title: "Vytex Georgetown Horizontal Slider Specs (U 0.27)"
url: https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-georgetown-horizontal-slider-414289/
description: "Vytex Georgetown Horizontal Slider (VYW-A-38, Double Slider, Vinyl): U-Factor 0.27-0.32, SHGC 0.18-0.20, 16 options across 2 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC VYW · Product Line VYW-A-38

# Vytex Corporation — Georgetown Horizontal Slider · Double Slider

With a minimum U-Factor of 0.27—+0.07 compared against the 0.20 Window median—Vytex Corporation Georgetown Horizontal Slider spans 16 tested options across South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code VYW, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.18 and 0.20.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.27

- **SHGC Range** : 0.18-0.20

- **Certified Options** : 16

- **Category Standing** : #1,292 of 1,352

## How does Vytex Corporation Georgetown Horizontal Slider compare thermally against Window peers?

Vytex Corporation Georgetown Horizontal Slider achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Georgetown Horizontal Slider is 0.07 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.27-0.32.

Mapping NFRC SHGC values (0.18 to 0.20) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.18 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-03-05.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 16 certified glazing combinations for Georgetown Horizontal Slider (NFRC VYW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 4 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 16 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Duke Vinyl Windows** — Marquis Casement](https://ela-ecolandscapingassn.org/windows/models/duke-vinyl-windows-marquis-casement-413189/) | Vinyl | 0.27 | 0.14 | 15 |
| [**Duke Vinyl Windows** — Marquis Picture Window](https://ela-ecolandscapingassn.org/windows/models/duke-vinyl-windows-marquis-picture-window-413188/) | Vinyl | 0.27 | 0.17 | 12 |
| [**Silver Line Building Products** — 2130 IMPACT Fixed Window](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-2130-impact-fixed-window-414092/) | Vinyl | 0.27 | 0.19 | 20 |
| [**Comfort View Products, LLC** — 1900 Vinyl Single Hung](https://ela-ecolandscapingassn.org/windows/models/comfort-view-products-llc-1900-vinyl-single-hung-413124/) | Vinyl | 0.27 | 0.20 | 21 |
| [**Walsh Building Products** — #4200 Single Slider](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-4200-single-slider-414314/) | Vinyl | 0.27 | 0.20 | 8 |

## What other certified series does Vytex Corporation produce?

Compare other active Vytex Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [3300 Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

U-Factor 0.13–0.24 · 78 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

Picture WindowMin U 0.14

### [6000 Potomac Series Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/)

U-Factor 0.14–0.27 · 316 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/)

Sliding Patio DoorMin U 0.14

### [8200 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

U-Factor 0.14–0.28 · 52 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

Casement WindowsMin U 0.16

### [3300 Casement](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

U-Factor 0.16–0.26 · 126 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

Double HungMin U 0.16

### [6000 Potomac Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

U-Factor 0.16–0.31 · 268 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

Double SliderMin U 0.16

### [6000 Potomac Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

U-Factor 0.16–0.30 · 248 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vytex Corporation Georgetown Horizontal Slider appear below.

### How efficient is Vytex Corporation Georgetown Horizontal Slider compared with peer Window models?

Vytex Corporation Georgetown Horizontal Slider spans 16 certified configurations with U-Factors between 0.27 and 0.32 and SHGC values from 0.18 to 0.20. Ranked #1,292 of 1,352 Window families, it carries 0 Most Efficient options.

### Does Vytex Corporation Georgetown Horizontal Slider qualify for the ENERGY STAR Northern Zone?

Vytex Corporation Georgetown Horizontal Slider holds zero Northern Zone qualifications (min U 0.27). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### How does a 3x5 ft Georgetown Horizontal Slider window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 162.0 BTU/hr on Georgetown Horizontal Slider's lowest-U package (0.27), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### What are the practical limitations of specifying Georgetown Horizontal Slider?

Do not specify Georgetown Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Georgetown Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### Does Georgetown Horizontal Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 16 Georgetown Horizontal Slider options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.18 rather than higher 0.20 glass.

### Does Georgetown Horizontal Slider carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 16 Georgetown Horizontal Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### Do 2026 Georgetown Horizontal Slider installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Georgetown Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### Where are NFRC and IGCC identification marks located on Georgetown Horizontal Slider?

Verify NFRC ID VYW and series VYW-A-38 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vytex Corporation Georgetown Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)