1,256/1,352 in certified Window, Value Windows & Doors IM-XO-2101 pairs Vinyl frame construction with 654 glazing options rated between 0.13 and 0.23 SHGC across South-Central, Southern. Across 16 certified Value Windows & Doors product families, its thermal resistance spans 0.26 to 0.32 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.26

- **SHGC Range** : 0.13-0.23

- **Certified Options** : 654

- **Category Standing** : #1,256 of 1,352

## How does Value Windows & Doors IM-XO-2101 compare thermally against Window peers?

Value Windows & Doors IM-XO-2101 achieves a 0.26 thermal floor across Window lines, placing #1,256 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), IM-XO-2101 reaches 0.26 on its lowest-conductivity package — #957 of 1,009 in Vinyl, tied with 14 others at 0.26, more insulating than 3.8% of Vinyl lines (+0.07 vs Vinyl peers). Pairing NFRC ID VWS across multi-pane fills shifts U-Factor from 0.32 down toward 0.26.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 156.0 BTU/hr (+18.2% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-31 and cert timestamp 2026-11-02.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 654 certified glazing combinations for IM-XO-2101 (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 284 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 654 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**A Window, Inc.** — V85 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v85-horizontal-slider-413084/) | Vinyl | 0.26 | 0.16 | 429 |
| [**A Window, Inc.** — V85 Single Hung](https://ela-ecolandscapingassn.org/windows/models/a-window-inc-v85-single-hung-413083/) | Vinyl | 0.26 | 0.16 | 424 |
| [**Comfort View Products, LLC** — Series 1500 Casement](https://ela-ecolandscapingassn.org/windows/models/comfort-view-products-llc-series-1500-casement-413127/) | Vinyl | 0.26 | 0.16 | 195 |
| [**Custom Window Systems, Inc.** — 615/6150 Fixed](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-615-6150-fixed-413144/) | Vinyl | 0.26 | 0.14 | 144 |
| [**Pella Corporation** — Pella Defender Series - Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-pella-defender-series-fixed-413919/) | Vinyl | 0.26 | 0.14 | 144 |

## What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [EuroTek 70 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/)

U-Factor 0.15–0.29 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/)

Dual Action (Tilt Turn)Min U 0.17

### [EuroTek Tilt and Turn Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

U-Factor 0.17–0.27 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

Sliding Patio DoorMin U 0.18

### [IM/GX/GS Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/)

U-Factor 0.18–0.28 · 1,869 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/)

Picture WindowMin U 0.19

### [AL-CPW](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

U-Factor 0.19–0.32 · 68 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

Swinging Entry Door (Single)Min U 0.19

### [EuroTek Outswing Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

U-Factor 0.19–0.27 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

Casement WindowsMin U 0.19

### [Onyx Casement](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

U-Factor 0.19–0.31 · 281 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors IM-XO-2101 appear below.

### What thermal performance numbers separate Value Windows & Doors IM-XO-2101 from peers?

Testing puts Value Windows & Doors IM-XO-2101 at rank #1,256 of 1,352 Window entries with U 0.26 to 0.32 across 654 configurations. Solar heat gain ranges between 0.13 and 0.23 across South-Central, Southern.

### How does Value Windows & Doors IM-XO-2101 satisfy Version 7.0 Northern criteria?

Northern Zone certification is absent for IM-XO-2101 (0 qualifying options, min U 0.26). Install this Horizontal Slider (HSOX) product only within South-Central, Southern regions where lower SHGC caps apply.

### What conductive BTU/hr difference separates IM-XO-2101 from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), IM-XO-2101 at U 0.26 conducts 156.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Value Windows & Doors IM-XO-2101 for a residential project?

Skip IM-XO-2101 if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IM-XO-2101 options exceeding U 0.22.

### Is IM-XO-2101 suitable for sunbelt cooling-dominated homes?

Yes. 654 Southern-certified options inside Value Windows & Doors IM-XO-2101 satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.23 SHGC on west-facing glass to avoid excess afternoon solar gain.

### What glazing share inside IM-XO-2101 qualifies as Most Efficient?

No. Zero of the 654 configurations in Value Windows & Doors IM-XO-2101 hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### What 2026 federal tax credit and Lead RRP rules apply to IM-XO-2101?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify IM-XO-2101 after sticker removal?

Verify NFRC ID VWS and series VWS-A-8 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors IM-XO-2101 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)