title: "Vinylmax DHA4 Double Hung Specs (U 0.17) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dha4-double-hung-414264/
description: "Vinylmax DHA4 Double Hung (VIM-M-46, Double Hung, Vinyl): U-Factor 0.17-0.32, SHGC 0.14-0.49, 7745 options across 4 ENERGY STAR zones. Verified against."
---

Window · Vinyl Frame NFRC VIM · Product Line VIM-M-46 ENERGY STAR Most Efficient Eligible

# Vinylmax LLC — DHA4 Double Hung · Double Hung

Vinylmax LLC engineered the DHA4 Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 7,745 glass-spacer combinations from 0.17 to 0.32 U-Factor and 0.14 to 0.49 SHGC. Relative to other Vinyl models tracked under NFRC VIM, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.14-0.49

- **Certified Options** : 7,745

- **Category Standing** : #362 of 1,352

## How does Vinylmax LLC DHA4 Double Hung compare thermally against Window peers?

Vinylmax LLC DHA4 Double Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 12 certified Vinylmax LLC series, this Double Hung offers a 0.15 U-Factor adjustment span between 0.32 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 1,685 configurations meet ENERGY STAR Most Efficient criteria while 3,124 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2023-12-21.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,745 certified glazing combinations for DHA4 Double Hung (NFRC VIM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 3,124 packages (663 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 4,470 packages (936 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 3,560 packages (685 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 4,540 packages (1,297 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**PGT Industries** — HR5410/5510](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-hr5410-5510-413921/) | Vinyl | 0.17 | 0.08 | 8,277 |
| [**Wincore Window Company, LLC** — 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin/) | Vinyl | 0.17 | 0.08 | 6,278 |
| [**Wincore Window Company, LLC** — 5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin-414335/) | Vinyl | 0.17 | 0.08 | 6,256 |
| [**Wincore Window Company, LLC** — 7700, 9900 Basement Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-7700-9900-basement-window-414340/) | Vinyl | 0.17 | 0.08 | 6,256 |
| [**PGT Industries** — SH5400/5500](https://ela-ecolandscapingassn.org/windows/models/pgt-industries-sh5400-5500-413924/) | Vinyl | 0.17 | 0.09 | 9,241 |

## What other certified series does Vinylmax LLC produce?

Compare other active Vinylmax LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single HungMin U 0.16

### [A4 Single Hung](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-hung-414266/)

U-Factor 0.16–0.32 · 3,907 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-hung-414266/)

Single SliderMin U 0.16

### [A4 Single Slider](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-slider-414267/)

U-Factor 0.16–0.32 · 4,620 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-slider-414267/)

Picture WindowMin U 0.17

### [CP74 Picture Window](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-cp74-picture-window-414263/)

U-Factor 0.17–0.32 · 1,603 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-cp74-picture-window-414263/)

Double SliderMin U 0.17

### [DSA4 Double Slider](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dsa4-double-slider-414265/)

U-Factor 0.17–0.32 · 2,757 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dsa4-double-slider-414265/)

Awning (Projected)Min U 0.18

### [CA55/CA74 Awning](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-ca55-ca74-awning-414258/)

U-Factor 0.18–0.32 · 2,697 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-ca55-ca74-awning-414258/)

Casement WindowsMin U 0.18

### [CA55/CA74 Casement](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-ca55-ca74-casement-414257/)

U-Factor 0.18–0.32 · 3,415 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-ca55-ca74-casement-414257/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinylmax LLC DHA4 Double Hung appear below.

### How efficient is Vinylmax LLC DHA4 Double Hung compared with peer Window models?

Testing puts Vinylmax LLC DHA4 Double Hung at rank #362 of 1,352 Window entries with U 0.17 to 0.32 across 7,745 configurations. Solar heat gain ranges between 0.14 and 0.49 across Northern, North-Central, South-Central, Southern.

### How does Vinylmax LLC DHA4 Double Hung satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 3,124 DHA4 Double Hung packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

### How does a 3x5 ft DHA4 Double Hung window perform under a 40 deg F temperature drop?

Using NFRC VIM U-Factor 0.17, a 15 sq ft Double-Hung (VSDH) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

### What homeowner profiles are a poor match for Vinylmax LLC DHA4 Double Hung?

Do not specify DHA4 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on DHA4 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in DHA4 Double Hung?

Exactly 4,540 DHA4 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.49 glass.

### Are all 7,745 DHA4 Double Hung configurations ENERGY STAR Most Efficient?

Only 1,685 options out of 7,745 (21.8%) meet tighter Most Efficient U-Factor and SHGC thresholds in Vinylmax LLC DHA4 Double Hung, usually requiring triple-pane or upgraded Low-E coatings.

### What federal compliance checks govern 2026 DHA4 Double Hung window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 DHA4 Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How can homeowners confirm delivered Vinylmax LLC DHA4 Double Hung units match permits?

Inspectors match the temporary NFRC sticker (U 0.17-0.32, SHGC 0.14-0.49) against permit drawings for line VIM-M-46. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinylmax LLC DHA4 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)