Door · Vinyl Frame NFRC VIM · Product Line VIM-M-10 ENERGY STAR Most Efficient Eligible

# Vinylmax LLC — PD3 Patio Door · Sliding Patio Door

Vinylmax LLC PD3 Patio Door is a Sliding Patio Door assembly with a Vinyl frame that reaches a minimum U-Factor of 0.18 across 1,217 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #75 of 268 in Door, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.06 to 0.40.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.06-0.40

- **Certified Options** : 1,217

- **Category Standing** : #75 of 268

## How does Vinylmax LLC PD3 Patio Door compare thermally against Door peers?

Vinylmax LLC PD3 Patio Door achieves a 0.18 thermal floor across Door lines, placing #75 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 12 certified Vinylmax LLC series, this Sliding Patio Door offers a 0.10 U-Factor adjustment span between 0.28 entry options and 0.18 top-performing glazing. Category standing is #75/268 (tied with 18 others at 0.18, more insulating than 65.3% of Door lines, top 34.7%).

Climate coverage for Vinylmax LLC PD3 Patio Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 195 configurations meet ENERGY STAR Most Efficient criteria while 990 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-21. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.18 conducts 108.0 BTU/hr (-24.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,217 certified glazing combinations for PD3 Patio Door (NFRC VIM) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 990 packages (50 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 990 packages (91 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 766 packages (72 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 766 packages (176 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**DRUTEX S.A.** — IGLO 5 Inswing Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-inswing-door-413157/) | Vinyl | 0.18 | 0.12 | 1,602 |
| [**Value Windows & Doors** — IM/GX/GS Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-im-gx-gs-sliding-patio-door-414274/) | Vinyl | 0.18 | 0.07 | 1,869 |
| [**DRUTEX S.A.** — IGLO 5 Classic Balcony Door](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-5-classic-balcony-door-413153/) | Vinyl | 0.18 | 0.14 | 540 |
| [**Neuma Door** — Neuma Gliding Door](https://ela-ecolandscapingassn.org/windows/models/nan-ya-plastics-corporation-neuma-door-neuma-gliding-door-413816/) | Vinyl | 0.18 | 0.03 | 185 |
| [**Mathews Brothers Company** — Sanford Hills Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/mathews-brothers-company-sanford-hills-sliding-patio-door-413668/) | Vinyl | 0.18 | 0.17 | 124 |

## What other certified series does Vinylmax LLC produce?

Compare other active Vinylmax LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Single HungMin U 0.16

### [A4 Single Hung](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-hung-414266/)

U-Factor 0.16–0.32 · 3,907 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-hung-414266/)

Single SliderMin U 0.16

### [A4 Single Slider](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-slider-414267/)

U-Factor 0.16–0.32 · 4,620 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-a4-single-slider-414267/)

Picture WindowMin U 0.17

### [CP74 Picture Window](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-cp74-picture-window-414263/)

U-Factor 0.17–0.32 · 1,603 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-cp74-picture-window-414263/)

Double HungMin U 0.17

### [DHA4 Double Hung](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dha4-double-hung-414264/)

U-Factor 0.17–0.32 · 7,745 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dha4-double-hung-414264/)

Double SliderMin U 0.17

### [DSA4 Double Slider](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dsa4-double-slider-414265/)

U-Factor 0.17–0.32 · 2,757 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-dsa4-double-slider-414265/)

Awning (Projected)Min U 0.18

### [CA55/CA74 Awning](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-ca55-ca74-awning-414258/)

U-Factor 0.18–0.32 · 2,697 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-ca55-ca74-awning-414258/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinylmax LLC PD3 Patio Door appear below.

### What thermal performance numbers separate Vinylmax LLC PD3 Patio Door from peers?

EPA ENERGY STAR v7.0 records 1,217 configurations for Vinylmax LLC PD3 Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.18 versus a 0.21 Door median. Only 195 options earn Most Efficient status.

### Which glazing options in Vinylmax LLC PD3 Patio Door meet Northern climate limits?

Yes. 990 packages in Vinylmax LLC PD3 Patio Door clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

### How do you calculate winter heat conduction for Vinylmax LLC PD3 Patio Door?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), PD3 Patio Door at U 0.18 conducts 108.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying PD3 Patio Door?

Do not specify PD3 Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on PD3 Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### How many PD3 Patio Door glazing packages pass Southern solar-heat rules?

Yes, PD3 Patio Door holds 766 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.06 SHGC in cooling climates.

### Does PD3 Patio Door carry EPA Most Efficient certification across its lineup?

No. Exactly 195 of 1,217 configurations (16.0%) earn ENERGY STAR Most Efficient status in PD3 Patio Door; the remaining standard v7.0 options pass base zone limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect PD3 Patio Door?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 PD3 Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do you cross-check NFRC VIM and product line VIM-M-10 on delivery?

Inspectors match the temporary NFRC sticker (U 0.18-0.28, SHGC 0.06-0.40) against permit drawings for line VIM-M-10. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinylmax LLC PD3 Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)