---
title: "Wincore Window Company Plastpro Fiberglass Sidelite Specs"
url: https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-plastpro-fiberglass-sidelite-414328/
description: "Wincore Window Company Plastpro Fiberglass Sidelite (WCW-M-18, Sidelite, Steel / Vinyl / Wood): U-Factor 0.13-0.28, SHGC 0.00-0.33, 7791 options across 4."
---

Window · Steel / Vinyl / Wood Frame NFRC WCW · Product Line WCW-M-18

# Wincore Window Company, LLC — Plastpro Fiberglass Sidelite · Sidelite

Across 23 Wincore Window Company, LLC certified families, Plastpro Fiberglass Sidelite supplies 7,791 Sidelite configurations starting at 0.13 U-Factor and 0.00 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.33 SHGC. Its thermal floor ranks #36 of 1,352 category entries—0.07 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.13

- **SHGC Range** : 0.00-0.33

- **Certified Options** : 7,791

- **Category Standing** : #36 of 1,352

## How does Wincore Window Company, LLC Plastpro Fiberglass Sidelite compare thermally against Window peers?

Wincore Window Company, LLC Plastpro Fiberglass Sidelite achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Wincore Window Company, LLC Plastpro Fiberglass Sidelite at rank #36 of 1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.00-0.33 band.

Climate coverage for Wincore Window Company, LLC Plastpro Fiberglass Sidelite spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 7,361 combinations qualify in the Northern Zone alongside 7,629 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Data provenance links certification 2024-12-13 and FENSTAR license 2018-08-23 inside EPA Version 7.0 tables. Heat transfer computes to 78.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,791 certified glazing combinations for Plastpro Fiberglass Sidelite (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Certified | <= 0.22 | >= 0.17 | 7,361 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 7,361 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 7,629 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 7,629 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Plastpro Inc.** — Plastpro Fiberglass Sidelite](https://ela-ecolandscapingassn.org/windows/models/plastpro-inc-plastpro-fiberglass-sidelite-413825/) | Steel / Vinyl / Wood | 0.13 | 0.00 | 7,082 |
| [**Marvin** — Ultimate Wood Direct Glaze Round Top](https://ela-ecolandscapingassn.org/windows/models/marvin-ultimate-wood-direct-glaze-round-top-413619/) | Wood | 0.13 | 0.12 | 8,590 |
| [**MI Windows and Doors, LLC** — 9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-9660-9770-polyvinyl-chloride-pvc-fixed-sash/) | Vinyl | 0.13 | 0.08 | 6,920 |
| [**Kolbe and Kolbe Millwork Co., Inc** — Heritage Gardenaire Sliding Patio Door Sidelite](https://ela-ecolandscapingassn.org/windows/models/kolbe-and-kolbe-millwork-co-inc-heritage-gardenaire-sliding-patio-do/) | Wood | 0.13 | 0.07 | 4,426 |
| [**EnergyWall Window** — 8605/3205 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/energywall-window-8605-3205-casement-picture-window-413230/) | Vinyl | 0.13 | 0.16 | 3,472 |

## What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.14

### [7700, 8400, 8800 Picture Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-7700-8400-8800-picture-window-414346/)

U-Factor 0.14–0.32 · 28,216 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-7700-8400-8800-picture-window-414346/)

Picture WindowMin U 0.15

### [5400, 7700 Casement Picture Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-7700-casement-picture-window-414336/)

U-Factor 0.15–0.32 · 16,031 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-7700-casement-picture-window-414336/)

Single HungMin U 0.15

### [9400, 9700, 8800, 9800 Single Hung](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-9400-9700-8800-9800-single-hung-414349/)

U-Factor 0.15–0.32 · 189,040 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-9400-9700-8800-9800-single-hung-414349/)

Swinging Entry Door (Single)Min U 0.16

### [Fiberglass Entry Door](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-fiberglass-entry-door-414327/)

U-Factor 0.16–0.28 · 11,717 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-fiberglass-entry-door-414327/)

Casement WindowsMin U 0.17

### [5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Out-Swing Casement Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin/)

U-Factor 0.17–0.32 · 6,278 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin/)

Awning (Projected)Min U 0.17

### [5400, 5400S, 7700, 8400, 8800, 9900 Series Vinyl Awning Window](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin-414335/)

U-Factor 0.17–0.32 · 6,256 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/wincore-window-company-llc-5400-5400s-7700-8400-8800-9900-series-vin-414335/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC Plastpro Fiberglass Sidelite appear below.

### What thermal performance numbers separate Wincore Window Company, LLC Plastpro Fiberglass Sidelite from peers?

Wincore Window Company, LLC Plastpro Fiberglass Sidelite spans 7,791 certified configurations with U-Factors between 0.13 and 0.28 and SHGC values from 0.00 to 0.33. Ranked #36 of 1,352 Window families, it carries 0 Most Efficient options.

### Is Plastpro Fiberglass Sidelite approved for Northern Zone heating climates?

Wincore Window Company, LLC Plastpro Fiberglass Sidelite supplies 7,361 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

### What conductive BTU/hr difference separates Plastpro Fiberglass Sidelite from the 0.22 Northern rule?

At U 0.13, a standard 3x5 ft (15 sq ft) Plastpro Fiberglass Sidelite opening transfers 78.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -54.0 BTU/hr difference.

### When should a buyer skip Wincore Window Company, LLC Plastpro Fiberglass Sidelite and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Plastpro Fiberglass Sidelite options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Is Plastpro Fiberglass Sidelite suitable for sunbelt cooling-dominated homes?

Yes, Plastpro Fiberglass Sidelite holds 7,629 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.00 SHGC in cooling climates.

### What glazing share inside Plastpro Fiberglass Sidelite qualifies as Most Efficient?

No. Zero of the 7,791 configurations in Wincore Window Company, LLC Plastpro Fiberglass Sidelite hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### How do the 25C sunset and pre-1978 Lead RRP rules affect Plastpro Fiberglass Sidelite?

Any Plastpro Fiberglass Sidelite purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### What permanent glass etch marks verify Plastpro Fiberglass Sidelite after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line WCW-M-18 and NFRC ID WCW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC Plastpro Fiberglass Sidelite come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
