title: "Vytex Georgetown Double Hung Specs (U 0.27) | SillAndEave"
url: https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-georgetown-double-hung-414291/
description: "Vytex Georgetown Double Hung (VYW-A-41, Double Hung, Vinyl): U-Factor 0.27-0.32, SHGC 0.19-0.21, 16 options across 2 ENERGY STAR zones. Verified against."
---

Window · Vinyl Frame NFRC VYW · Product Line VYW-A-41

# Vytex Corporation — Georgetown Double Hung · Double Hung

Vytex Corporation Georgetown Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.27 across 16 certified glazing configurations covering South-Central, Southern. Ranked #1,292 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.19 to 0.21.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.27

- **SHGC Range** : 0.19-0.21

- **Certified Options** : 16

- **Category Standing** : #1,292 of 1,352

## How does Vytex Corporation Georgetown Double Hung compare thermally against Window peers?

Vytex Corporation Georgetown Double Hung achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Georgetown Double Hung is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.27-0.32.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.19 lowers cooling load.

Data provenance links certification 2024-03-05 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 162.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 16 certified glazing combinations for Georgetown Double Hung (NFRC VYW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 4 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 16 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Duke Vinyl Windows** — Marquis Casement](https://ela-ecolandscapingassn.org/windows/models/duke-vinyl-windows-marquis-casement-413189/) | Vinyl | 0.27 | 0.14 | 15 |
| [**Duke Vinyl Windows** — Marquis Picture Window](https://ela-ecolandscapingassn.org/windows/models/duke-vinyl-windows-marquis-picture-window-413188/) | Vinyl | 0.27 | 0.17 | 12 |
| [**Silver Line Building Products** — 2130 IMPACT Fixed Window](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-2130-impact-fixed-window-414092/) | Vinyl | 0.27 | 0.19 | 20 |
| [**Comfort View Products, LLC** — 1900 Vinyl Single Hung](https://ela-ecolandscapingassn.org/windows/models/comfort-view-products-llc-1900-vinyl-single-hung-413124/) | Vinyl | 0.27 | 0.20 | 21 |
| [**Walsh Building Products** — #4200 Single Slider](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-4200-single-slider-414314/) | Vinyl | 0.27 | 0.20 | 8 |

## What other certified series does Vytex Corporation produce?

Compare other active Vytex Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [3300 Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

U-Factor 0.13–0.24 · 78 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

Picture WindowMin U 0.14

### [6000 Potomac Series Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/)

U-Factor 0.14–0.27 · 316 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/)

Sliding Patio DoorMin U 0.14

### [8200 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

U-Factor 0.14–0.28 · 52 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

Casement WindowsMin U 0.16

### [3300 Casement](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

U-Factor 0.16–0.26 · 126 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

Double HungMin U 0.16

### [6000 Potomac Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

U-Factor 0.16–0.31 · 268 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

Double SliderMin U 0.16

### [6000 Potomac Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

U-Factor 0.16–0.30 · 248 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vytex Corporation Georgetown Double Hung appear below.

### What thermal performance numbers separate Vytex Corporation Georgetown Double Hung from peers?

Testing puts Vytex Corporation Georgetown Double Hung at rank #1,292 of 1,352 Window entries with U 0.27 to 0.32 across 16 configurations. Solar heat gain ranges between 0.19 and 0.21 across South-Central, Southern.

### Is Georgetown Double Hung approved for Northern Zone heating climates?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.27). Focus on South-Central, Southern glazing applications where SHGC 0.19-0.21 manages cooling loads.

### What BTU/hr heat transfer results from Georgetown Double Hung's 0.27 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 162.0 BTU/hr on Georgetown Double Hung's lowest-U package (0.27), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What are the practical limitations of specifying Georgetown Double Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Georgetown Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Can you install Vytex Corporation Georgetown Double Hung in Southern or South-Central zones?

Across South-Central, Southern, 16 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Vytex Corporation Georgetown Double Hung, while total line SHGC reaches 0.21 in colder packages.

### Which package tier in Georgetown Double Hung holds Most Efficient recognition?

Zero glazing builds inside Georgetown Double Hung's 16 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What federal compliance checks govern 2026 Georgetown Double Hung window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### What permanent glass etch marks verify Georgetown Double Hung after sticker removal?

Verify NFRC ID VYW and series VYW-A-41 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vytex Corporation Georgetown Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)