title: "Weather Shield Mfg. 8511/1507 Inswing Door Specs (U 0.26)"
url: https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8511-1507-inswing-door-414351/
description: "Weather Shield Mfg. 8511/1507 Inswing Door (WEA-N-248, Swinging Entry Door (Single), Wood): U-Factor 0.26-0.28, SHGC 0.11-0.15, 50 options across 4 ENERGY."
---

Door · Wood Frame NFRC WEA · Product Line WEA-N-248

# Weather Shield Mfg., Inc. — 8511/1507 Inswing Door · Swinging Entry Door (Single)

Positioning #233/268 in certified Door, Weather Shield Mfg., Inc. 8511/1507 Inswing Door pairs Wood frame construction with 50 glazing options rated between 0.11 and 0.15 SHGC across Northern, North-Central, South-Central, Southern. Across 30 certified Weather Shield Mfg., Inc. product families, its thermal resistance spans 0.26 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.26

- **SHGC Range** : 0.11-0.15

- **Certified Options** : 50

- **Category Standing** : #233 of 268

## How does Weather Shield Mfg., Inc. 8511/1507 Inswing Door compare thermally against Door peers?

Weather Shield Mfg., Inc. 8511/1507 Inswing Door achieves a 0.26 thermal floor across Door lines, placing #233 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), 8511/1507 Inswing Door is 0.05 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.26-0.28.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.26 floor sits above the 0.22 prescriptive Northern ceiling, 2 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-03-10 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 156.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 50 certified glazing combinations for 8511/1507 Inswing Door (NFRC WEA) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 2 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 2 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 50 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 50 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.26 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Pinnacle Clad Inswing Narrow Stile Patio Door](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-inswing-narrow-stile-patio-d/) | Wood | 0.26 | 0.13 | 54 |
| [**Windsor Windows and Doors** — Pinnacle Clad Inswing Narrow Stile Fixed Patio Door (Stationary Panel)](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-inswing-narrow-stile-fixed-p/) | Wood | 0.26 | 0.13 | 60 |
| [**Windsor Windows and Doors** — Pinnacle Primed Inswing Door](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-primed-inswing-door-414417/) | Wood | 0.26 | 0.12 | 38 |
| [**Pella Corporation** — Reserve Multi-Slide](https://ela-ecolandscapingassn.org/windows/models/pella-corporation-reserve-multi-slide-413914/) | Wood | 0.26 | 0.14 | 69 |
| [**Windsor Windows and Doors** — Pinnacle Prime French Sliding Patio Door](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-prime-french-sliding-patio-door-4/) | Wood | 0.26 | 0.12 | 71 |

## What other certified series does Weather Shield Mfg., Inc. produce?

Compare other active Weather Shield Mfg., Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [630 Wood Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

U-Factor 0.14–0.32 · 5,555 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-630-wood-direct-set-414350/)

Picture WindowMin U 0.16

### [8306 / 1309 / 1310 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

U-Factor 0.16–0.32 · 1,033 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8306-1309-1310-direct-set-414354/)

Picture WindowMin U 0.16

### [8307/1311 Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

U-Factor 0.16–0.32 · 906 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8307-1311-direct-set-414362/)

Picture WindowMin U 0.17

### [8211/8216/1209/1210 Premium Casement Picture](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

U-Factor 0.17–0.32 · 885 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8211-8216-1209-1210-premium-casement-picture/)

Picture WindowMin U 0.17

### [8312 Flush Frame Direct Set](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

U-Factor 0.17–0.32 · 4,388 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8312-flush-frame-direct-set-414367/)

Picture WindowMin U 0.18

### [6121 Double Hung Transom](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

U-Factor 0.18–0.32 · 2,658 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-6121-double-hung-transom-414376/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Weather Shield Mfg., Inc. 8511/1507 Inswing Door appear below.

### How well does 8511/1507 Inswing Door by Weather Shield Mfg., Inc. insulate relative to Door benchmarks?

Testing puts Weather Shield Mfg., Inc. 8511/1507 Inswing Door at rank #233 of 268 Door entries with U 0.26 to 0.28 across 50 configurations. Solar heat gain ranges between 0.11 and 0.15 across Northern, North-Central, South-Central, Southern.

### Does Weather Shield Mfg., Inc. 8511/1507 Inswing Door qualify for the ENERGY STAR Northern Zone?

Northern qualification on 8511/1507 Inswing Door relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.26. Exactly 2 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

### How do you calculate winter heat conduction for Weather Shield Mfg., Inc. 8511/1507 Inswing Door?

Using NFRC WEA U-Factor 0.26, a 15 sq ft Entry Door Single-Lite (EDSL) assembly conducts 156.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+24.0 BTU/hr margin).

### Which situations make 8511/1507 Inswing Door the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8511/1507 Inswing Door options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

### Can you install Weather Shield Mfg., Inc. 8511/1507 Inswing Door in Southern or South-Central zones?

Warm-climate homeowners have 50 Southern-approved options within 8511/1507 Inswing Door spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Are all 50 8511/1507 Inswing Door configurations ENERGY STAR Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 50 8511/1507 Inswing Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### How do the 25C sunset and pre-1978 Lead RRP rules affect 8511/1507 Inswing Door?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 8511/1507 Inswing Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### Where are NFRC and IGCC identification marks located on 8511/1507 Inswing Door?

Inspectors match the temporary NFRC sticker (U 0.26-0.28, SHGC 0.11-0.15) against permit drawings for line WEA-N-248. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Weather Shield Mfg., Inc. 8511/1507 Inswing Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)