title: "Windsor Windows and Doors Next HSOX [WIN-N-145]"
url: https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-pro-brickmould-slider-41442/
description: "Windsor Windows and Doors Next Dimension Pro Brickmould Slider (WIN-N-145, Single Slider, Vinyl): U-Factor 0.25-0.32, SHGC 0.15-0.47, 236 options across 4."
---

Window · Vinyl Frame NFRC WIN · Product Line WIN-N-145

# Windsor Windows and Doors — Next Dimension Pro Brickmould Slider · Single Slider

EPA ENERGY STAR Version 7.0 certifies 236 variants inside Windsor Windows and Doors Next Dimension Pro Brickmould Slider, combining Vinyl frame construction with U-Factors spanning 0.25 to 0.32 and SHGC 0.15 to 0.47. Qualifying for Northern, North-Central, South-Central, Southern, this Single Slider family places #1,174 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.25

- **SHGC Range** : 0.15-0.47

- **Certified Options** : 236

- **Category Standing** : #1,174 of 1,352

## How does Windsor Windows and Doors Next Dimension Pro Brickmould Slider compare thermally against Window peers?

Windsor Windows and Doors Next Dimension Pro Brickmould Slider achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Windsor Windows and Doors Next Dimension Pro Brickmould Slider at rank #1,174 of 1,352 (tied with 81 others at 0.25, more insulating than 7.2% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.15-0.47 band.

Mapping NFRC SHGC values (0.15 to 0.47) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.25 floor sits above the 0.22 prescriptive Northern ceiling, 8 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.25 conducts 150.0 BTU/hr (+18.0 BTU/hr vs the 0.22 ceiling).

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 236 certified glazing combinations for Next Dimension Pro Brickmould Slider (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Equiv. Path | <= 0.22 | >= 0.17 | 8 packages (0 Most Eff.) |
| **North-Central** | Certified | <= 0.25 | <= 0.40 | 12 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 38 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 228 packages (0 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Magnolia Window and Door** — 400/4000 Single Hung](https://ela-ecolandscapingassn.org/windows/models/magnolia-window-and-door-400-4000-single-hung-413543/) | Vinyl | 0.25 | 0.16 | 228 |
| [**Custom Window Systems, Inc.** — PW-8150 Fixed](https://ela-ecolandscapingassn.org/windows/models/custom-window-systems-inc-pw-8150-fixed-413143/) | Vinyl | 0.25 | 0.14 | 212 |
| [**Sierra Pacific Windows** — Vinyl Builders Single Hung](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-builders-single-hung-414074/) | Vinyl | 0.25 | 0.12 | 268 |
| [**Westlake Royal Windows LLC** — 700 Horizontal Slider](https://ela-ecolandscapingassn.org/windows/models/westlake-royal-windows-llc-700-horizontal-slider-414466/) | Vinyl | 0.25 | 0.16 | 275 |
| [**Sierra Pacific Windows** — Vinyl Builders Single Slider](https://ela-ecolandscapingassn.org/windows/models/sierra-pacific-windows-vinyl-builders-single-slider-414076/) | Vinyl | 0.25 | 0.12 | 278 |

## What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [Pinnacle Clad Radius Direct Glaze](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/)

U-Factor 0.15–0.32 · 1,266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/)

Picture WindowMin U 0.16

### [Next Dimension Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-picture-414458/)

U-Factor 0.16–0.32 · 1,539 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-picture-414458/)

Picture WindowMin U 0.16

### [Next Dimension Radius](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-radius-414463/)

U-Factor 0.16–0.32 · 1,382 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-radius-414463/)

Picture WindowMin U 0.17

### [Next Dimension Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/)

U-Factor 0.17–0.32 · 1,610 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/)

Picture WindowMin U 0.17

### [Pinnacle Clad Direct Set 3.25" Frame](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/)

U-Factor 0.17–0.32 · 817 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/)

Picture WindowMin U 0.17

### [Pinnacle Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-414388/)

U-Factor 0.17–0.32 · 1,162 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-414388/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Next Dimension Pro Brickmould Slider appear below.

### How well does Next Dimension Pro Brickmould Slider by Windsor Windows and Doors insulate relative to Window benchmarks?

Across 236 tested NFRC glazing configurations, Windsor Windows and Doors Next Dimension Pro Brickmould Slider with Vinyl framing and Horizontal Slider (HSOX) style reaches a 0.25 minimum U-Factor and 0.15-0.47 SHGC band. It places #1,174 among 1,352 Window series—more insulating than 7.2%.

### Can homeowners install Next Dimension Pro Brickmould Slider in cold Northern ENERGY STAR counties?

While Windsor Windows and Doors Next Dimension Pro Brickmould Slider misses the <= 0.22 prescriptive mark (floor U 0.25), 8 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

### What conductive BTU/hr difference separates Next Dimension Pro Brickmould Slider from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.25 U-Factor yields 150.0 BTU/hr conductive transfer (+13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What homeowner profiles are a poor match for Windsor Windows and Doors Next Dimension Pro Brickmould Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Next Dimension Pro Brickmould Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

### Does Next Dimension Pro Brickmould Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 228 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Windsor Windows and Doors Next Dimension Pro Brickmould Slider, while total line SHGC reaches 0.47 in colder packages.

### What glazing share inside Next Dimension Pro Brickmould Slider qualifies as Most Efficient?

No. Zero of the 236 configurations in Windsor Windows and Doors Next Dimension Pro Brickmould Slider hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

### Do 2026 Next Dimension Pro Brickmould Slider installations qualify for IRS Section 25C tax credits?

Any Next Dimension Pro Brickmould Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### How can homeowners confirm delivered Windsor Windows and Doors Next Dimension Pro Brickmould Slider units match permits?

Verify NFRC ID WIN and series WIN-N-145 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Next Dimension Pro Brickmould Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)