title: "Windsor Windows and Doors Next Dimension Picture Specs"
url: https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-picture-414458/
description: "Windsor Windows and Doors Next Dimension Picture (WIN-N-193, Picture Window, Vinyl): U-Factor 0.16-0.32, SHGC 0.12-0.53, 1539 options across 4 ENERGY STAR."
---

Window · Vinyl Frame NFRC WIN · Product Line WIN-N-193 ENERGY STAR Most Efficient Eligible

# Windsor Windows and Doors — Next Dimension Picture · Picture Window

Windsor Windows and Doors Next Dimension Picture is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.16 across 1,539 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.53.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.16

- **SHGC Range** : 0.12-0.53

- **Certified Options** : 1,539

- **Category Standing** : #250 of 1,352

## How does Windsor Windows and Doors Next Dimension Picture compare thermally against Window peers?

Windsor Windows and Doors Next Dimension Picture achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Next Dimension Picture reaches 0.16 on its lowest-conductivity package — #170 of 1,009 in Vinyl, tied with 100 others at 0.16, more insulating than 73.2% of Vinyl lines, top 26.8% (-0.03 vs Vinyl peers). Pairing NFRC ID WIN across multi-pane fills shifts U-Factor from 0.32 down toward 0.16.

Mapping NFRC SHGC values (0.12 to 0.53) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 229 configurations meet ENERGY STAR Most Efficient criteria while 394 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2025-08-21 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,539 certified glazing combinations for Next Dimension Picture (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 394 packages (80 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 433 packages (100 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 771 packages (72 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 1,303 packages (161 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Interstate Building Materials, Inc.** — 440/6800/8800 Double Slider](https://ela-ecolandscapingassn.org/windows/models/interstate-building-materials-inc-440-6800-8800-double-slider-413323/) | Vinyl | 0.16 | 0.18 | 1,522 |
| [**DRUTEX S.A.** — IGLO Energy Fixed Window Plus COMBI Threshold](https://ela-ecolandscapingassn.org/windows/models/drutex-s-a-iglo-energy-fixed-window-plus-combi-threshold-413163/) | Vinyl | 0.16 | 0.15 | 1,443 |
| [**ProVia LLC** — Vinyl Double Hung Window](https://ela-ecolandscapingassn.org/windows/models/provia-llc-vinyl-double-hung-window-413949/) | Vinyl | 0.16 | 0.05 | 1,307 |
| [**Amsco Windows** — VLS STC Serenity Picture Window](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vls-stc-serenity-picture-window-412894/) | Vinyl | 0.16 | 0.12 | 1,272 |
| [**Gerkin Windows and Doors** — 4300 Series Casement](https://ela-ecolandscapingassn.org/windows/models/gerkin-windows-and-doors-4300-series-casement-413263/) | Vinyl | 0.16 | 0.08 | 1,268 |

## What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [Pinnacle Clad Radius Direct Glaze](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/)

U-Factor 0.15–0.32 · 1,266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/)

Picture WindowMin U 0.16

### [Next Dimension Radius](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-radius-414463/)

U-Factor 0.16–0.32 · 1,382 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-radius-414463/)

Picture WindowMin U 0.17

### [Next Dimension Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/)

U-Factor 0.17–0.32 · 1,610 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/)

Picture WindowMin U 0.17

### [Pinnacle Clad Direct Set 3.25" Frame](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/)

U-Factor 0.17–0.32 · 817 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/)

Picture WindowMin U 0.17

### [Pinnacle Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-414388/)

U-Factor 0.17–0.32 · 1,162 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-414388/)

Picture WindowMin U 0.17

### [Pinnacle Select Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-select-casement-picture-414434/)

U-Factor 0.17–0.32 · 1,248 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-select-casement-picture-414434/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Next Dimension Picture appear below.

### What U-Factor and SHGC range does Windsor Windows and Doors Next Dimension Picture achieve?

Windsor Windows and Doors Next Dimension Picture spans 1,539 certified configurations with U-Factors between 0.16 and 0.32 and SHGC values from 0.12 to 0.53. Ranked #250 of 1,352 Window families, it carries 229 Most Efficient options.

### Which glazing options in Windsor Windows and Doors Next Dimension Picture meet Northern climate limits?

Yes, 394 packages satisfy Northern ENERGY STAR Version 7.0 rules in Next Dimension Picture. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

### What BTU/hr heat transfer results from Next Dimension Picture's 0.16 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### Who should NOT choose Windsor Windows and Doors Next Dimension Picture for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Next Dimension Picture options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Does Next Dimension Picture meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 1,303 Southern-approved options within Next Dimension Picture spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

### Which package tier in Next Dimension Picture holds Most Efficient recognition?

No. Exactly 229 of 1,539 configurations (14.9%) earn ENERGY STAR Most Efficient status in Next Dimension Picture; the remaining standard v7.0 options pass base zone limits only.

### Do 2026 Next Dimension Picture installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Windsor Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

### How can homeowners confirm delivered Windsor Windows and Doors Next Dimension Picture units match permits?

Confirm both the paper NFRC label and permanent corner glass etch match line WIN-N-193 and NFRC ID WIN before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Next Dimension Picture come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)