title: "Walsh Building Products #4200 Single Slider Specs (U 0.27)"
url: https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-4200-single-slider-414314/
description: "Walsh Building Products #4200 Single Slider (WAL-K-30, Single Slider, Vinyl): U-Factor 0.27-0.30, SHGC 0.20-0.22, 8 options across 2 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC WAL · Product Line WAL-K-30

# Walsh Building Products — #4200 Single Slider · Single Slider

With a minimum U-Factor of 0.27—+0.07 compared against the 0.20 Window median—Walsh Building Products #4200 Single Slider spans 8 tested options across South-Central, Southern up to 0.30 U-Factor. Carrying NFRC CPD code WAL, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.20 and 0.22.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.27

- **SHGC Range** : 0.20-0.22

- **Certified Options** : 8

- **Category Standing** : #1,292 of 1,352

## How does Walsh Building Products #4200 Single Slider compare thermally against Window peers?

Walsh Building Products #4200 Single Slider achieves a 0.27 thermal floor across Window lines, placing #1,292 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across #4200 Single Slider spans 8 NFRC test records (WAL), ranking #1,292 of 1,352 Window families (tied with 27 others at 0.27, more insulating than 2.4% of Window lines). Its 0.27 thermal floor compares at +0.08 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.20 to 0.22) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.20 lowers cooling load.

Data provenance links certification 2023-11-09 and FENSTAR license 2018-07-12 inside EPA Version 7.0 tables. Heat transfer computes to 162.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8 certified glazing combinations for #4200 Single Slider (NFRC WAL) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 4 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 8 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Duke Vinyl Windows** — Marquis Picture Window](https://ela-ecolandscapingassn.org/windows/models/duke-vinyl-windows-marquis-picture-window-413188/) | Vinyl | 0.27 | 0.17 | 12 |
| [**Duke Vinyl Windows** — Marquis Casement](https://ela-ecolandscapingassn.org/windows/models/duke-vinyl-windows-marquis-casement-413189/) | Vinyl | 0.27 | 0.14 | 15 |
| [**Vytex Corporation** — Georgetown Double Hung](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-georgetown-double-hung-414291/) | Vinyl | 0.27 | 0.19 | 16 |
| [**Vytex Corporation** — Georgetown Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/vytex-corporation-georgetown-horizontal-slider-414289/) | Vinyl | 0.27 | 0.18 | 16 |
| [**Silver Line Building Products** — 2130 IMPACT Fixed Window](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-2130-impact-fixed-window-414092/) | Vinyl | 0.27 | 0.19 | 20 |

## What other certified series does Walsh Building Products produce?

Compare other active Walsh Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.17

### [6300 Picture Window](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6300-picture-window-414308/)

U-Factor 0.17–0.27 · 74 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6300-picture-window-414308/)

Awning (Projected)Min U 0.19

### [6500 Awning Window](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6500-awning-window-414309/)

U-Factor 0.19–0.28 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6500-awning-window-414309/)

Picture WindowMin U 0.19

### [6700 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6700-casement-picture-window-414311/)

U-Factor 0.19–0.27 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6700-casement-picture-window-414311/)

Double HungMin U 0.20

### [6000 Double Hung](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6000-double-hung-414306/)

U-Factor 0.20–0.31 · 119 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6000-double-hung-414306/)

Double SliderMin U 0.20

### [6100 Double Slider](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6100-double-slider-414307/)

U-Factor 0.20–0.31 · 59 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6100-double-slider-414307/)

Casement WindowsMin U 0.20

### [6600 Casement](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6600-casement-414310/)

U-Factor 0.20–0.28 · 24 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/walsh-building-products-6600-casement-414310/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Walsh Building Products #4200 Single Slider appear below.

### What U-Factor and SHGC range does Walsh Building Products #4200 Single Slider achieve?

Built with Vinyl framing in Horizontal Slider (HSOX) style, Walsh Building Products #4200 Single Slider offers 8 Version 7.0 configurations from U 0.27 up to 0.30, posting +0.07 against the Window median of 0.20 with 0 Most Efficient picks.

### Does Walsh Building Products #4200 Single Slider qualify for the ENERGY STAR Northern Zone?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.27). Focus on South-Central, Southern glazing applications where SHGC 0.20-0.22 manages cooling loads.

### What conductive BTU/hr difference separates #4200 Single Slider from the 0.22 Northern rule?

Using NFRC WAL U-Factor 0.27, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 162.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+30.0 BTU/hr margin).

### Which situations make #4200 Single Slider the wrong window or door choice?

Skip #4200 Single Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on #4200 Single Slider options exceeding U 0.22.

### Does #4200 Single Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 8 Southern-certified options inside Walsh Building Products #4200 Single Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.22 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Does #4200 Single Slider carry EPA Most Efficient certification across its lineup?

All 8 #4200 Single Slider listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

### Do 2026 #4200 Single Slider installations qualify for IRS Section 25C tax credits?

Any #4200 Single Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### Where are NFRC and IGCC identification marks located on #4200 Single Slider?

Confirm both the paper NFRC label and permanent corner glass etch match line WAL-K-30 and NFRC ID WAL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Walsh Building Products #4200 Single Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)