title: "Vinyl Kraft Prestige/Series 900 Patio Door Specs (U 0.21)"
url: https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-prestige-series-900-patio-door-414231/
description: "Vinyl Kraft Prestige/Series 900 Patio Door (VCI-K-24, Sliding Patio Door, Vinyl): U-Factor 0.21-0.28, SHGC 0.17-0.29, 20 options across 4 ENERGY STAR zones."
---

Door · Vinyl Frame NFRC VCI · Product Line VCI-K-24 ENERGY STAR Most Efficient Eligible

# Vinyl Kraft, Inc. — Prestige/Series 900 Patio Door · Sliding Patio Door

Positioning #133/268 in certified Door, Vinyl Kraft, Inc. Prestige/Series 900 Patio Door pairs Vinyl frame construction with 20 glazing options rated between 0.17 and 0.29 SHGC across Northern, North-Central, South-Central, Southern. Across 8 certified Vinyl Kraft, Inc. product families, its thermal resistance spans 0.21 to 0.28 U-Factor and the line includes 4 ENERGY STAR Most Efficient packages (20.0% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.17-0.29

- **Certified Options** : 20

- **Category Standing** : #133 of 268

## How does Vinyl Kraft, Inc. Prestige/Series 900 Patio Door compare thermally against Door peers?

Vinyl Kraft, Inc. Prestige/Series 900 Patio Door achieves a 0.21 thermal floor across Door lines, placing #133 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Vinyl Kraft, Inc. Prestige/Series 900 Patio Door at rank #133 of 268 (tied with 11 others at 0.21, more insulating than 46.3% of Door lines; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.17-0.29 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 4 configurations meet ENERGY STAR Most Efficient criteria while 16 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-10-03 and cert timestamp 2024-10-23.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 20 certified glazing combinations for Prestige/Series 900 Patio Door (NFRC VCI) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 16 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 16 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 14 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 14 packages (4 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Pella Corporation** — 150 Encompass Avanti](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-150-encompass-avanti-413893/) | Vinyl | 0.21 | 0.20 | 36 |
| [**Mathews Brothers Company** — Walcott Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-walcott-sliding-patio-door-413669/) | Vinyl | 0.21 | 0.20 | 48 |
| [**P H Tech Corp** — S-8375 Multi-Track Patio Door](https://ela-ecolandscapingassn.org/windows/models/p-h-tech-corp-s-8375-multi-track-patio-door-413929/) | Vinyl | 0.21 | 0.11 | 79 |
| [**ESWindows LLC** — ES-V76 Side Hinged Door](https://ela-ecolandscapingassn.org/windows/models/eswindows-llc-es-v76-side-hinged-door-413220/) | Vinyl | 0.21 | 0.10 | 99 |
| [**Seaway Manufacturing Corporation** — Grandview Patio Door](https://ela-ecolandscapingassn.org/windows/models/seaway-manufacturing-corporation-grandview-patio-door-414117/) | Vinyl | 0.21 | 0.12 | 129 |

## What other certified series does Vinyl Kraft, Inc. produce?

Compare other active Vinyl Kraft, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.18

### [Legacy / Heritage / 900 / 9230 PW](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-legacy-heritage-900-9230-pw-414228/)

U-Factor 0.18–0.27 · 36 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-legacy-heritage-900-9230-pw-414228/)

Double HungMin U 0.18

### [Legacy/Heritage/NR900/900NC/Obsidian DH](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-legacy-heritage-nr900-900nc-obsidian-dh-414229/)

U-Factor 0.18–0.28 · 48 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-legacy-heritage-nr900-900nc-obsidian-dh-414229/)

Double HungMin U 0.18

### [TRUSTGARD / 5500 / 5300 / 5200 DH](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trustgard-5500-5300-5200-dh-414224/)

U-Factor 0.18–0.29 · 124 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trustgard-5500-5300-5200-dh-414224/)

Single HungMin U 0.19

### [2000/2500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-2000-2500-single-hung-414227/)

U-Factor 0.19–0.29 · 68 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-2000-2500-single-hung-414227/)

Double SliderMin U 0.21

### [TrustGard Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trustgard-horizontal-slider-414225/)

U-Factor 0.21–0.28 · 76 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trustgard-horizontal-slider-414225/)

Single SliderMin U 0.22

### [Trust VK2000/2500 Single Slider](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trust-vk2000-2500-single-slider-414226/)

U-Factor 0.22–0.28 · 48 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trust-vk2000-2500-single-slider-414226/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinyl Kraft, Inc. Prestige/Series 900 Patio Door appear below.

### What U-Factor and SHGC range does Vinyl Kraft, Inc. Prestige/Series 900 Patio Door achieve?

EPA ENERGY STAR v7.0 records 20 configurations for Vinyl Kraft, Inc. Prestige/Series 900 Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.21 Door median. Only 4 options earn Most Efficient status.

### Can homeowners install Prestige/Series 900 Patio Door in cold Northern ENERGY STAR counties?

Yes, 16 packages satisfy Northern ENERGY STAR Version 7.0 rules in Prestige/Series 900 Patio Door. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### How does a 3x5 ft Prestige/Series 900 Patio Door window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying Prestige/Series 900 Patio Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Prestige/Series 900 Patio Door options exceeding U 0.22. Additionally, do not order Sliding Glass Door (DDSG) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Is Prestige/Series 900 Patio Door suitable for sunbelt cooling-dominated homes?

Yes. 14 Southern-certified options inside Vinyl Kraft, Inc. Prestige/Series 900 Patio Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.29 SHGC on west-facing glass to avoid excess afternoon solar gain.

### What glazing share inside Prestige/Series 900 Patio Door qualifies as Most Efficient?

Within Prestige/Series 900 Patio Door, 20.0% (4 of 20) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Prestige/Series 900 Patio Door?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Prestige/Series 900 Patio Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### Where are NFRC and IGCC identification marks located on Prestige/Series 900 Patio Door?

Confirm both the paper NFRC label and permanent corner glass etch match line VCI-K-24 and NFRC ID VCI before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinyl Kraft, Inc. Prestige/Series 900 Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)