Window · Vinyl Frame NFRC WAW · Product Line WAW-K-22 ENERGY STAR Most Efficient Eligible

# Wallside Windows — SC-V Casement · Casement Windows

Positioning #564/1,352 in certified Window, Wallside Windows SC-V Casement pairs Vinyl frame construction with 56 glazing options rated between 0.16 and 0.42 SHGC across Northern, North-Central, South-Central, Southern. Across 7 certified Wallside Windows product families, its thermal resistance spans 0.19 to 0.26 U-Factor and the line includes 18 ENERGY STAR Most Efficient packages (32.1% of line).

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.19

- **SHGC Range** : 0.16-0.42

- **Certified Options** : 56

- **Category Standing** : #564 of 1,352

## How does Wallside Windows SC-V Casement compare thermally against Window peers?

Wallside Windows SC-V Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), SC-V Casement reaches 0.19 on its lowest-conductivity package — #429 of 1,009 in Vinyl, tied with 83 others at 0.19, more insulating than 49.3% of Vinyl lines (At median vs Vinyl peers). Pairing NFRC ID WAW across multi-pane fills shifts U-Factor from 0.26 down toward 0.19.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 18 configurations meet ENERGY STAR Most Efficient criteria while 40 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-08-23 licensing and 2024-11-15 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 56 certified glazing combinations for SC-V Casement (NFRC WAW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 40 packages (9 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 46 packages (13 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 38 packages (13 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 38 packages (18 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Soft-Lite, LLC** — Elements DH20 Double Hung](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-elements-dh20-double-hung-414104/) | Vinyl | 0.19 | 0.16 | 68 |
| [**Soft-Lite, LLC** — Imperial Elite DH12E](https://ela-ecolandscapingassn.org/windows/models/soft-lite-llc-imperial-elite-dh12e-414115/) | Vinyl | 0.19 | 0.16 | 68 |
| [**Vinyl Kraft, Inc.** — 2000/2500 Single Hung](https://ela-ecolandscapingassn.org/windows/models/vinyl-kraft-inc-2000-2500-single-hung-414227/) | Vinyl | 0.19 | 0.17 | 68 |
| [**Northeast Building Products Corporation** — Elite DH PW](https://ela-ecolandscapingassn.org/windows/models/northeast-building-products-corporation-elite-dh-pw-413797/) | Vinyl | 0.19 | 0.17 | 76 |
| [**Northeast Building Products Corporation** — Elite NC PW](https://ela-ecolandscapingassn.org/windows/models/northeast-building-products-corporation-elite-nc-pw-413799/) | Vinyl | 0.19 | 0.16 | 77 |

## What other certified series does Wallside Windows produce?

Compare other active Wallside Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.17

### [PC-V Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pc-v-casement-picture-window-414322/)

U-Factor 0.17–0.26 · 88 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pc-v-casement-picture-window-414322/)

Picture WindowMin U 0.18

### [PW - Picture Window](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pw-picture-window-414319/)

U-Factor 0.18–0.26 · 82 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pw-picture-window-414319/)

Awning (Projected)Min U 0.19

### [AC-V Awning](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-ac-v-awning-414321/)

U-Factor 0.19–0.26 · 55 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-ac-v-awning-414321/)

Double SliderMin U 0.21

### [ESTDS Double Slider](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-estds-double-slider-414317/)

U-Factor 0.21–0.28 · 64 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-estds-double-slider-414317/)

Double HungMin U 0.21

### [SDH Double Hung](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-sdh-double-hung-414318/)

U-Factor 0.21–0.28 · 72 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-sdh-double-hung-414318/)

Sliding Patio DoorMin U 0.22

### [PD2 Patio Door (Exterior Glazed)](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pd2-patio-door-exterior-glazed-414316/)

U-Factor 0.22–0.28 · 42 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wallside-windows-pd2-patio-door-exterior-glazed-414316/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wallside Windows SC-V Casement appear below.

### What U-Factor and SHGC range does Wallside Windows SC-V Casement achieve?

Testing puts Wallside Windows SC-V Casement at rank #564 of 1,352 Window entries with U 0.19 to 0.26 across 56 configurations. Solar heat gain ranges between 0.16 and 0.42 across Northern, North-Central, South-Central, Southern.

### Is SC-V Casement approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 40 SC-V Casement packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.

### What conductive BTU/hr difference separates SC-V Casement from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), SC-V Casement at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying SC-V Casement?

Cold-climate owners needing prescriptive U <= 0.22 should pass on SC-V Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

### Can you install Wallside Windows SC-V Casement in Southern or South-Central zones?

Yes. 38 Southern-certified options inside Wallside Windows SC-V Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.42 SHGC on west-facing glass to avoid excess afternoon solar gain.

### What glazing share inside SC-V Casement qualifies as Most Efficient?

No. Exactly 18 of 56 configurations (32.1%) earn ENERGY STAR Most Efficient status in SC-V Casement; the remaining standard v7.0 options pass base zone limits only.

### Can homeowners claim Form 5695 credits on Wallside Windows SC-V Casement in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Wallside Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How do building inspectors verify SC-V Casement glass specs on job sites?

Confirm both the paper NFRC label and permanent corner glass etch match line WAW-K-22 and NFRC ID WAW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wallside Windows SC-V Casement come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)