---
title: "Westlake Royal Windows 250 Horizontal Slider Specs"
url: https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-250-horizontal-slider-414469/
description: "Westlake Royal Windows 250 Horizontal Slider (WLR-A-6, Single Slider, Vinyl): U-Factor 0.25-0.32, SHGC 0.17-0.23, 376 options across 3 ENERGY STAR zones."
---

Window · Vinyl Frame NFRC WLR · Product Line WLR-A-6

# Westlake Royal Windows LLC — 250 Horizontal Slider · Single Slider

With a minimum U-Factor of 0.25—+0.05 compared against the 0.20 Window median—Westlake Royal Windows LLC 250 Horizontal Slider spans 376 tested options across North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code WLR, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.17 and 0.23.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.17-0.23

- **Certified Options** : 376

- **Category Standing** : #1,174 of 1,352

## How does Westlake Royal Windows LLC 250 Horizontal Slider compare thermally against Window peers?

Westlake Royal Windows LLC 250 Horizontal Slider achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 250 Horizontal Slider is 0.05 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.25-0.32.

Mapping NFRC SHGC values (0.17 to 0.23) against ENERGY STAR Version 7.0 targets approves North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.25 U-Factor yields 150.0 BTU/hr transfer (+18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-05-31 licensing and 2024-06-20 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 376 certified glazing combinations for 250 Horizontal Slider (NFRC WLR) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 98 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 215 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 376 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Windsor Windows and Doors** — Next Dimension Classic Single Hung](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-classic-single-hung-414435/) | Vinyl | 0.25 | 0.12 | 388 |
| [**JELD-WEN, inc.** — Premium Atlantic Vinyl Single Hung](https://ela-ecolandscapingassn.org/windows/models/jeld-wen-inc-premium-atlantic-vinyl-single-hung-413337/) | Vinyl | 0.25 | 0.13 | 408 |
| [**Krestmark Industries L. P.** — 200/220/275 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/krestmark-industries-l-p-200-220-275-horizontal-slider-413501/) | Vinyl | 0.25 | 0.16 | 310 |
| [**Silver Line Building Products** — 1200 Double Hung](https://ela-ecolandscapingassn.org/windows/models/silver-line-building-products-1200-double-hung-414086/) | Vinyl | 0.25 | 0.18 | 283 |
| [**Sierra Pacific Windows** — Vinyl Builders Single Slider](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-builders-single-slider-414076/) | Vinyl | 0.25 | 0.12 | 278 |

## What other certified series does Westlake Royal Windows LLC produce?

Compare other active Westlake Royal Windows LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.21

### [250 Fixed](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-250-fixed-414467/)

U-Factor 0.21–0.32 · 503 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-250-fixed-414467/)

Picture WindowMin U 0.21

### [255 Fixed (CHS)](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-255-fixed-chs-414470/)

U-Factor 0.21–0.32 · 1,047 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-255-fixed-chs-414470/)

Picture WindowMin U 0.22

### [700/7000 Picture Window](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-700-7000-picture-window-414464/)

U-Factor 0.22–0.32 · 1,492 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-700-7000-picture-window-414464/)

Single HungMin U 0.24

### [250 Single Hung](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-250-single-hung-414468/)

U-Factor 0.24–0.32 · 376 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-250-single-hung-414468/)

Single HungMin U 0.24

### [700 Single Hung](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-700-single-hung-414465/)

U-Factor 0.24–0.32 · 405 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-700-single-hung-414465/)

Single SliderMin U 0.25

### [700 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-700-horizontal-slider-414466/)

U-Factor 0.25–0.32 · 275 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-700-horizontal-slider-414466/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Westlake Royal Windows LLC 250 Horizontal Slider appear below.

### How efficient is Westlake Royal Windows LLC 250 Horizontal Slider compared with peer Window models?

EPA ENERGY STAR v7.0 records 376 configurations for Westlake Royal Windows LLC 250 Horizontal Slider covering North-Central, South-Central, Southern, dropping down to U 0.25 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

### Which glazing options in Westlake Royal Windows LLC 250 Horizontal Slider meet Northern climate limits?

Westlake Royal Windows LLC 250 Horizontal Slider holds zero Northern Zone qualifications (min U 0.25). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

### How do you calculate winter heat conduction for Westlake Royal Windows LLC 250 Horizontal Slider?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 250 Horizontal Slider at U 0.25 conducts 150.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

### Which situations make 250 Horizontal Slider the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 250 Horizontal Slider options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### Can you install Westlake Royal Windows LLC 250 Horizontal Slider in Southern or South-Central zones?

Yes, 250 Horizontal Slider holds 376 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.17 SHGC in cooling climates.

### Which package tier in 250 Horizontal Slider holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 376 250 Horizontal Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What 2026 federal tax credit and Lead RRP rules apply to 250 Horizontal Slider?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 250 Horizontal Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

### How do you cross-check NFRC WLR and product line WLR-A-6 on delivery?

Verify NFRC ID WLR and series WLR-A-6 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Westlake Royal Windows LLC 250 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
