---
title: "Weather Shield Mfg. 8217 Push-Out Awning Specs (U 0.25)"
url: https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8217-push-out-awning-414373/
description: "Weather Shield Mfg. 8217 Push-Out Awning (WEA-N-324, Awning (Projected), Wood): U-Factor 0.25-0.32, SHGC 0.11-0.26, 302 options across 3 ENERGY STAR zones."
---

Window · Wood Frame NFRC WEA · Product Line WEA-N-324

# Weather Shield Mfg., Inc. — 8217 Push-Out Awning · Awning (Projected)

EPA ENERGY STAR Version 7.0 certifies 302 variants inside Weather Shield Mfg., Inc. 8217 Push-Out Awning, combining Wood frame construction with U-Factors spanning 0.25 to 0.32 and SHGC 0.11 to 0.26. Qualifying for North-Central, South-Central, Southern, this Awning, Projected family places #1,174 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median among Wood peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.11-0.26

- **Certified Options** : 302

- **Category Standing** : #1,174 of 1,352

## How does Weather Shield Mfg., Inc. 8217 Push-Out Awning compare thermally against Window peers?

Weather Shield Mfg., Inc. 8217 Push-Out Awning achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), 8217 Push-Out Awning reaches 0.25 on its lowest-conductivity package — #319 of 408 in Wood, tied with 32 others at 0.25, more insulating than 14.0% of Wood lines (+0.04 vs Wood peers). Pairing NFRC ID WEA across multi-pane fills shifts U-Factor from 0.32 down toward 0.25.

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.11 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 150.0 BTU/hr (+13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-07-09.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 302 certified glazing combinations for 8217 Push-Out Awning (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 20 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 91 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 298 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 400 Series Woodwright® Double-Hung Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-woodwright-double-hung-full-frame-wi/) | Wood | 0.25 | 0.15 | 280 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Ultra/VistaLuxe Exterior Folding Window](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-ultra-vistaluxe-exterior-folding-win/) | Wood | 0.25 | 0.08 | 271 |
| [**Windsor Windows and Doors** — Pinnacle Clad Awning 3.25" Frame](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-awning-3-25-frame-414449/) | Wood | 0.25 | 0.15 | 354 |
| [**Windsor Windows and Doors** — Pinnacle Clad Awning](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-awning-414392/) | Wood | 0.25 | 0.15 | 362 |
| [**Windsor Windows and Doors** — Pinnacle Clad Casement 3.25" Frame](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-casement-3-25-frame-414447/) | Wood | 0.25 | 0.15 | 371 |

## What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [630 Wood Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

U-Factor 0.14–0.32 · 5,555 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

Picture WindowMin U 0.16

### [8306 / 1309 / 1310 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

U-Factor 0.16–0.32 · 1,033 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

Picture WindowMin U 0.16

### [8307/1311 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

U-Factor 0.16–0.32 · 906 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

Picture WindowMin U 0.17

### [8211/8216/1209/1210 Premium Casement Picture](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

U-Factor 0.17–0.32 · 885 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

Picture WindowMin U 0.17

### [8312 Flush Frame Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

U-Factor 0.17–0.32 · 4,388 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

Picture WindowMin U 0.18

### [6121 Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

U-Factor 0.18–0.32 · 2,658 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 8217 Push-Out Awning appear below.

### Where does Weather Shield Mfg., Inc. 8217 Push-Out Awning stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 302 configurations for Weather Shield Mfg., Inc. 8217 Push-Out Awning covering North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Does Weather Shield Mfg., Inc. 8217 Push-Out Awning qualify for the ENERGY STAR Northern Zone?

Weather Shield Mfg., Inc. 8217 Push-Out Awning holds zero Northern Zone qualifications (min U 0.25). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### What conductive BTU/hr difference separates 8217 Push-Out Awning from the 0.22 Northern rule?

Using NFRC WEA U-Factor 0.25, a 15 sq ft Projected Awning (PRAW) assembly conducts 150.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+18.0 BTU/hr margin).

### When should a buyer skip Weather Shield Mfg., Inc. 8217 Push-Out Awning and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 8217 Push-Out Awning options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Weather Shield Mfg., Inc. 8217 Push-Out Awning in Southern or South-Central zones?

Warm-climate homeowners have 298 Southern-approved options within 8217 Push-Out Awning spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Which package tier in 8217 Push-Out Awning holds Most Efficient recognition?

Zero glazing builds inside 8217 Push-Out Awning's 302 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

### Do 2026 8217 Push-Out Awning installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

### Where are NFRC and IGCC identification marks located on 8217 Push-Out Awning?

Confirm both the paper NFRC label and permanent corner glass etch match line WEA-N-324 and NFRC ID WEA before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 8217 Push-Out Awning come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
