title: "ViWinTech Window 2100 Single Slider Specs (U 0.28)"
url: https://ela-ecolandscapingassn.org/windows/models/viwintech-window-2100-single-slider-414268/
description: "ViWinTech Window 2100 Single Slider (VNL-M-32, Single Slider, Vinyl): U-Factor 0.28-0.32, SHGC 0.18-0.23, 87 options across 2 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC VNL · Product Line VNL-M-32

# ViWinTech Window — 2100 Single Slider · Single Slider

Across 2 ViWinTech Window certified families, 2100 Single Slider supplies 87 Single Slider configurations starting at 0.28 U-Factor and 0.18 SHGC for South-Central, Southern, reaching up to 0.32 U-Factor and 0.23 SHGC. Its thermal floor ranks #1,320 of 1,352 category entries—0.08 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.28

- **SHGC Range** : 0.18-0.23

- **Certified Options** : 87

- **Category Standing** : #1,320 of 1,352

## How does ViWinTech Window 2100 Single Slider compare thermally against Window peers?

ViWinTech Window 2100 Single Slider achieves a 0.28 thermal floor across Window lines, placing #1,320 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 2100 Single Slider is 0.08 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.28-0.32.

Regional qualification covers South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2026-01-22. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.28 conducts 168.0 BTU/hr (+36.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 87 certified glazing combinations for 2100 Single Slider (NFRC VNL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 19 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 87 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Value Windows & Doors** — Galaxy Single Slider](https://ela-ecolandscapingassn.org/windows/models/value-windows-doors-galaxy-single-slider-414275/) | Vinyl | 0.28 | 0.19 | 87 |
| [**L.A.S. Enterprises** — Weathergard II - Vinyl Single Hung](https://ela-ecolandscapingassn.org/windows/models/l-a-s-enterprises-weathergard-ii-vinyl-single-hung-413525/) | Vinyl | 0.28 | 0.14 | 60 |
| [**All America Windows LLC** — 1900 Series Single Hung](https://ela-ecolandscapingassn.org/windows/models/all-america-windows-llc-1900-series-single-hung-412850/) | Vinyl | 0.28 | 0.19 | 36 |
| [**Duke Vinyl Windows** — Marquis Double Hung](https://ela-ecolandscapingassn.org/windows/models/duke-vinyl-windows-marquis-double-hung-413186/) | Vinyl | 0.28 | 0.19 | 12 |
| [**Duke Vinyl Windows** — Marquis Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/duke-vinyl-windows-marquis-horizontal-slider-413185/) | Vinyl | 0.28 | 0.19 | 12 |

## What other certified series does ViWinTech Window produce?

Compare other active ViWinTech Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Casement WindowsMin U 0.27

### [Casement](https://ela-ecolandscapingassn.org/windows/models/viwintech-window-casement-414269/)

U-Factor 0.27–0.32 · 204 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/viwintech-window-casement-414269/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ViWinTech Window 2100 Single Slider appear below.

### How well does 2100 Single Slider by ViWinTech Window insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 87 configurations for ViWinTech Window 2100 Single Slider covering South-Central, Southern, dropping down to U 0.28 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### How does ViWinTech Window 2100 Single Slider satisfy Version 7.0 Northern criteria?

ViWinTech Window 2100 Single Slider holds zero Northern Zone qualifications (min U 0.28). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### What BTU/hr heat transfer results from 2100 Single Slider's 0.28 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 2100 Single Slider at U 0.28 conducts 168.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### When should a buyer skip ViWinTech Window 2100 Single Slider and compare alternatives?

Do not specify 2100 Single Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 2100 Single Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in 2100 Single Slider?

Exactly 87 2100 Single Slider options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.18 rather than higher 0.23 glass.

### What glazing share inside 2100 Single Slider qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 87 2100 Single Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What 2026 federal tax credit and Lead RRP rules apply to 2100 Single Slider?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 ViWinTech Window upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### Where are NFRC and IGCC identification marks located on 2100 Single Slider?

Inspectors match the temporary NFRC sticker (U 0.28-0.32, SHGC 0.18-0.23) against permit drawings for line VNL-M-32. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ViWinTech Window 2100 Single Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)