---
title: "Weather Shield Mfg. 8312 Flush Frame Direct Set Specs"
url: https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/
description: "Weather Shield Mfg. 8312 Flush Frame Direct Set (WEA-N-310, Picture Window, Wood): U-Factor 0.17-0.32, SHGC 0.13-0.54, 4388 options across 4 ENERGY STAR."
---

Window · Wood Frame NFRC WEA · Product Line WEA-N-310 ENERGY STAR Most Efficient Eligible

# Weather Shield Mfg., Inc. — 8312 Flush Frame Direct Set · Picture Window

Weather Shield Mfg., Inc. engineered the 8312 Flush Frame Direct Set Picture Window line for Northern, North-Central, South-Central, Southern, certifying 4,388 glass-spacer combinations from 0.17 to 0.32 U-Factor and 0.13 to 0.54 SHGC. Relative to other Wood models tracked under NFRC WEA, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.17

- **SHGC Range** : 0.13-0.54

- **Certified Options** : 4,388

- **Category Standing** : #362 of 1,352

## How does Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set compare thermally against Window peers?

Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Wood cohort (0.21 median U-Factor), 8312 Flush Frame Direct Set reaches 0.17 on its lowest-conductivity package — #88 of 408 in Wood, tied with 34 others at 0.17, more insulating than 70.1% of Wood lines, top 29.9% (-0.04 vs Wood peers). Pairing NFRC ID WEA across multi-pane fills shifts U-Factor from 0.32 down toward 0.17.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 1,346 configurations meet ENERGY STAR Most Efficient criteria while 1,342 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2026-02-12. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,388 certified glazing combinations for 8312 Flush Frame Direct Set (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 1,342 packages (441 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 2,386 packages (985 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 2,194 packages (722 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 3,463 packages (1,075 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 400 Series Specialty Window - Casement Half Circle](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-window-casement-half-circl/) | Wood | 0.17 | 0.15 | 5,280 |
| [**Andersen Corporation** — 400 Series Specialty Window - Double Hung Half Circle](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-window-double-hung-half-ci/) | Wood | 0.17 | 0.15 | 2,938 |
| [**Andersen Corporation** — 400 Series Tilt-Wash Double-Hung Full-Frame Window](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-tilt-wash-double-hung-full-frame-win/) | Wood | 0.17 | 0.13 | 2,574 |
| [**Andersen Corporation** — 400 Series Specialty Windows - Circle/Oval](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-windows-circle-oval-412982/) | Wood | 0.17 | 0.15 | 2,472 |
| [**Andersen Corporation** — 400 Series Specialty Window - Elliptical](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-400-series-specialty-window-elliptical-412916/) | Wood | 0.17 | 0.14 | 2,428 |

## What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [630 Wood Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

U-Factor 0.14–0.32 · 5,555 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

Picture WindowMin U 0.16

### [8306 / 1309 / 1310 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

U-Factor 0.16–0.32 · 1,033 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

Picture WindowMin U 0.16

### [8307/1311 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

U-Factor 0.16–0.32 · 906 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

Picture WindowMin U 0.17

### [8211/8216/1209/1210 Premium Casement Picture](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

U-Factor 0.17–0.32 · 885 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

Picture WindowMin U 0.18

### [6121 Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

U-Factor 0.18–0.32 · 2,658 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

Awning (Projected)Min U 0.20

### [8211/8216/1209/1210 Awning](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-awning-414358/)

U-Factor 0.20–0.32 · 515 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-awning-414358/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set appear below.

### How efficient is Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set compared with peer Window models?

EPA ENERGY STAR v7.0 records 4,388 configurations for Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.20 Window median. Only 1,346 options earn Most Efficient status.

### Which glazing options in Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set meet Northern climate limits?

Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set supplies 1,342 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### How does a 3x5 ft 8312 Flush Frame Direct Set window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on 8312 Flush Frame Direct Set's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

### Who should NOT choose Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 8312 Flush Frame Direct Set options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Can you install Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set in Southern or South-Central zones?

Yes, 8312 Flush Frame Direct Set holds 3,463 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

### Does 8312 Flush Frame Direct Set carry EPA Most Efficient certification across its lineup?

No. Exactly 1,346 of 4,388 configurations (30.7%) earn ENERGY STAR Most Efficient status in 8312 Flush Frame Direct Set; the remaining standard v7.0 options pass base zone limits only.

### What federal compliance checks govern 2026 8312 Flush Frame Direct Set window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 8312 Flush Frame Direct Set retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do building inspectors verify 8312 Flush Frame Direct Set glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.17-0.32, SHGC 0.13-0.54) against permit drawings for line WEA-N-310. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 8312 Flush Frame Direct Set come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
