Attic & Wall Insulation R-Values, FTC Rule & Product Matrix
Residential attic insulation targets range from R-30 in IECC Zone 1 up to R-60 across Zones 4 through 8 under EPA ENERGY STAR Seal and Insulate guidance across 36 certified product lines. Federal FTC 16 CFR Part 460 mandates standardized ASTM C177 and C518 testing alongside signed contractor receipts disclosing area, thickness, and installed R-value.
- Cold Climate Attic Target
- R-60
- FTC Test Methods
- ASTM C177 / C518
- Installer Receipt Law
- 16 CFR 460.17
- Certified EPA Lines
- 36 lines
Diagram: Attic Baffle Ventilation & IRC R702.7 Wall Vapor Control — what tolerances apply?
Cross-section framing diagram illustrates how continuous soffit air baffles and attic floor depth achieve Zone 1-8 targets without blocking eave ventilation.
Continuous exterior foam sheathing raises cavity sheathing temperature while soffit baffles keep attic insulation from blocking eave airflow.
Residential Insulation Material Matrix (R-Range & Vapor Class) — how do entries compare?
Compare blown cellulose, fiberglass batt, mineral wool, and spray polyurethane foam across R-value density, IRC vapor retarder classes, and R-38 bag coverage.
| Blown-In Cellulose | R-3.2 to R-3.8/in | Vapor Permeable (Class III) | ~29 sq ft/bag |
| Loose-Fill Fiberglass | R-2.2 to R-2.7/in | Vapor Permeable (Class III) | ~40 sq ft/bag |
| Fiberglass Batt (Faced / Unfaced) | R-2.9 to R-3.8/in | Kraft Class II / Unfaced Class III | Board / Batt / Pro SPF |
| Mineral Wool (Rockwool) Batt | R-3.7 to R-4.2/in | Vapor Permeable (Class III) | Board / Batt / Pro SPF |
| Open-Cell Spray Polyurethane Foam | R-3.5 to R-3.8/in | Vapor Permeable (Class III) | Board / Batt / Pro SPF |
| Closed-Cell Spray Polyurethane Foam | R-6.0 to R-7.0/in | Class II at >=1.5-2 in | Board / Batt / Pro SPF |
| Expanded Polystyrene (EPS) Rigid Board | R-3.6 to R-4.4/in | Semi-Permeable (Class II/III) | Board / Batt / Pro SPF |
| Extruded Polystyrene (XPS) Rigid Board | R-4.7 to R-5.0/in | Semi-Impermeable (~1.0 perm/in) | Board / Batt / Pro SPF |
| Polyisocyanurate (Polyiso) Foil-Faced | R-5.7 to R-6.5/in | Class I (Foil Facer) | Board / Batt / Pro SPF |
What insulation & air sealing guides and linked pages are available?
Representative EPA ENERGY STAR Seal and Insulate partner product lines from public dataset kphf-22jd appear below alongside quick material summaries.
ThermalStar®
Partner: Atlas Roofing Corporation · Type: Expanded Polystyrene Foam (EPS)
ENERTITE® G, and ENERTITE® X Open-cell Spray Polyurethane Foam Insulations
Partner: BASF Corporation · Type: Polyisocyanurate Foam (Polyiso)
SPRAYTITE® (COMFORT, COMFORT XL, LWP-L, SP, 158, 178 and 81206) and WALLTITE® US
Partner: BASF Corporation · Type: Polyisocyanurate Foam (Polyiso)
WALLTITE® (LWP, MAX, PLUS AND XL) Spray-Applied Insulations
Partner: BASF Corporation · Type: Polyisocyanurate Foam (Polyiso)
UltraTouch™ Denim Insulation
Partner: Bonded Logic, Inc. · Type: Cotton
Sustainable and InsulPure Building Insulation
Partner: CertainTeed Corporation · Type: Fiberglass
Accufoam CC-HFO
Partner: Creative Polymer Solutions, LLC · Type: Polyisocyanurate Foam (Polyiso)
Accufoam AF1
Partner: Creative Polymer Solutions, LLC · Type: Polyisocyanurate Foam (Polyiso)
Froth-Pak™ Polyurethane Foam Insulation
Partner: DuPont de Nemours, Inc. · Type: Polyisocyanurate Foam (Polyiso)
Styrofoam™ Brand Scoreboard, Square Edge, Tongue & Groove, High Load 40, High Load 60, and Residential Sheathing
Partner: DuPont de Nemours, Inc. · Type: Extruded Polystyrene Foam (XPS)
Dr. Energy, FRM, SANCTUARY and SANCTUARY DEFENSE
Partner: Greenfiber · Type: Cellulose
Heatlok® HFO High Lift
Partner: Huntsman Building Solutions · Type: Polyisocyanurate Foam (Polyiso)
What key threshold answers apply here?
Direct answers below clarify Zone 1-8 R-value tiers, FTC 16 CFR 460.17 installer receipt requirements, and EPA pre-1990 vermiculite asbestos bans.
How much attic R-value do cold Zones 4-8 need vs. warm Zones 1-3?
ENERGY STAR Seal and Insulate specifies R-60 attic insulation across Zones 4-8 (R-49 when roof clearance is tight), R-49 in Zones 2-3 (R-38 minimum at tight eaves), and R-30 in Zone 1.
What must appear on an FTC-compliant contractor insulation receipt?
Under FTC 16 CFR 460.17, installers must give customers a dated, signed contract or receipt showing coverage area, installed thickness, and achieved R-value backed by ASTM C177 or C518 testing.
Is pre-1990 grey pebble-like vermiculite attic insulation safe to vacuum?
No. EPA advises treating all pre-1990 vermiculite as asbestos-contaminated: do not handle, store items on top of, open walls near, or DIY-vacuum suspected vermiculite.
What buyer and compliance questions arise in this section?
Frequently asked buyer questions cover settled bag scaling, FTC R-per-inch prohibitions, wall vapor barriers, and IRC R316.4 foam fire barriers.
What attic R-value targets apply across IECC Zones 1 through 8?
Under ENERGY STAR Seal and Insulate (2021 IECC Table R402.1.3), uninsulated attics target R-30 in Zone 1, R-49 in Zones 2-3, and R-60 across Zones 4-8 (stepping down one tier where roof slope limits height at eaves).
Why can sellers not advertise a flat R-value per inch under FTC 16 CFR 460.20?
FTC R-Value Rule 16 CFR 460.20 prohibits flat 'R-per-inch' claims unless standardized ASTM C177 or C518 testing proves thermal resistance per inch does not decline at greater installed thickness.
What must appear on an insulation contractor's receipt under 16 CFR 460.17?
Federal law mandates a dated, signed contract or receipt specifying total coverage area (sq ft), installed thickness (inches), material type, and achieved R-value before final payment.
When is pre-1990 attic vermiculite dangerous to disturb?
EPA directs homeowners to assume grey-brown pebble vermiculite contains asbestos. Do not store boxes on it, open adjacent walls, or use a household or shop vacuum—disturbing it sends airborne fibers through living spaces.
Who should NOT install interior Class I polyethylene vapor barriers in walls?
Homes in warm/humid IECC Zones 1-3 should not install impermeable Class I plastic vapor barriers on the interior drywall side, because summer cooling drives outdoor moisture inward and traps condensation inside stud cavities.
Does spray polyurethane foam (SPF) require a drywall thermal barrier?
Yes. IRC Section R316.4 requires foam plastic insulation to be separated from interior living spaces by an approved 15-minute thermal barrier (typically 1/2-inch gypsum board) or tested attic/crawlspace ignition barrier.
How does settled bag count depend on existing attic insulation depth?
Settled bag volume scales directly with attic square footage divided by each product's labeled R-38 coverage chart and the net R-value gap needed to hit Zone 1-8 ENERGY STAR targets (R-30 to R-60).
How do attic soffit baffles protect against moisture and ice dams?
Rigid plastic or foam rafter vents preserve a continuous air channel from perforated soffit intakes up into the attic cavity, preventing blown insulation from blocking eave ventilation or touching cold roof decking.
Which official federal and state sources back this page?
All insulation metrics resolve to EPA ENERGY STAR Seal & Insulate, Federal Trade Commission 16 CFR Part 460, EPA vermiculite advisories, and IRC citations.
- Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
- ENERGY STAR Certified Insulation Dataset (kphf-22jd) — U.S. EPA ENERGY STAR, 2025-05 (checked 2026-11-23)
- 16 CFR Part 460 — Labeling and Advertising of Home Insulation (R-Value Rule) — Federal Trade Commission (eCFR), eCFR Nov 18, 2026 (checked 2026-11-23)
- Protect Your Family from Asbestos-Contaminated Vermiculite Insulation — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)
- International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering) — International Code Council (ICC), 2021/2024 IRC (cite only) (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)