title: "Value Windows & Doors Onyx/GSCO-SHT-2807 Specs"
url: https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-gsco-sht-2807-414285/
description: "Value Windows & Doors Onyx/GSCO-SHT-2807 (VWS-A-65, Single Hung, Vinyl): U-Factor 0.19-0.32, SHGC 0.08-0.22, 777 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC VWS · Product Line VWS-A-65 ENERGY STAR Most Efficient Eligible

# Value Windows & Doors — Onyx/GSCO-SHT-2807 · Single Hung

Value Windows & Doors engineered the Onyx/GSCO-SHT-2807 Single Hung line for Northern, North-Central, South-Central, Southern, certifying 777 glass-spacer combinations from 0.19 to 0.32 U-Factor and 0.08 to 0.22 SHGC. Relative to other Vinyl models tracked under NFRC VWS, its minimum U-Factor is matches the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.08-0.22

- **Certified Options** : 777

- **Category Standing** : #564 of 1,352

## How does Value Windows & Doors Onyx/GSCO-SHT-2807 compare thermally against Window peers?

Value Windows & Doors Onyx/GSCO-SHT-2807 achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Onyx/GSCO-SHT-2807 is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.19-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 145 configurations meet ENERGY STAR Most Efficient criteria while 41 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-31 and cert timestamp 2024-07-30.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 777 certified glazing combinations for Onyx/GSCO-SHT-2807 (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 41 packages (0 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 234 packages (48 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 417 packages (48 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 777 packages (145 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**WeatherBarr Windows and Doors** — Cornerstone/Heritage Picture Window](https://ela-ecolandscapingassn.org/windows/models/weatherbarr-windows-and-doors-cornerstone-heritage-picture-window-41/) | Vinyl | 0.19 | 0.17 | 710 |
| [**Lindsay Windows** — Climatesmart/Sunview/Crownview Single Slider](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-climatesmart-sunview-crownview-single-slider-413537/) | Vinyl | 0.19 | 0.17 | 879 |
| [**Lindsay Windows** — Pinnacle / Healthy Double Slider](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-pinnacle-healthy-double-slider-413536/) | Vinyl | 0.19 | 0.15 | 670 |
| [**Harvey Industries, Inc.** — Welded Vinyl Rolling Window](https://ela-ecolandscapingassn.org/windows/models/harvey-industries-inc-welded-vinyl-rolling-window-413304/) | Vinyl | 0.19 | 0.16 | 653 |
| [**Coeur D'Alene Window Company** — 3411 Casement Window](https://ela-ecolandscapingassn.org/windows/models/coeur-d-alene-window-company-3411-casement-window-413093/) | Vinyl | 0.19 | 0.10 | 542 |

## What other certified series does Value Windows & Doors produce?

Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [EuroTek 70 Fixed Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/)

U-Factor 0.15–0.29 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-70-fixed-window-414279/)

Dual Action (Tilt Turn)Min U 0.17

### [EuroTek Tilt and Turn Window](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

U-Factor 0.17–0.27 · 219 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-tilt-and-turn-window-414278/)

Sliding Patio DoorMin U 0.18

### [IM/GX/GS Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/)

U-Factor 0.18–0.28 · 1,869 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/)

Picture WindowMin U 0.19

### [AL-CPW](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

U-Factor 0.19–0.32 · 68 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-al-cpw-414281/)

Swinging Entry Door (Single)Min U 0.19

### [EuroTek Outswing Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

U-Factor 0.19–0.27 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-eurotek-outswing-door-414280/)

Casement WindowsMin U 0.19

### [Onyx Casement](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

U-Factor 0.19–0.31 · 281 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-onyx-casement-414287/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors Onyx/GSCO-SHT-2807 appear below.

### How well does Onyx/GSCO-SHT-2807 by Value Windows & Doors insulate relative to Window benchmarks?

Value Windows & Doors Onyx/GSCO-SHT-2807 spans 777 certified configurations with U-Factors between 0.19 and 0.32 and SHGC values from 0.08 to 0.22. Ranked #564 of 1,352 Window families, it carries 145 Most Efficient options.

### How does Value Windows & Doors Onyx/GSCO-SHT-2807 satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 41 compliant Northern packages inside Onyx/GSCO-SHT-2807, reaching down to U 0.19. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### How does a 3x5 ft Onyx/GSCO-SHT-2807 window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying Onyx/GSCO-SHT-2807?

Skip Onyx/GSCO-SHT-2807 if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Onyx/GSCO-SHT-2807 options exceeding U 0.22.

### What Southern ENERGY STAR v7.0 options exist in Onyx/GSCO-SHT-2807?

Warm-climate homeowners have 777 Southern-approved options within Onyx/GSCO-SHT-2807 spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Which package tier in Onyx/GSCO-SHT-2807 holds Most Efficient recognition?

No. Exactly 145 of 777 configurations (18.7%) earn ENERGY STAR Most Efficient status in Onyx/GSCO-SHT-2807; the remaining standard v7.0 options pass base zone limits only.

### What 2026 federal tax credit and Lead RRP rules apply to Onyx/GSCO-SHT-2807?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Onyx/GSCO-SHT-2807 installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do building inspectors verify Onyx/GSCO-SHT-2807 glass specs on job sites?

Verify NFRC ID VWS and series VWS-A-65 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors Onyx/GSCO-SHT-2807 come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)