description: "Vytex Grandview Double Hung (VYW-A-53, Double Hung, Vinyl): U-Factor 0.23-0.30, SHGC 0.19-0.28, 22 options across 3 ENERGY STAR zones. Verified against."
---

Window · Vinyl Frame NFRC VYW · Product Line VYW-A-53

# Vytex Corporation — Grandview Double Hung · Double Hung

Vytex Corporation Grandview Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.23 across 22 certified glazing configurations covering North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.19 to 0.28.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.23

- **SHGC Range** : 0.19-0.28

- **Certified Options** : 22

- **Category Standing** : #936 of 1,352

## How does Vytex Corporation Grandview Double Hung compare thermally against Window peers?

Vytex Corporation Grandview Double Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Grandview Double Hung is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.30.

Evaluating climate compliance across North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.19 lowers cooling load.

Lifecycle documentation anchors VYW to 2024-03-12 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 22 certified glazing combinations for Grandview Double Hung (NFRC VYW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 12 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 12 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 16 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Morfe Windows LLC** — Horizontal Sliding Window](https://ela-ecolandscapingassn.org/windows/models/morfe-windows-llc-horizontal-sliding-window-413791/) | Vinyl | 0.23 | 0.18 | 20 |
| [**Taylors Window and Screen, Inc.** — 8501 NC/Repl Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/taylors-window-and-screen-inc-8501-nc-repl-casement-picture-window-4/) | Vinyl | 0.23 | 0.18 | 18 |
| [**California Deluxe Windows Industries, Inc.** — S-3480 Single Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3480-single-hung-413096/) | Vinyl | 0.23 | 0.12 | 28 |
| [**California Deluxe Windows Industries, Inc.** — S-3555 Double Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3555-double-hung-413098/) | Vinyl | 0.23 | 0.11 | 28 |
| [**California Deluxe Windows Industries, Inc.** — S-3775/3785 Single Hung](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-3775-3785-single-hung-413/) | Vinyl | 0.23 | 0.12 | 28 |

## What other certified series does Vytex Corporation produce?

Compare other active Vytex Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.13

### [3300 Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

U-Factor 0.13–0.24 · 78 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-fixed-414300/)

Picture WindowMin U 0.14

### [6000 Potomac Series Fixed](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/)

U-Factor 0.14–0.27 · 316 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-fixed-414295/)

Sliding Patio DoorMin U 0.14

### [8200 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

U-Factor 0.14–0.28 · 52 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-8200-sliding-glass-door-414294/)

Casement WindowsMin U 0.16

### [3300 Casement](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

U-Factor 0.16–0.26 · 126 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-3300-casement-414303/)

Double HungMin U 0.16

### [6000 Potomac Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

U-Factor 0.16–0.31 · 268 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-double-hung-414293/)

Double SliderMin U 0.16

### [6000 Potomac Series Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

U-Factor 0.16–0.30 · 248 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-6000-potomac-series-horizontal-slider-414296/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vytex Corporation Grandview Double Hung appear below.

### What thermal performance numbers separate Vytex Corporation Grandview Double Hung from peers?

EPA ENERGY STAR v7.0 records 22 configurations for Vytex Corporation Grandview Double Hung covering North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Which glazing options in Vytex Corporation Grandview Double Hung meet Northern climate limits?

Northern Zone certification is absent for Grandview Double Hung (0 qualifying options, min U 0.23). Install this Double-Hung (VSDH) product only within North-Central, South-Central, Southern regions where lower SHGC caps apply.

### How does a 3x5 ft Grandview Double Hung window perform under a 40 deg F temperature drop?

Using NFRC VYW U-Factor 0.23, a 15 sq ft Double-Hung (VSDH) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

### What are the practical limitations of specifying Grandview Double Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Grandview Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Vytex Corporation Grandview Double Hung in Southern or South-Central zones?

Across North-Central, South-Central, Southern, 16 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Vytex Corporation Grandview Double Hung, while total line SHGC reaches 0.28 in colder packages.

### How many Vytex Corporation Grandview Double Hung variants earn ENERGY STAR Most Efficient?

No. Zero of the 22 configurations in Vytex Corporation Grandview Double Hung hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### Do 2026 Grandview Double Hung installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Vytex Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify Grandview Double Hung glass specs on job sites?

Match the NFRC thermal sticker for code VYW and line VYW-A-53 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vytex Corporation Grandview Double Hung come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)