Matanuska-Susitna Borough, Alaska Climate Zone, Housing Age & Hazard Profile
USFS April 2026 wildfire analytics across Matanuska-Susitna Borough, Alaska classify 51,664 buildings in direct exposure (92.2% vs 62.0% statewide) and 3,672 in indirect smoke/ember buffers, alongside ENERGY STAR Northern envelope targets across 13 postal ZIP areas and 117,613 residents under Home rule. Nationally, the county ranks #2,501 of 3,143 by lowest risk and records 2 OpenFEMA declarations.
- ENERGY STAR v7 Zone
- Northern
- Window U / SHGC
- <= 0.22 (eqv 0.23-0.26 w/ higher SHGC) | >= 0.17 (eqv >= 0.35 / >= 0.40)
- Attic Insulation Target
- R60 (R49 w/ existing)
- Pre-1980 Lead Risk
- 18.5%
What window, insulation, and wildfire benchmarks apply in Matanuska-Susitna Borough?
Matanuska-Susitna Borough enforces Northern EPA ENERGY STAR Version 7.0 window benchmarks (<= 0.22 (eqv 0.23-0.26 w/ higher SHGC) U-Factor, >= 0.17 (eqv >= 0.35 / >= 0.40) SHGC) alongside R60 (R49 w/ existing) attic and R10 insulative wall sheathing wall insulation goals.
National County Wildfire Safety Position
Wildfire Risk 79.6 pct (#2,501 of 3,143) positioned along the peer percentile scale.
| Building Parameter / Metric | Matanuska-Susitna Borough Requirement or Value | Comparison / Notes |
|---|---|---|
| ENERGY STAR v7.0 Window Zone | Northern | U-Factor <= 0.22 (eqv 0.23-0.26 w/ higher SHGC) · SHGC >= 0.17 (eqv >= 0.35 / >= 0.40) |
| Recommended Attic & Wall R-Value | Attic R60 (R49 w/ existing) · Wall R10 insulative wall sheathing | ENERGY STAR Seal & Insulate Tier |
| USFS Indexed Buildings & Share | 56,065 structures (13 ZIPs) | 18.25% of Alaska building inventory |
| Direct Wildfire Flame Exposure | 51,664 buildings (92.2%) | State average: 62.0% |
| Indirect Smoke / Ember Zone | 3,672 buildings (6.6%) | State average: 24.4% |
| Minimal Wildfire Exposure | 729 buildings (1.3%) | State average: 13.6% |
| OpenFEMA Declarations (2020–2026) | 2 events (+2.0 vs AK med) | Severe Storm: 1, Winter Storm: 1 |
| IECC & Building America Climate | Zone 7 (Very Cold) | Moisture regime: N/A |
| ACS 2023 Housing Age & Lead RRP Risk | 50,922 units (18.5% pre-1980) | 2.9% built pre-1960 · 13.3% age 65+ |
| ACS 2023 Primary Heating Fuel & Value | 70.6% gas / 7.7% electric | Median home value $319,200 |
| FEMA NRI Multi-Hazard & Sub-Grade | Relatively Moderate NRI (Wind 0.0, Hail 3.2) | EPA Radon Zone 2 · Water table 0.7 ft |
USFS spatial mapping places 55,336 structures in combined direct and indirect wildfire zones, leaving 729 minimal-risk structures (1.3% vs 13.6% Alaska average). Burn-probability standing ranks #2,382 of 3,143 U.S. counties (#1 = lowest burn prob.; 25.8 pts higher burn probability than the 50.0 pts median).
Historical OpenFEMA records between 2020 and 2026 show 2 OpenFEMA declarations touching Matanuska-Susitna Borough, exceeding Alaska's county median of no 2020-2026 declarations by 2 (Severe Storm: 1, Winter Storm: 1). Envelope upgrades balance Northern window efficiency against Class A fire shutters or fiber-cement cladding.
Census ACS 2023 records for Matanuska-Susitna Borough report a $319,200 median home value and 13.3% residents aged 65+. Because only 18.5% of 50,922 housing units in Matanuska-Susitna Borough were built before 1980, newer post-1980 framing dominates—shifting homeowner priorities from lead abatement toward air sealing, glass seal swaps, and continuous exterior foam.
FEMA NRI places Matanuska-Susitna Borough at a Relatively Moderate multi-hazard rating (wind 0.0, hail 3.2, riverine flood 0.0), paired with N/A moisture detailing. Sub-grade checks highlight EPA Radon Zone 2. USDA soil surveys show an average seasonal water table at 0.7 ft, making foundation downspout extensions (4–6 ft) and egress window-well drains essential.
What construction trade wage benchmarks apply near Matanuska-Susitna Borough?
Hourly labor figures for window, insulation, and framing crews in Matanuska-Susitna Borough come from May 2025 Bureau of Labor Statistics wage reports for Alaska.
Glazier Hourly Median (BLS May 2025)
$30.29/hr in Alaska (U.S. median $27.44/hr).
Insulation Installer Median (BLS May 2025)
$27.15/hr in Alaska (U.S. median $23.62/hr).
How do nearby counties compare on wildfire safety and ENERGY STAR zones?
Compare wildfire exposure percentages, pre-1980 housing shares, distance in miles, and ENERGY STAR zones across neighboring U.S. counties and sibling Alaska subdivisions.
| Nearby U.S. County | Distance | ENERGY STAR Zone | National Wildfire Rank | Risk vs. Matanuska-Susitna Borough |
|---|---|---|---|---|
| Anchorage Municipality, AK | 75.7 mi | Northern | #1,052 of 3,143 | -46.1 pts lower risk |
| Denali Borough, AK | 99.2 mi | Northern | #2,950 of 3,143 | +14.3 pts higher risk |
| Kenai Peninsula Borough, AK | 161.1 mi | Northern | #2,485 of 3,143 | -0.5 pts lower risk |
| Chugach Census Area, AK | 164.3 mi | Northern | #258 of 3,143 | -71.4 pts lower risk |
| Copper River Census Area, AK | 180.8 mi | Northern | #2,803 of 3,143 | +9.6 pts higher risk |
What code, wildfire, and Lead RRP questions affect Matanuska-Susitna Borough?
County-level compliance, pre-1980 ACS housing share, EPA radon zone, FEMA NRI wind hazard, and OpenFEMA storm history questions for Matanuska-Susitna Borough appear below.
What share of buildings in Matanuska-Susitna Borough, AK face direct or indirect wildfire risk?
Across 56,065 mapped structures in Matanuska-Susitna Borough, AK, direct fuel exposure reaches 92.2% (51,664 roofs) and indirect ember exposure covers 6.6% (3,672), while 1.3% sit in minimal exposure.
What is Matanuska-Susitna Borough's wildfire and burn-probability safety standing?
With lower wildfire risk than 20.4% national standing at #2,501 of 3,143 (tied with 2 others at 79.6 pts), Matanuska-Susitna Borough ranks #24 among 30 Alaska counties (#1 = lowest risk) and holds #2,382 of 3,143 (tied with 2 others at 75.8 pts) for burn probability.
How low must U-Factor and SHGC be for Matanuska-Susitna Borough windows?
Inspectors and buyers in Matanuska-Susitna Borough target Northern ratings (<= 0.22 (eqv 0.23-0.26 w/ higher SHGC) U-Factor; >= 0.17 (eqv >= 0.35 / >= 0.40) SHGC; <= 0.3 cfm/ft2 air leakage) under EPA ENERGY STAR Version 7.0.
How do you size attic cellulose bags for a 1,500 sq ft home in Matanuska-Susitna Borough?
Using R60 (R49 w/ existing) targets in Matanuska-Susitna Borough, contractors blow settled cellulose per ASTM C177/C518 coverage charts (roughly 29 sq ft per bag at R-38) while keeping soffit air vents unobstructed.
How does Matanuska-Susitna Borough's FEMA storm frequency compare to the AK county median?
FEMA records 2 storm or fire declarations in Matanuska-Susitna Borough since 2020 (Severe Storm: 1, Winter Storm: 1; +2.0 vs AK med). Pair continuous drainage barriers with corrosion-resistant fasteners.
Who should NOT install standard vinyl siding in Matanuska-Susitna Borough, AK?
Within Matanuska-Susitna Borough's 55,336 exposed structures (98.7%), avoid combustible cedar shakes and standard vinyl where local WUI rules apply; specify fiber cement, 1/8-in ember vent mesh, and gravel perimeter buffers.
What share of Matanuska-Susitna Borough, AK homes require Lead-Safe RRP window prep?
ACS 2023 shows 18.5% of 50,922 homes in Matanuska-Susitna Borough were built before 1980, elevating pre-1978 EPA Lead RRP checks alongside Alaska's $30.29/hr BLS glazier median (vs. $27.44/hr U.S.).
How do FEMA NRI hazard scores and soil drainage affect Matanuska-Susitna Borough envelopes?
Operating in IECC Zone 7 (EPA Radon Zone 2), paid exterior contractors disturbing painted surfaces in pre-1978 Matanuska-Susitna Borough homes must hold active federal U.S. EPA Lead-Safe RRP certification and provide the Renovate Right pamphlet.
Which official federal and state sources back this page?
Every building count, ACS 2023 housing metric, FEMA NRI wind score, EPA radon zone, and climate rule for Matanuska-Susitna Borough resolves directly to USFS, Census, FEMA, EPA, DOE, USDA, and BLS records.
- Wildfire Risk to Communities — State and County Building Exposure & Risk Ranks — USDA Forest Service, April 2026 Release (checked 2026-11-23)
- ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
- State-Level Residential Building Energy Codes & Energy Use Index — U.S. DOE Building Energy Codes Program (BECP), September 2026 (checked 2026-11-23)
- DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
- U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
- FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
- U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
- USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
- OpenFEMA Disaster Declarations Summaries v2 (2020-2026 Severe Storms, Hurricanes, Tornadoes & Fires) — Federal Emergency Management Agency (FEMA), v2 API (2020-2026) (checked 2026-11-23)
- Occupational Employment and Wage Statistics (OEWS) — State and Metropolitan Area Wages (SOC 47-2031, 47-2121, 47-2131) — U.S. Bureau of Labor Statistics, May 2025 (checked 2026-11-23)
- Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)