title: "Weather Shield Mfg. 8211/8216/1209/1210 Awning Specs"
url: https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-awning-414358/
description: "Weather Shield Mfg. 8211/8216/1209/1210 Awning (WEA-N-287, Awning (Projected), Wood): U-Factor 0.20-0.32, SHGC 0.11-0.40, 515 options across 4 ENERGY STAR."
---

Window · Wood Frame NFRC WEA · Product Line WEA-N-287 ENERGY STAR Most Efficient Eligible

# Weather Shield Mfg., Inc. — 8211/8216/1209/1210 Awning · Awning (Projected)

Across 30 Weather Shield Mfg., Inc. certified families, 8211/8216/1209/1210 Awning supplies 515 Awning, Projected configurations starting at 0.20 U-Factor and 0.11 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.40 SHGC. Its thermal floor ranks #671 of 1,352 category entries—matches the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.20

- **SHGC Range** : 0.11-0.40

- **Certified Options** : 515

- **Category Standing** : #671 of 1,352

## How does Weather Shield Mfg., Inc. 8211/8216/1209/1210 Awning compare thermally against Window peers?

Weather Shield Mfg., Inc. 8211/8216/1209/1210 Awning achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 8211/8216/1209/1210 Awning is matches the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.20-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 51 configurations meet ENERGY STAR Most Efficient criteria while 25 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2024-02-27. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.20 conducts 120.0 BTU/hr (-12.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 515 certified glazing combinations for 8211/8216/1209/1210 Awning (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 25 packages (0 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 201 packages (10 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 258 packages (10 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 474 packages (51 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Inswing Casement](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-inswing-casement-413473/) | Wood | 0.20 | 0.08 | 712 |
| [**Lincoln Wood Products, Inc.** — Clad Casement - Crank-Out & Push-Out](https://ela-ecolandscapingassn.org/windows/models/lincoln-wood-products-inc-clad-casement-crank-out-push-out-414181/) | Wood | 0.20 | 0.15 | 217 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Traditional Double Hung](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-traditional-double-hung-413/) | Wood | 0.20 | 0.10 | 196 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra Casement](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-casement-413457/) | Wood | 0.20 | 0.09 | 893 |
| [**Andersen Corporation** — 400 Series Awning Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-awning-window-412912/) | Wood | 0.20 | 0.14 | 1,015 |

## What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [630 Wood Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

U-Factor 0.14–0.32 · 5,555 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

Picture WindowMin U 0.16

### [8306 / 1309 / 1310 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

U-Factor 0.16–0.32 · 1,033 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

Picture WindowMin U 0.16

### [8307/1311 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

U-Factor 0.16–0.32 · 906 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

Picture WindowMin U 0.17

### [8211/8216/1209/1210 Premium Casement Picture](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

U-Factor 0.17–0.32 · 885 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

Picture WindowMin U 0.17

### [8312 Flush Frame Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

U-Factor 0.17–0.32 · 4,388 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

Picture WindowMin U 0.18

### [6121 Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

U-Factor 0.18–0.32 · 2,658 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 8211/8216/1209/1210 Awning appear below.

### How efficient is Weather Shield Mfg., Inc. 8211/8216/1209/1210 Awning compared with peer Window models?

Across 515 tested NFRC glazing configurations, Weather Shield Mfg., Inc. 8211/8216/1209/1210 Awning with Wood framing and Projected Awning (PRAW) style reaches a 0.20 minimum U-Factor and 0.11-0.40 SHGC band. It places #671 among 1,352 Window series—more insulating than 45.2%.

### Which glazing options in Weather Shield Mfg., Inc. 8211/8216/1209/1210 Awning meet Northern climate limits?

Yes, 25 packages satisfy Northern ENERGY STAR Version 7.0 rules in 8211/8216/1209/1210 Awning. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### What conductive BTU/hr difference separates 8211/8216/1209/1210 Awning from the 0.22 Northern rule?

Using NFRC WEA U-Factor 0.20, a 15 sq ft Projected Awning (PRAW) assembly conducts 120.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-12.0 BTU/hr margin).

### What are the practical limitations of specifying 8211/8216/1209/1210 Awning?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8211/8216/1209/1210 Awning options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### Is 8211/8216/1209/1210 Awning suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 474 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Weather Shield Mfg., Inc. 8211/8216/1209/1210 Awning, while total line SHGC reaches 0.40 in colder packages.

### Are all 515 8211/8216/1209/1210 Awning configurations ENERGY STAR Most Efficient?

Within 8211/8216/1209/1210 Awning, 9.9% (51 of 515) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 8211/8216/1209/1210 Awning?

Any 8211/8216/1209/1210 Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### Where are NFRC and IGCC identification marks located on 8211/8216/1209/1210 Awning?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WEA and product line WEA-N-287, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 8211/8216/1209/1210 Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)