description: "Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door (WIN-N-178, Swinging Entry Door (Single), Wood): U-Factor 0.27-0.28, SHGC."
---

Door · Wood Frame NFRC WIN · Product Line WIN-N-178

# Windsor Windows and Doors — Pinnacle Clad Narrow Stile Outswing Patio Door · Swinging Entry Door (Single)

With a minimum U-Factor of 0.27—+0.06 compared against the 0.21 Door median—Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door spans 35 tested options across South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code WIN, the Wood assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.13 and 0.18.

[Verify Label in v7 Zone Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom R310 Egress](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/)

- **Min U-Factor** : 0.27

- **SHGC Range** : 0.13-0.18

- **Certified Options** : 35

- **Category Standing** : #249 of 268

## How does Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door compare thermally against Door peers?

Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door achieves a 0.27 thermal floor across Door lines, placing #249 of 268 against the 0.21 category median.

### Cohort Minimum U-Factor Distribution

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

### Thermal Standing & NFRC Anatomy

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Door assemblies nationwide (median U 0.21), Pinnacle Clad Narrow Stile Outswing Patio Door is 0.06 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.27-0.28.

Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.13 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.27 U-Factor yields 162.0 BTU/hr transfer (+30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-17 certification.

## Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 35 certified glazing combinations for Pinnacle Clad Narrow Stile Outswing Patio Door (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| **Northern** | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| **North-Central** | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| **South-Central** | Certified | <= 0.28 | <= 0.23 | 35 packages (0 Most Eff.) |
| **Southern** | Certified | <= 0.32 | <= 0.23 | 35 packages (0 Most Eff.) |

## Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.27 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| [**Andersen Corporation** — 200 Series Hinged Patio Door - Inswing; Low-Threshold Sill](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-200-series-hinged-patio-door-inswing-low-thresh/) | Wood | 0.27 | 0.12 | 23 |
| [**Weather Shield Mfg., Inc.** — 8510/8610 Swing Door](https://ela-ecolandscapingassn.org/windows/models/weather-shield-mfg-inc-8510-8610-swing-door-414364/) | Wood | 0.27 | 0.11 | 63 |
| [**Andersen Corporation** — Residential Wood Entry Door - Outswing](https://ela-ecolandscapingassn.org/windows/models/andersen-corporation-residential-wood-entry-door-outswing-413020/) | Wood | 0.27 | 0.09 | 808 |
| [**ESWindows LLC** — ES-LG525 Entrance Door](https://ela-ecolandscapingassn.org/windows/models/eswindows-llc-es-lg525-entrance-door-413217/) | Aluminum | 0.27 | 0.09 | 54 |
| [**Neuma Door** — Folding Door](https://ela-ecolandscapingassn.org/windows/models/nan-ya-plastics-corporation-neuma-door-folding-door-413822/) | Composite | 0.27 | 0.09 | 15 |

## What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

Picture WindowMin U 0.15

### [Pinnacle Clad Radius Direct Glaze](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/)

U-Factor 0.15–0.32 · 1,266 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-radius-direct-glaze-414389/)

Picture WindowMin U 0.16

### [Next Dimension Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-picture-414458/)

U-Factor 0.16–0.32 · 1,539 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-picture-414458/)

Picture WindowMin U 0.16

### [Next Dimension Radius](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-radius-414463/)

U-Factor 0.16–0.32 · 1,382 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-radius-414463/)

Picture WindowMin U 0.17

### [Next Dimension Casement Picture](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/)

U-Factor 0.17–0.32 · 1,610 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-next-dimension-casement-picture-414454/)

Picture WindowMin U 0.17

### [Pinnacle Clad Direct Set 3.25" Frame](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/)

U-Factor 0.17–0.32 · 817 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-3-25-frame-414452/)

Picture WindowMin U 0.17

### [Pinnacle Clad Direct Set](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-414388/)

U-Factor 0.17–0.32 · 1,162 certified options.

[Inspect specs →](https://ela-ecolandscapingassn.org/windows/models/windsor-windows-and-doors-pinnacle-clad-direct-set-414388/)

## What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door appear below.

### How efficient is Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door compared with peer Door models?

Built with Wood framing in Entry Door Single-Lite (EDSL) style, Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door offers 35 Version 7.0 configurations from U 0.27 up to 0.28, posting +0.06 against the Door median of 0.21 with 0 Most Efficient picks.

### Does Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door qualify for the ENERGY STAR Northern Zone?

Northern Zone certification is absent for Pinnacle Clad Narrow Stile Outswing Patio Door (0 qualifying options, min U 0.27). Install this Entry Door Single-Lite (EDSL) product only within South-Central, Southern regions where lower SHGC caps apply.

### What conductive BTU/hr difference separates Pinnacle Clad Narrow Stile Outswing Patio Door from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.27 U-Factor yields 162.0 BTU/hr conductive transfer (+22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

### What are the practical limitations of specifying Pinnacle Clad Narrow Stile Outswing Patio Door?

Skip Pinnacle Clad Narrow Stile Outswing Patio Door if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Clad Narrow Stile Outswing Patio Door options exceeding U 0.22.

### What Southern ENERGY STAR v7.0 options exist in Pinnacle Clad Narrow Stile Outswing Patio Door?

Across South-Central, Southern, 35 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door, while total line SHGC reaches 0.18 in colder packages.

### What glazing share inside Pinnacle Clad Narrow Stile Outswing Patio Door qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 35 Pinnacle Clad Narrow Stile Outswing Patio Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

### What 2026 federal tax credit and Lead RRP rules apply to Pinnacle Clad Narrow Stile Outswing Patio Door?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Pinnacle Clad Narrow Stile Outswing Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

### How can homeowners confirm delivered Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door units match permits?

Verify NFRC ID WIN and series WIN-N-178 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

## Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Pinnacle Clad Narrow Stile Outswing Patio Door come directly from EPA ENERGY STAR ProductFinder records.

1.  [ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder](https://www.energystar.gov/productfinder/product/certified-windows/results) — **U.S. EPA ENERGY STAR**, Version 7.0 Live Catalog (checked 2026-11-23)
2.  [ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0](https://www.energystar.gov/sites/default/files/asset/document/ES_Residential_WDS_V7_Final%20Specification%202022.pdf) — **U.S. EPA ENERGY STAR**, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
3.  [Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage)](https://nfrc.org/windows-doors-skylights/faq/) — **National Fenestration Rating Council (NFRC)**, 2026 (checked 2026-11-23)
4.  [Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025)](https://www.irs.gov/credits-deductions/energy-efficient-home-improvement-credit) — **Internal Revenue Service (IRS)**, 2025/2026 Statutory Update (checked 2026-11-23)

[Verify Your Home Zone in Glass Etch & v7 Checker](https://ela-ecolandscapingassn.org/tools/window-glass-etch-decoder/) [Check Bedroom Egress for Replacement Windows](https://ela-ecolandscapingassn.org/tools/window-egress-scope-selector/) [Browse All ENERGY STAR Certified Lines](https://ela-ecolandscapingassn.org/windows/)

### Helpful Homeowner Guides

Compare typical installed prices, check local energy rules, and verify contractor licenses using public state records (2026-11-25).

- [Window Cost Guide](https://ela-ecolandscapingassn.org/windows/replacement-cost-and-financing/)
- [Siding & Door Costs](https://ela-ecolandscapingassn.org/siding/replacement-cost-2000-sq-ft/)
- [Find Licensed Contractors](https://ela-ecolandscapingassn.org/contractors/)
- [Climate Zone & City Lookup](https://ela-ecolandscapingassn.org/cities/)
- [Official Government Sources](https://ela-ecolandscapingassn.org/sources/)