title: "VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube Specs"
url: https://ela-ecolandscapingassn.org/windows/models/velux-tgf-tmf-velux-sun-tunnel-w-flex-tube-414239/
description: "VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube (VEL-N-15, Tubular Daylighting Device, Aluminum): U-Factor 0.26-0.45, SHGC 0.22-0.32, 4 options across 4 ENERGY."
---

Skylight · Aluminum Frame NFRC VEL · Product Line VEL-N-15 ENERGY STAR Most Efficient Eligible

# VELUX — TGF / TMF VELUX Sun Tunnel w/Flex Tube · Tubular Daylighting Device

EPA ENERGY STAR Version 7.0 certifies 4 variants inside VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube, combining Aluminum frame construction with U-Factors spanning 0.26 to 0.45 and SHGC 0.22 to 0.32. Qualifying for Northern, North-Central, South-Central, Southern, this Tubular Daylighting Device family places #1 of 16 among 16 Skylight families and posts 0.03 Btu/hr·ft²·°F less insulating than the 0.23 Btu/hr·ft²·°F median among Aluminum peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.26

- **SHGC Range** : 0.22-0.32

- **Certified Options** : 4

- **Category Standing** : #1 of 16

## How does VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube compare thermally against Skylight peers?

VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube achieves a 0.26 thermal floor across Skylight lines, placing #1 of 16 against the 0.35 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across TGF / TMF VELUX Sun Tunnel w/Flex Tube spans 4 NFRC test records (VEL), ranking #1 of 16 Skylight families (more insulating than 93.8% of Skylight lines, top 6.2%). Its 0.26 thermal floor compares at +0.03 against the Aluminum median (0.23).

Mapping NFRC SHGC values (0.22 to 0.32) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.26 U-Factor yields 156.0 BTU/hr transfer (+24.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2024-02-21 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4 certified glazing combinations for TGF / TMF VELUX Sun Tunnel w/Flex Tube (NFRC VEL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 4 packages (2 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 1 package (1 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1 package (1 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 1 package (1 Most Eff.) |

## Which competing Skylight series sit closest on U-Factor?

Inspect nearby Skylight competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**CrystaLite, Inc.** — 5830 Venting Skylight](https://ela-ecolandscapingassn.org/windows/models/crystalite-inc-5830-venting-skylight-413122/) | Vinyl | 0.28 | 0.14 | 146 |
| [**Columbia Manufacturing Co., Ltd.** — VSF Vinyl Self Flashing Skylight](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-vsf-vinyl-self-flashing-skylight-41311/) | Aluminum | 0.29 | 0.14 | 10 |
| [**CrystaLite, Inc.** — 5842 Fixed Skylight](https://ela-ecolandscapingassn.org/windows/models/crystalite-inc-5842-fixed-skylight-413123/) | Aluminum | 0.29 | 0.16 | 130 |
| [**VELUX** — FCM Fixed Curb Mounted Skylight](https://ela-ecolandscapingassn.org/windows/models/velux-fcm-fixed-curb-mounted-skylight-414243/) | Aluminum | 0.31 | 0.08 | 47 |
| [**Columbia Manufacturing Co., Ltd.** — GL VCM-IF Skylight](https://ela-ecolandscapingassn.org/windows/models/columbia-manufacturing-co-ltd-gl-vcm-if-skylight-413111/) | Aluminum | 0.32 | 0.13 | 10 |

## What other certified series does VELUX produce?

Compare other active VELUX certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

SkylightMin U 0.31

### [FCM Fixed Curb Mounted Skylight](https://ela-ecolandscapingassn.org/windows/models/velux-fcm-fixed-curb-mounted-skylight-414243/)

U-Factor 0.31–0.50 · 47 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/velux-fcm-fixed-curb-mounted-skylight-414243/)

SkylightMin U 0.34

### [QPF](https://ela-ecolandscapingassn.org/windows/models/velux-qpf-414242/)

U-Factor 0.34–0.45 · 31 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/velux-qpf-414242/)

SkylightMin U 0.36

### [VS/VSE/VSS](https://ela-ecolandscapingassn.org/windows/models/velux-vs-vse-vss-414240/)

U-Factor 0.36–0.44 · 17 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/velux-vs-vse-vss-414240/)

SkylightMin U 0.37

### [FS](https://ela-ecolandscapingassn.org/windows/models/velux-fs-414241/)

U-Factor 0.37–0.45 · 21 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/velux-fs-414241/)

Tubular Daylighting DeviceMin U 0.37

### [TCC / TCR / TGC / TGR / THR / TMR](https://ela-ecolandscapingassn.org/windows/models/velux-tcc-tcr-tgc-tgr-thr-tmr-414246/)

U-Factor 0.37–0.39 · 4 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/velux-tcc-tcr-tgc-tgr-thr-tmr-414246/)

Tubular Daylighting DeviceMin U 0.39

### [TLR VELUX Sun Tunnel w/Glass Top](https://ela-ecolandscapingassn.org/windows/models/velux-tlr-velux-sun-tunnel-w-glass-top-414245/)

U-Factor 0.39–0.39 · 1 certified option.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/velux-tlr-velux-sun-tunnel-w-glass-top-414245/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube appear below.

### How well does TGF / TMF VELUX Sun Tunnel w/Flex Tube by VELUX insulate relative to Skylight benchmarks?

Built with Aluminum framing in Tubular Daylighting Device (TDDY) style, VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube offers 4 Version 7.0 configurations from U 0.26 up to 0.45, posting -0.09 against the Skylight median of 0.35 with 2 Most Efficient picks.

### How does VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube satisfy Version 7.0 Northern criteria?

Prescriptive Northern approval ends at U <= 0.22, above TGF / TMF VELUX Sun Tunnel w/Flex Tube's 0.26 minimum. However, 4 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

### What conductive BTU/hr difference separates TGF / TMF VELUX Sun Tunnel w/Flex Tube from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.26 U-Factor yields 156.0 BTU/hr conductive transfer (+18.2% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube for a residential project?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on TGF / TMF VELUX Sun Tunnel w/Flex Tube options exceeding U 0.22. Verify whether your municipal code restricts Aluminum frames in wildfire or historic zones.

### How many TGF / TMF VELUX Sun Tunnel w/Flex Tube glazing packages pass Southern solar-heat rules?

Yes, TGF / TMF VELUX Sun Tunnel w/Flex Tube holds 1 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.22 SHGC in cooling climates.

### Does TGF / TMF VELUX Sun Tunnel w/Flex Tube carry EPA Most Efficient certification across its lineup?

Only 2 options out of 4 (50.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube, usually requiring triple-pane or upgraded Low-E coatings.

### How do the 25C sunset and pre-1978 Lead RRP rules affect TGF / TMF VELUX Sun Tunnel w/Flex Tube?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 TGF / TMF VELUX Sun Tunnel w/Flex Tube installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do building inspectors verify TGF / TMF VELUX Sun Tunnel w/Flex Tube glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.26-0.45, SHGC 0.22-0.32) against permit drawings for line VEL-N-15. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for VELUX TGF / TMF VELUX Sun Tunnel w/Flex Tube come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)