title: "Vytex Fortis Double Hung Specs (U 0.21) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-fortis-double-hung-414299/
description: "Vytex Fortis Double Hung (VYW-A-50, Double Hung, Vinyl): U-Factor 0.21-0.26, SHGC 0.16-0.27, 68 options across 4 ENERGY STAR zones. Verified against federal."
---

Window · Vinyl Frame NFRC VYW · Product Line VYW-A-50 ENERGY STAR Most Efficient Eligible

# Vytex Corporation — Fortis Double Hung · Double Hung

Vytex Corporation Fortis Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.21 across 68 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #742 of 1,352 in Window, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.27.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.21

- **SHGC Range** : 0.16-0.27

- **Certified Options** : 68

- **Category Standing** : #742 of 1,352

## How does Vytex Corporation Fortis Double Hung compare thermally against Window peers?

Vytex Corporation Fortis Double Hung achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Fortis Double Hung is 0.01 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.21-0.26.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 19 configurations meet ENERGY STAR Most Efficient criteria while 19 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-11-17.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 68 certified glazing combinations for Fortis Double Hung (NFRC VYW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 19 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 64 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 48 packages (0 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 48 packages (19 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Wallside Windows** — ESTDS Double Slider](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-estds-double-slider-414317/) | Vinyl | 0.21 | 0.18 | 64 |
| [**Wallside Windows** — SDH Double Hung](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-sdh-double-hung-414318/) | Vinyl | 0.21 | 0.18 | 72 |
| [**Vinyl Kraft, Inc.** — TrustGard Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-trustgard-horizontal-slider-414225/) | Vinyl | 0.21 | 0.17 | 76 |
| [**MGM Industries** — 4600 Picture Window / Transom](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-4600-picture-window-transom-413726/) | Vinyl | 0.21 | 0.19 | 57 |
| [**United Window & Door Mfg., Inc.** — 9640 Picture Window](https://ela-ecolandscapingassn.org/windows/models/united-window-door-mfg-inc-9640-picture-window-414213/) | Vinyl | 0.21 | 0.17 | 81 |

## What other certified series does Vytex Corporation produce?

Compare other active Vytex Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [3300 Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

U-Factor 0.13–0.24 · 78 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

Picture WindowMin U 0.14

### [6000 Potomac Series Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/)

U-Factor 0.14–0.27 · 316 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/)

Sliding Patio DoorMin U 0.14

### [8200 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

U-Factor 0.14–0.28 · 52 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

Casement WindowsMin U 0.16

### [3300 Casement](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

U-Factor 0.16–0.26 · 126 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

Double HungMin U 0.16

### [6000 Potomac Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

U-Factor 0.16–0.31 · 268 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

Double SliderMin U 0.16

### [6000 Potomac Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

U-Factor 0.16–0.30 · 248 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vytex Corporation Fortis Double Hung appear below.

### What U-Factor and SHGC range does Vytex Corporation Fortis Double Hung achieve?

EPA ENERGY STAR v7.0 records 68 configurations for Vytex Corporation Fortis Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 19 options earn Most Efficient status.

### Which glazing options in Vytex Corporation Fortis Double Hung meet Northern climate limits?

Prescriptive Northern compliance covers 19 Fortis Double Hung packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.

### What BTU/hr heat transfer results from Fortis Double Hung's 0.21 minimum U-Factor?

At U 0.21, a standard 3x5 ft (15 sq ft) Fortis Double Hung opening transfers 126.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -6.0 BTU/hr difference.

### What homeowner profiles are a poor match for Vytex Corporation Fortis Double Hung?

Do not specify Fortis Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Fortis Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Can you install Vytex Corporation Fortis Double Hung in Southern or South-Central zones?

Yes. 48 Southern-certified options inside Vytex Corporation Fortis Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.27 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Which package tier in Fortis Double Hung holds Most Efficient recognition?

Only 19 options out of 68 (27.9%) meet tighter Most Efficient U-Factor and SHGC thresholds in Vytex Corporation Fortis Double Hung, usually requiring triple-pane or upgraded Low-E coatings.

### Can homeowners claim Form 5695 credits on Vytex Corporation Fortis Double Hung in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Fortis Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### What permanent glass etch marks verify Fortis Double Hung after sticker removal?

Verify NFRC ID VYW and series VYW-A-50 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vytex Corporation Fortis Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)