title: "Wallside Windows PD2 Patio Door (Exterior Glazed) Specs"
url: https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pd2-patio-door-exterior-glazed-414316/
description: "Wallside Windows PD2 Patio Door (Exterior Glazed) (WAW-K-13, Sliding Patio Door, Vinyl): U-Factor 0.22-0.28, SHGC 0.19-0.29, 42 options across 4 ENERGY STAR."
---

Door · Vinyl Frame NFRC WAW · Product Line WAW-K-13

# Wallside Windows — PD2 Patio Door (Exterior Glazed) · Sliding Patio Door

Positioning #145/268 in certified Door, Wallside Windows PD2 Patio Door (Exterior Glazed) pairs Vinyl frame construction with 42 glazing options rated between 0.19 and 0.29 SHGC across Northern, North-Central, South-Central, Southern. Across 7 certified Wallside Windows product families, its thermal resistance spans 0.22 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.22

- **SHGC Range** : 0.19-0.29

- **Certified Options** : 42

- **Category Standing** : #145 of 268

## How does Wallside Windows PD2 Patio Door (Exterior Glazed) compare thermally against Door peers?

Wallside Windows PD2 Patio Door (Exterior Glazed) achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), PD2 Patio Door (Exterior Glazed) is 0.01 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.22-0.28.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 24 combinations qualify in the Northern Zone alongside 22 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-08-23 licensing and 2025-06-13 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 42 certified glazing combinations for PD2 Patio Door (Exterior Glazed) (NFRC WAW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 24 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 24 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 22 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 22 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**California Deluxe Windows Industries, Inc.** — S-6300 Tilt & Turn Door (Inswing)](https://ela-ecolandscapingassn.org/windows/models/california-deluxe-windows-industries-inc-s-6300-tilt-turn-door-inswi/) | Vinyl | 0.22 | 0.10 | 26 |
| [**P H Tech Corp** — S-7500 Patio Door](https://ela-ecolandscapingassn.org/windows/models/p-h-tech-corp-s-7500-patio-door-413928/) | Vinyl | 0.22 | 0.05 | 79 |
| [**Lindsay Windows** — 191 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/lindsay-windows-191-sliding-glass-door-413541/) | Vinyl | 0.22 | 0.15 | 132 |
| [**Interstate Building Materials, Inc.** — 9200 Patio Door](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-9200-patio-door-413319/) | Vinyl | 0.22 | 0.17 | 145 |
| [**MGM Industries** — 9000/9050 Sliding Glass Door](https://ela-ecolandscapingassn.org/windows/models/mgm-industries-9000-9050-sliding-glass-door-413727/) | Vinyl | 0.22 | 0.14 | 1,317 |

## What other certified series does Wallside Windows produce?

Compare other active Wallside Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.17

### [PC-V Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pc-v-casement-picture-window-414322/)

U-Factor 0.17–0.26 · 88 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pc-v-casement-picture-window-414322/)

Picture WindowMin U 0.18

### [PW - Picture Window](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pw-picture-window-414319/)

U-Factor 0.18–0.26 · 82 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pw-picture-window-414319/)

Awning (Projected)Min U 0.19

### [AC-V Awning](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-ac-v-awning-414321/)

U-Factor 0.19–0.26 · 55 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-ac-v-awning-414321/)

Casement WindowsMin U 0.19

### [SC-V Casement](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-sc-v-casement-414320/)

U-Factor 0.19–0.26 · 56 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-sc-v-casement-414320/)

Double SliderMin U 0.21

### [ESTDS Double Slider](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-estds-double-slider-414317/)

U-Factor 0.21–0.28 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-estds-double-slider-414317/)

Double HungMin U 0.21

### [SDH Double Hung](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-sdh-double-hung-414318/)

U-Factor 0.21–0.28 · 72 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-sdh-double-hung-414318/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wallside Windows PD2 Patio Door (Exterior Glazed) appear below.

### How well does PD2 Patio Door (Exterior Glazed) by Wallside Windows insulate relative to Door benchmarks?

Across 42 tested NFRC glazing configurations, Wallside Windows PD2 Patio Door (Exterior Glazed) with Vinyl framing and Sliding Glass Door (DDSG) style reaches a 0.22 minimum U-Factor and 0.19-0.29 SHGC band. It places #145 among 268 Door series—more insulating than 39.9%.

### How does Wallside Windows PD2 Patio Door (Exterior Glazed) satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 24 compliant Northern packages inside PD2 Patio Door (Exterior Glazed), reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

### How much winter heat loss does PD2 Patio Door (Exterior Glazed) conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 132.0 BTU/hr on PD2 Patio Door (Exterior Glazed)'s lowest-U package (0.22), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

### When should a buyer skip Wallside Windows PD2 Patio Door (Exterior Glazed) and compare alternatives?

Skip PD2 Patio Door (Exterior Glazed) if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on PD2 Patio Door (Exterior Glazed) options exceeding U 0.22.

### How many PD2 Patio Door (Exterior Glazed) glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 22 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Wallside Windows PD2 Patio Door (Exterior Glazed), while total line SHGC reaches 0.29 in colder packages.

### What glazing share inside PD2 Patio Door (Exterior Glazed) qualifies as Most Efficient?

Zero glazing builds inside PD2 Patio Door (Exterior Glazed)'s 42 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### What federal compliance checks govern 2026 PD2 Patio Door (Exterior Glazed) window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### How do building inspectors verify PD2 Patio Door (Exterior Glazed) glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.22-0.28, SHGC 0.19-0.29) against permit drawings for line WAW-K-13. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wallside Windows PD2 Patio Door (Exterior Glazed) come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)