title: "Weather Shield Mfg. 4702 Sliding Patio Door Specs (U 0.27)"
url: https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-4702-sliding-patio-door-414379/
description: "Weather Shield Mfg. 4702 Sliding Patio Door (WEA-N-344, Sliding Patio Door, Aluminum): U-Factor 0.27-0.28, SHGC 0.17-0.19, 8 options across 2 ENERGY STAR."
---

Door · Aluminum Frame NFRC WEA · Product Line WEA-N-344

# Weather Shield Mfg., Inc. — 4702 Sliding Patio Door · Sliding Patio Door

Positioning #249/268 in certified Door, Weather Shield Mfg., Inc. 4702 Sliding Patio Door pairs Aluminum frame construction with 8 glazing options rated between 0.17 and 0.19 SHGC across South-Central, Southern. Across 30 certified Weather Shield Mfg., Inc. product families, its thermal resistance spans 0.27 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.27

- **SHGC Range** : 0.17-0.19

- **Certified Options** : 8

- **Category Standing** : #249 of 268

## How does Weather Shield Mfg., Inc. 4702 Sliding Patio Door compare thermally against Door peers?

Weather Shield Mfg., Inc. 4702 Sliding Patio Door achieves a 0.27 thermal floor across Door lines, placing #249 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), 4702 Sliding Patio Door is 0.06 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Aluminum frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.27-0.28.

Evaluating climate compliance across South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 162.0 BTU/hr (+22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-07-31.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 8 certified glazing combinations for 4702 Sliding Patio Door (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 8 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 8 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Foshan Xiaoluban Doors and Windows Co., Ltd.** — BiFold Door](https://ela-ecolandscapingassn.org/windows/models/foshan-xiaoluban-doors-and-windows-co-ltd-bifold-door-413251/) | Aluminum | 0.27 | 0.17 | 1 |
| [**ESWindows LLC** — ES-LG525 Entrance Door](https://ela-ecolandscapingassn.org/windows/models/eswindows-llc-es-lg525-entrance-door-413217/) | Aluminum | 0.27 | 0.09 | 54 |
| [**Neuma Door** — Folding Door](https://ela-ecolandscapingassn.org/windows/models/nan-ya-plastics-corporation-neuma-door-folding-door-413822/) | Composite | 0.27 | 0.09 | 15 |
| [**Andersen Corporation** — 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-hinged-patio-door-inswing-low-thresh/) | Wood | 0.27 | 0.12 | 23 |
| [**Windsor Windows and Doors** — Pinnacle Clad Narrow Stile Outswing Patio Door](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-narrow-stile-outswing-patio/) | Wood | 0.27 | 0.13 | 35 |

## What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [630 Wood Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

U-Factor 0.14–0.32 · 5,555 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

Picture WindowMin U 0.16

### [8306 / 1309 / 1310 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

U-Factor 0.16–0.32 · 1,033 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

Picture WindowMin U 0.16

### [8307/1311 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

U-Factor 0.16–0.32 · 906 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

Picture WindowMin U 0.17

### [8211/8216/1209/1210 Premium Casement Picture](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

U-Factor 0.17–0.32 · 885 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

Picture WindowMin U 0.17

### [8312 Flush Frame Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

U-Factor 0.17–0.32 · 4,388 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

Picture WindowMin U 0.18

### [6121 Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

U-Factor 0.18–0.32 · 2,658 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 4702 Sliding Patio Door appear below.

### Where does Weather Shield Mfg., Inc. 4702 Sliding Patio Door stand thermally among ENERGY STAR Door lines?

Built with Aluminum framing in Sliding Glass Door (DDSG) style, Weather Shield Mfg., Inc. 4702 Sliding Patio Door offers 8 Version 7.0 configurations from U 0.27 up to 0.28, posting +0.06 against the Door median of 0.21 with 0 Most Efficient picks.

### Does Weather Shield Mfg., Inc. 4702 Sliding Patio Door qualify for the ENERGY STAR Northern Zone?

No—with 0 Northern packages and a 0.27 thermal floor, Weather Shield Mfg., Inc. 4702 Sliding Patio Door targets warmer South-Central, Southern climates instead of cold Northern installations.

### How does a 3x5 ft 4702 Sliding Patio Door window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 4702 Sliding Patio Door at U 0.27 conducts 162.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### What are the practical limitations of specifying 4702 Sliding Patio Door?

Do not specify 4702 Sliding Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 4702 Sliding Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

### What Southern ENERGY STAR v7.0 options exist in 4702 Sliding Patio Door?

Warm-climate homeowners have 8 Southern-approved options within 4702 Sliding Patio Door spanning SHGC down to 0.17. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### What glazing share inside 4702 Sliding Patio Door qualifies as Most Efficient?

Zero glazing builds inside 4702 Sliding Patio Door's 8 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### Can homeowners claim Form 5695 credits on Weather Shield Mfg., Inc. 4702 Sliding Patio Door in 2026?

Any 4702 Sliding Patio Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### Where are NFRC and IGCC identification marks located on 4702 Sliding Patio Door?

Match the NFRC thermal sticker for code WEA and line WEA-N-344 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 4702 Sliding Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)