Skip to main content
Field Calculator Backed by ENERGY STAR Seal & Insulate R-value tiers, FTC 16 CFR Part 460, BLS May 2025 wages, and EPA asbestos guidance.

Attic & Wall Insulation R-Value, Bag Count & FTC Rule Calculator

Determine exact ENERGY STAR Seal and Insulate target attic R-values (R-30 through R-60) and continuous exterior wall sheathing guidance for your IECC climate zone, estimate settled blown-in bag counts from existing attic depth, inspect statewide May 2025 BLS insulation installer median wages (SOC 47-2131), and screen pre-1990 attics for hazardous vermiculite asbestos before opening cavities.

Residential attic cavity with deep blown-in insulation and soffit air baffles between timber trusses
Residential attic cavity with deep blown-in insulation and soffit air baffles between timber trusses
Zones 4-8 Attic Target
R-60
FTC Test Method
ASTM C177 / C518
FTC Receipt Law
16 CFR 460.17
US Insulator Median
$23.62/hr

How do you run the insulation specification check interactively?

Enter project dimensions and select a state below to compute instant targets in local browser JavaScript—zero server upload or account registration required.

IECC / ENERGY STAR Climate Zone
Target Material & Existing Ceiling Fill
ENERGY STAR Attic Target
R-60
--
Settled Bag / Depth Need--
Wall & Floor Recommendation--
State Installer Median Wage--
FTC Receipt Law16 CFR Part 460.17
FTC 16 CFR 460.17 compliance check ready.
IRC Section R316.4 SPF thermal barrier reminder.

Diagram: Attic Baffle Ventilation & IRC R702.7 Wall Vapor Control — what site dimensions matter?

Consult the engineering schematic below while measuring structural cavities, opening clearances, glass stamps, or eave runs in the field.

Attic R30-R60 Insulation Depth and Wall Vapor Retarder AssemblyCross-section showing attic soffit air baffle maintaining eave ventilation above R30 to R60 blown insulation, paired with IRC R702.7 exterior continuous foam sheathing and interior vapor retarder selection.Attic Eave Baffle & R-Value DepthR-30 (Z1) / R-49 (Z2-3) / R-60 (Z4-8)Soffit baffle keeps eave air clearFTC 16 CFR 460.17: Signed bag/R-value receiptIRC R702.7 Wall Vapor ControlExt. Foam (R5-R10 Zones 3-8)Warms wood sheathingInterior Drywall FinishZ1-3: Class III latex (no poly)Z4-8: Class II/III + foam ratioPre-1990 attic pebbles? Do NOT vacuum

Continuous exterior foam sheathing raises cavity sheathing temperature while soffit baffles keep attic insulation from blocking eave airflow.

ENERGY STAR Recommended Home Insulation R-Values (Based on 2021 IECC Table R402.1.3) — which thresholds apply?

Every threshold enforced by the interactive calculator matches the published statutory and consensus reference matrix tabulated below.

Climate Zone Uninsulated Attic Existing 3-4 in Attic Floor Target Wall Sheathing Retrofit
Zone 1 R30 R25 R13 Code cavity fill
Zone 2 R49 R38 R13 Code cavity fill
Zone 3 R49 R38 R19 R5 insulative wall sheathing
Zones 4A & 4B R60 R49 R19 R5 to R10 wall sheathing
Zones 4C, 5 & 6 R60 R49 R30 R10 wall sheathing
Zones 7 & 8 R60 R49 R38 R10 wall sheathing

How can contractors or guides embed this calculator widget?

Preview the standalone zero-clutter iframe widget or copy the embed snippet below to display this calculator with attribution on contractor or municipal pages.

Open Standalone Embed Preview
<iframe src="https://ela-ecolandscapingassn.org/embed/insulation-r-value/" title="Attic & Wall Insulation R-Value, Bag Count & FTC Rule Calculator" width="100%" height="560" loading="lazy" style="border:1px solid #E5E7EB;border-radius:12px;"></iframe>

What field checks and statutory limitations govern this tool?

Key edge cases, legal receipt mandates, safety warnings, and 2026 incentive rules governing this calculation appear below.

How does this calculator convert target R-value into settled blown cellulose bags?

It subtracts estimated existing R-value (existing depth in inches multiplied by material R-per-inch) from your ENERGY STAR climate-zone target, then scales (attic area / 29 sq ft per R-38 bag) by (added R / 38) rounded up to full bags.

Who should NOT blow new attic insulation directly over existing attic material?

Homes with active roof leaks, blocked soffit intake eaves, unshielded knob-and-tube wiring, non-IC recessed ceiling lights, or pre-1990 pebble vermiculite must resolve safety hazards before adding loose-fill insulation.

What does EPA require if pre-1990 grey vermiculite granules are spotted?

U.S. EPA advises homeowners to assume all pre-1990 grey-silver vermiculite contains asbestos: never disturb it, store boxes on top of it, open wall cavities near it, or vacuum it with household or shop vacuums.

Why do FTC 16 CFR 460 bag charts vary across manufacturers?

Settled thickness and minimum weight per square foot depend on specific fiber density tested under ASTM C177 or C518. Always inspect the exact bag coverage chart delivered to the job site rather than generic guesses.

What written details must appear on an insulation contractor's FTC receipt?

Under federal rule 16 CFR 460.17, installing contractors must provide a dated, signed contract or receipt naming installed insulation type, thickness in inches, square footage covered, and final achieved R-value.

When does continuous wall sheathing (R5 to R10) become recommended?

ENERGY STAR Seal and Insulate recommends R5 continuous insulative sheathing in Climate Zone 3 and R5 to R10 rigid exterior foam sheathing across Zones 4 through 8 during exterior siding replacement.

How accurate are the BLS May 2025 insulator hourly wages displayed here?

Displayed wages reflect official statewide May 2025 Bureau of Labor Statistics median pay for SOC 47-2131 (national median $23.62/hr), excluding contractor markup, equipment rentals, baffle prep, and material costs.

Are 2026 attic insulation projects still eligible for IRS Section 25C?

No. Federal Section 25C tax credits expired December 31, 2025; 2026 attic air sealing and insulation upgrades shift to state-administered DOE HOMES ($8,000 max) and HEEHR ($14,000 household cap) rebate allocations.

Which official federal and state sources back this page?

Formula parameters and trade labor benchmarks come directly from the federal agencies and model code references cataloged below.

  1. Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
  2. 16 CFR Part 460 — Labeling and Advertising of Home Insulation (R-Value Rule) — Federal Trade Commission (eCFR), eCFR Nov 18, 2026 (checked 2026-11-23)
  3. Protect Your Family from Asbestos-Contaminated Vermiculite Insulation — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)
  4. Occupational Employment and Wage Statistics (OEWS) — State and Metropolitan Area Wages (SOC 47-2031, 47-2121, 47-2131) — U.S. Bureau of Labor Statistics, May 2025 (checked 2026-11-23)
  5. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)
  6. Home Energy Rebates Program (HOMES & HEEHR/HEAR) — U.S. Department of Energy (SCEP), 2026 Program Guidance (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros