title: "Weather Shield Mfg. 630 Wood Direct Set Specs (U 0.14)"
url: https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/
description: "Weather Shield Mfg. 630 Wood Direct Set (WEA-N-229, Picture Window, Wood): U-Factor 0.14-0.32, SHGC 0.13-0.56, 5555 options across 4 ENERGY STAR zones."
---

Window · Wood Frame NFRC WEA · Product Line WEA-N-229 ENERGY STAR Most Efficient Eligible

# Weather Shield Mfg., Inc. — 630 Wood Direct Set · Picture Window

Across 30 Weather Shield Mfg., Inc. certified families, 630 Wood Direct Set supplies 5,555 Picture Window configurations starting at 0.14 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.56 SHGC. Its thermal floor ranks #72 of 1,352 category entries—0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.14

- **SHGC Range** : 0.13-0.56

- **Certified Options** : 5,555

- **Category Standing** : #72 of 1,352

## How does Weather Shield Mfg., Inc. 630 Wood Direct Set compare thermally against Window peers?

Weather Shield Mfg., Inc. 630 Wood Direct Set achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 630 Wood Direct Set spans 5,555 NFRC test records (WEA), ranking #72 of 1,352 Window families (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%). Its 0.14 thermal floor compares at -0.07 against the Wood median (0.21).

Regional qualification covers Northern, North-Central, South-Central, Southern. 2,220 configurations meet ENERGY STAR Most Efficient criteria while 2,148 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2026-02-12 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 84.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 5,555 certified glazing combinations for 630 Wood Direct Set (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 2,148 packages (1,116 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 3,561 packages (1,894 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 3,140 packages (1,204 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 3,958 packages (1,473 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**JELD-WEN, inc.** — Siteline Clad Wood (W-5500) Fixed Direct Set Geo](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-siteline-clad-wood-w-5500-fixed-direct-set-geo-413384/) | Wood | 0.14 | 0.13 | 4,582 |
| [**Andersen Corporation** — Complementary Wood Specialty Windows - Direct-Set](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-complementary-wood-specialty-windows-direct-set/) | Wood | 0.14 | 0.14 | 7,588 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Push-Out Casement Picture](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-push-out-casement-picture-4134/) | Wood | 0.14 | 0.10 | 2,719 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Casement_Sliding Door Transom Sash Set](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-casement-sliding-door-transom/) | Wood | 0.14 | 0.09 | 1,868 |
| [**Sierra Pacific Windows** — Clad Aspen Fixed](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-clad-aspen-fixed-414079/) | Wood | 0.14 | 0.10 | 1,585 |

## What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.16

### [8306 / 1309 / 1310 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

U-Factor 0.16–0.32 · 1,033 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

Picture WindowMin U 0.16

### [8307/1311 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

U-Factor 0.16–0.32 · 906 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

Picture WindowMin U 0.17

### [8211/8216/1209/1210 Premium Casement Picture](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

U-Factor 0.17–0.32 · 885 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

Picture WindowMin U 0.17

### [8312 Flush Frame Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

U-Factor 0.17–0.32 · 4,388 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

Picture WindowMin U 0.18

### [6121 Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

U-Factor 0.18–0.32 · 2,658 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

Awning (Projected)Min U 0.20

### [8211/8216/1209/1210 Awning](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-awning-414358/)

U-Factor 0.20–0.32 · 515 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-awning-414358/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 630 Wood Direct Set appear below.

### How efficient is Weather Shield Mfg., Inc. 630 Wood Direct Set compared with peer Window models?

Weather Shield Mfg., Inc. 630 Wood Direct Set spans 5,555 certified configurations with U-Factors between 0.14 and 0.32 and SHGC values from 0.13 to 0.56. Ranked #72 of 1,352 Window families, it carries 2,220 Most Efficient options.

### Which glazing options in Weather Shield Mfg., Inc. 630 Wood Direct Set meet Northern climate limits?

Cold-climate buyers get 2,148 compliant Northern packages inside 630 Wood Direct Set, reaching down to U 0.14. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

### What conductive BTU/hr difference separates 630 Wood Direct Set from the 0.22 Northern rule?

Using NFRC WEA U-Factor 0.14, a 15 sq ft Fixed Window (FIXD) assembly conducts 84.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-48.0 BTU/hr margin).

### What are the practical limitations of specifying 630 Wood Direct Set?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 630 Wood Direct Set options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### Can you install Weather Shield Mfg., Inc. 630 Wood Direct Set in Southern or South-Central zones?

Warm-climate homeowners have 3,958 Southern-approved options within 630 Wood Direct Set spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Does 630 Wood Direct Set carry EPA Most Efficient certification across its lineup?

No. Exactly 2,220 of 5,555 configurations (40.0%) earn ENERGY STAR Most Efficient status in 630 Wood Direct Set; the remaining standard v7.0 options pass base zone limits only.

### Do 2026 630 Wood Direct Set installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 630 Wood Direct Set installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How do you cross-check NFRC WEA and product line WEA-N-229 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WEA and product line WEA-N-229, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 630 Wood Direct Set come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)