---
title: "Windsor Windows and Doors Next Dimension Single Slider"
url: https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-single-slider-414456/
description: "Windsor Windows and Doors Next Dimension Single Slider (WIN-N-191, Single Slider, Vinyl): U-Factor 0.18-0.32, SHGC 0.12-0.49, 3241 options across 4 ENERGY."
---

Window · Vinyl Frame NFRC WIN · Product Line WIN-N-191 ENERGY STAR Most Efficient Eligible

# Windsor Windows and Doors — Next Dimension Single Slider · Single Slider

Windsor Windows and Doors Next Dimension Single Slider is a Single Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.18 across 3,241 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #477 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.49.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.18

- **SHGC Range** : 0.12-0.49

- **Certified Options** : 3,241

- **Category Standing** : #477 of 1,352

## How does Windsor Windows and Doors Next Dimension Single Slider compare thermally against Window peers?

Windsor Windows and Doors Next Dimension Single Slider achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Next Dimension Single Slider is 0.02 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.18-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 210 configurations meet ENERGY STAR Most Efficient criteria while 339 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-08-21 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 108.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 3,241 certified glazing combinations for Next Dimension Single Slider (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Most Efficient | <= 0.22 | >= 0.17 | 339 packages (60 Most Eff.) |
| **North-Central** | Most Efficient | <= 0.25 | <= 0.40 | 552 packages (112 Most Eff.) |
| **South-Central** | Most Efficient | <= 0.28 | <= 0.23 | 1,620 packages (64 Most Eff.) |
| **Southern** | Most Efficient | <= 0.32 | <= 0.23 | 2,911 packages (150 Most Eff.) |

## Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Amsco Windows** — VZ1 Hampton Casement](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-casement-412901/) | Vinyl | 0.18 | 0.09 | 3,164 |
| [**Amsco Windows** — VZ1 Hampton Awning](https://ela-ecolandscapingassn.org/windows/models/amsco-windows-vz1-hampton-awning-412902/) | Vinyl | 0.18 | 0.09 | 3,114 |
| [**Vinylmax LLC** — CA55/CA74 Casement](https://ela-ecolandscapingassn.org/windows/models/vinylmax-llc-ca55-ca74-casement-414257/) | Vinyl | 0.18 | 0.13 | 3,415 |
| [**MI Windows and Doors, LLC** — 1615 Polyvinyl Chloride (PVC) Sidelite](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-1615-polyvinyl-chloride-pvc-sidelite-413692/) | Vinyl | 0.18 | 0.06 | 3,045 |
| [**MI Windows and Doors, LLC** — 4300 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window](https://ela-ecolandscapingassn.org/windows/models/mi-windows-and-doors-llc-4300-polyvinyl-chloride-pvc-fixed-direct-se/) | Vinyl | 0.18 | 0.09 | 3,045 |

## What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [Pinnacle Clad Radius Direct Glaze](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/)

U-Factor 0.15–0.32 · 1,266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/)

Picture WindowMin U 0.16

### [Next Dimension Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-picture-414458/)

U-Factor 0.16–0.32 · 1,539 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-picture-414458/)

Picture WindowMin U 0.16

### [Next Dimension Radius](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-radius-414463/)

U-Factor 0.16–0.32 · 1,382 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-radius-414463/)

Picture WindowMin U 0.17

### [Next Dimension Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/)

U-Factor 0.17–0.32 · 1,610 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/)

Picture WindowMin U 0.17

### [Pinnacle Clad Direct Set 3.25" Frame](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/)

U-Factor 0.17–0.32 · 817 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/)

Picture WindowMin U 0.17

### [Pinnacle Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-414388/)

U-Factor 0.17–0.32 · 1,162 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-414388/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Next Dimension Single Slider appear below.

### Where does Windsor Windows and Doors Next Dimension Single Slider stand thermally among ENERGY STAR Window lines?

Across 3,241 tested NFRC glazing configurations, Windsor Windows and Doors Next Dimension Single Slider with Vinyl framing and Horizontal Slider (HSOX) style reaches a 0.18 minimum U-Factor and 0.12-0.49 SHGC band. It places #477 among 1,352 Window series—top 41.6%.

### Does Windsor Windows and Doors Next Dimension Single Slider qualify for the ENERGY STAR Northern Zone?

Windsor Windows and Doors Next Dimension Single Slider supplies 339 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

### What BTU/hr heat transfer results from Next Dimension Single Slider's 0.18 minimum U-Factor?

Using NFRC WIN U-Factor 0.18, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 108.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-24.0 BTU/hr margin).

### What are the practical limitations of specifying Next Dimension Single Slider?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Next Dimension Single Slider options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

### Is Next Dimension Single Slider suitable for sunbelt cooling-dominated homes?

Yes. 2,911 Southern-certified options inside Windsor Windows and Doors Next Dimension Single Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.

### Are all 3,241 Next Dimension Single Slider configurations ENERGY STAR Most Efficient?

Within Next Dimension Single Slider, 6.5% (210 of 3,241) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

### Can homeowners claim Form 5695 credits on Windsor Windows and Doors Next Dimension Single Slider in 2026?

Any Next Dimension Single Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

### Where are NFRC and IGCC identification marks located on Next Dimension Single Slider?

Match the NFRC thermal sticker for code WIN and line WIN-N-191 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Next Dimension Single Slider come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)
