title: "Vytex 6000 Potomac Series Fixed Specs (U 0.14)"
url: https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/
description: "Vytex 6000 Potomac Series Fixed (VYW-A-46, Picture Window, Vinyl): U-Factor 0.14-0.27, SHGC 0.14-0.32, 316 options across 4 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC VYW · Product Line VYW-A-46 ENERGY STAR Most Efficient Eligible

# Vytex Corporation — 6000 Potomac Series Fixed · Picture Window

Across 18 Vytex Corporation certified families, 6000 Potomac Series Fixed supplies 316 Picture Window configurations starting at 0.14 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.27 U-Factor and 0.32 SHGC. Its thermal floor ranks #72 of 1,352 category entries—0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.14

- **SHGC Range** : 0.14-0.32

- **Certified Options** : 316

- **Category Standing** : #72 of 1,352

## How does Vytex Corporation 6000 Potomac Series Fixed compare thermally against Window peers?

Vytex Corporation 6000 Potomac Series Fixed achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 18 certified Vytex Corporation series, this Picture Window offers a 0.13 U-Factor adjustment span between 0.27 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 48 configurations meet ENERGY STAR Most Efficient criteria while 72 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors VYW to 2024-11-13 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 84.0 BTU/hr conductive loss (-36.4% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 316 certified glazing combinations for 6000 Potomac Series Fixed (NFRC VYW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 72 packages (20 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 280 packages (32 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 208 packages (28 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 208 packages (44 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Advanced Window Corp.** — EU 76 Septem Tilt Turn](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-eu-76-septem-tilt-turn-412866/) | Vinyl | 0.14 | 0.13 | 324 |
| [**Pella Corporation** — 250 Series / Power Symphony Fixed](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-250-series-power-symphony-fixed-413894/) | Vinyl | 0.14 | 0.18 | 266 |
| [**Vinyl Design Corporation** — Casement Deadlite](https://ela-ecolandscapingassn.org/windows/models/vinyl-design-corporation-casement-deadlite-414237/) | Vinyl | 0.14 | 0.18 | 263 |
| [**Advanced Window Corp.** — 6300 Picture Window](https://ela-ecolandscapingassn.org/windows/models/advanced-window-corp-6300-picture-window-412858/) | Vinyl | 0.14 | 0.18 | 408 |
| [**ProVia LLC** — Wood Clad Vinyl Picture Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-wood-clad-vinyl-picture-window-413944/) | Vinyl | 0.14 | 0.14 | 175 |

## What other certified series does Vytex Corporation produce?

Compare other active Vytex Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [3300 Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

U-Factor 0.13–0.24 · 78 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

Sliding Patio DoorMin U 0.14

### [8200 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

U-Factor 0.14–0.28 · 52 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

Casement WindowsMin U 0.16

### [3300 Casement](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

U-Factor 0.16–0.26 · 126 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

Double HungMin U 0.16

### [6000 Potomac Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

U-Factor 0.16–0.31 · 268 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

Double SliderMin U 0.16

### [6000 Potomac Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

U-Factor 0.16–0.30 · 248 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

Picture WindowMin U 0.20

### [Fortis Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-fortis-fixed-414297/)

U-Factor 0.20–0.25 · 50 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-fortis-fixed-414297/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vytex Corporation 6000 Potomac Series Fixed appear below.

### How well does 6000 Potomac Series Fixed by Vytex Corporation insulate relative to Window benchmarks?

Built with Vinyl framing in Fixed Window (FIXD) style, Vytex Corporation 6000 Potomac Series Fixed offers 316 Version 7.0 configurations from U 0.14 up to 0.27, posting -0.06 against the Window median of 0.20 with 48 Most Efficient picks.

### Does Vytex Corporation 6000 Potomac Series Fixed qualify for the ENERGY STAR Northern Zone?

Yes, 72 packages satisfy Northern ENERGY STAR Version 7.0 rules in 6000 Potomac Series Fixed. Pairing multi-pane insulation down to 0.14 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### What BTU/hr heat transfer results from 6000 Potomac Series Fixed's 0.14 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 6000 Potomac Series Fixed at U 0.14 conducts 84.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Who should NOT choose Vytex Corporation 6000 Potomac Series Fixed for a residential project?

Skip 6000 Potomac Series Fixed if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 6000 Potomac Series Fixed options exceeding U 0.22.

### Can you install Vytex Corporation 6000 Potomac Series Fixed in Southern or South-Central zones?

Yes. 208 Southern-certified options inside Vytex Corporation 6000 Potomac Series Fixed satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.32 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 316 6000 Potomac Series Fixed configurations ENERGY STAR Most Efficient?

Only 48 options out of 316 (15.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Vytex Corporation 6000 Potomac Series Fixed, usually requiring triple-pane or upgraded Low-E coatings.

### What 2026 federal tax credit and Lead RRP rules apply to 6000 Potomac Series Fixed?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Vytex Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How can homeowners confirm delivered Vytex Corporation 6000 Potomac Series Fixed units match permits?

Match the NFRC thermal sticker for code VYW and line VYW-A-46 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vytex Corporation 6000 Potomac Series Fixed come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)