Skip to main content
Southern Zone · LA Southern ENERGY STAR Zone · IECC 2 · Wildfire Safety (#1 = lowest risk): #861 of 3,143 (tied with 2 others at 27.4 pts) · top 27.5%

St. Landry Parish, Louisiana Climate Zone, Housing Age & Hazard Profile

USFS April 2026 wildfire analytics across St. Landry Parish, Louisiana classify 34,172 buildings in direct exposure (58.5% vs 42.2% statewide) and 17,349 in indirect smoke/ember buffers, alongside ENERGY STAR Southern envelope targets across 15 postal ZIP areas and 80,869 residents under 2021 IECC with amendments. Nationally, the county ranks #861 of 3,143 by lowest risk and records 15 OpenFEMA declarations.

Size Attic Insulation
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
ENERGY STAR v7 Zone
Southern
Window U / SHGC
<= 0.32 | <= 0.23
Attic Insulation Target
R30 to R49
Pre-1980 Lead Risk
52.4%

What window, insulation, and wildfire benchmarks apply in St. Landry Parish?

St. Landry Parish enforces Southern EPA ENERGY STAR Version 7.0 window benchmarks (<= 0.32 U-Factor, <= 0.23 SHGC) alongside R30 to R49 attic and Zone 1-2 code baseline wall insulation goals.

National County Wildfire Safety Position

St. Landry Parish Wildfire Safety RankWildfire Risk 27.4 pct stands at rank #861 of 3,143, outperforming 72.6% of peers.Wildfire Risk 27.4 pctRank #861 of 3,143 (72.6% standing)Higher ExposureNational/Cohort Median (50th)Lowest Risk (#1)

Wildfire Risk 27.4 pct (#861 of 3,143) positioned along the peer percentile scale.

Building Parameter / Metric St. Landry Parish Requirement or Value Comparison / Notes
ENERGY STAR v7.0 Window Zone Southern U-Factor <= 0.32 · SHGC <= 0.23
Recommended Attic & Wall R-Value Attic R30 to R49 · Wall Zone 1-2 code baseline ENERGY STAR Seal & Insulate Tier
USFS Indexed Buildings & Share 58,453 structures (15 ZIPs) 2.35% of Louisiana building inventory
Direct Wildfire Flame Exposure 34,172 buildings (58.5%) State average: 42.2%
Indirect Smoke / Ember Zone 17,349 buildings (29.7%) State average: 26.3%
Minimal Wildfire Exposure 6,932 buildings (11.9%) State average: 31.5%
OpenFEMA Declarations (2020–2026) 15 events (equal to LA med) Hurricane: 10, Coastal Storm: 2, Severe Ice Storm: 2
IECC & Building America Climate Zone 2 (Hot-Humid) Moisture regime: A
ACS 2023 Housing Age & Lead RRP Risk 37,001 units (52.4% pre-1980) 15.0% built pre-1960 · 16.6% age 65+
ACS 2023 Primary Heating Fuel & Value 26.4% gas / 70.1% electric Median home value $142,900
FEMA NRI Multi-Hazard & Sub-Grade Relatively Moderate NRI (Wind 60.5, Hail 56.1) EPA Radon Zone 3 · Water table 1.4 ft

Evaluating ember and flame-front exposure separates St. Landry Parish into 58.5% direct interface, 29.7% indirect buffer, and 11.9% minimal exposure across 15 ZIP codes. State wildfire safety standing computes to #16 of 64 (tied with 1 other at 27.4 pts, lower wildfire risk than 73.4% of Louisiana counties, top 26.6%; #1 = lowest risk).

Historical OpenFEMA records between 2020 and 2026 show 15 OpenFEMA declarations touching St. Landry Parish, matching the Louisiana county median of 15.0 (Hurricane: 10, Coastal Storm: 2, Severe Ice Storm: 2). Envelope upgrades balance Southern window efficiency against Class A fire shutters or fiber-cement cladding.

Census ACS 2023 records for St. Landry Parish report a $142,900 median home value and 16.6% residents aged 65+. Roughly 52.4% of St. Landry Parish's 37,001 housing units predate 1980 (15.0% before 1960), meaning mid-century ranch and split-level envelopes frequently combine uninsulated wall cavities with Lead RRP paint checks.

FEMA NRI hurricane score reaches 92.2 and wind sits at 60.5, underscoring impact-rated glazing, ring-shank siding nails, and 6-in continuous gutters. Sub-grade checks highlight EPA Radon Zone 3. USDA soil surveys show an average seasonal water table at 1.4 ft, making foundation downspout extensions (4–6 ft) and egress window-well drains essential.

What construction trade wage benchmarks apply near St. Landry Parish?

Hourly labor figures for window, insulation, and framing crews in St. Landry Parish come from May 2025 Bureau of Labor Statistics wage reports for Louisiana.

Glazier Hourly Median (BLS May 2025)

$22.67/hr in Louisiana (U.S. median $27.44/hr).

Insulation Installer Median (BLS May 2025)

$22.76/hr in Louisiana (U.S. median $23.62/hr).

How do nearby counties compare on wildfire safety and ENERGY STAR zones?

Compare wildfire exposure percentages, pre-1980 housing shares, distance in miles, and ENERGY STAR zones across neighboring U.S. counties and sibling Louisiana subdivisions.

Nearby U.S. County Distance ENERGY STAR Zone National Wildfire Rank Risk vs. St. Landry Parish
Pointe Coupee Parish, LA 24.4 mi Southern #311 of 3,143 -17.5 pts lower risk
Evangeline Parish, LA 26.4 mi Southern #2,042 of 3,143 +37.6 pts higher risk
Lafayette Parish, LA 26.4 mi Southern #848 of 3,143 -0.4 pts lower risk
Acadia Parish, LA 32.2 mi Southern #993 of 3,143 +4.2 pts higher risk
Avoyelles Parish, LA 34.9 mi Southern #965 of 3,143 +3.3 pts higher risk

What code, wildfire, and Lead RRP questions affect St. Landry Parish?

County-level compliance, pre-1980 ACS housing share, EPA radon zone, FEMA NRI wind hazard, and OpenFEMA storm history questions for St. Landry Parish appear below.

What percentage of St. Landry Parish, LA roofs face flame-front or ember risk?

USDA Forest Service inventory maps 58,453 buildings in St. Landry Parish: 34,172 face direct exposure (58.5% vs. 42.2% in Louisiana), 17,349 face ember drift, and 6,932 remain minimal risk.

What is St. Landry Parish's wildfire and burn-probability safety standing?

Among 3,143 U.S. counties, St. Landry Parish places #861 of 3,143 (tied with 2 others at 27.4 pts) for lowest wildfire risk (top 27.5%) and #930 of 3,143 (tied with 2 others at 29.6 pts) for lowest burn probability, standing #16/64 inside Louisiana.

What thermal window ratings are required across St. Landry Parish, LA?

St. Landry Parish falls inside the Southern ENERGY STAR Version 7.0 boundary across 15 postal zones, enforcing U-Factor <= 0.32, SHGC <= 0.23, and <= 0.3 cfm/ft2 infiltration.

What attic R-value and bag-count formula apply to St. Landry Parish, LA homes?

ENERGY STAR Seal and Insulate specifies R30 to R49 for St. Landry Parish attics. Multiply square footage divided by 29 sq ft per R-38 bag by Target_R / 38, and obtain a signed FTC 16 CFR 460.17 receipt.

How does St. Landry Parish's FEMA storm frequency compare to the LA county median?

Federal OpenFEMA logs record 15 declarations touching St. Landry Parish between 2020 and 2026 (Hurricane: 10, Coastal Storm: 2, Severe Ice Storm: 2), standing equal to LA med. Heavy storm history favors 6-inch gutters and ASTM E2112 sill pans.

What exterior cladding choices hold up best against St. Landry Parish ember exposure?

Homeowners near St. Landry Parish's 34,172 direct-exposure buildings should skip standard vinyl and wood shingle siding in favor of non-combustible fiber cement installed with 6-in ground clearance and kickout flashing.

What BLS May 2025 hourly wage benchmarks apply to exterior crews in St. Landry Parish?

ACS 2023 shows 52.4% of 37,001 homes in St. Landry Parish were built before 1980, elevating pre-1978 EPA Lead RRP checks alongside Louisiana's $22.67/hr BLS glazier median (vs. $27.44/hr U.S.).

How do FEMA NRI hazard scores and soil drainage affect St. Landry Parish envelopes?

Operating in IECC Zone 2 (EPA Radon Zone 3), paid exterior contractors disturbing painted surfaces in pre-1978 St. Landry Parish homes must hold active federal U.S. EPA Lead-Safe RRP certification and provide the Renovate Right pamphlet.

Which official federal and state sources back this page?

Every building count, ACS 2023 housing metric, FEMA NRI wind score, EPA radon zone, and climate rule for St. Landry Parish resolves directly to USFS, Census, FEMA, EPA, DOE, USDA, and BLS records.

  1. Wildfire Risk to Communities — State and County Building Exposure & Risk Ranks — USDA Forest Service, April 2026 Release (checked 2026-11-23)
  2. ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
  3. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  4. Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
  5. State-Level Residential Building Energy Codes & Energy Use Index — U.S. DOE Building Energy Codes Program (BECP), September 2026 (checked 2026-11-23)
  6. DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
  7. U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
  8. FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
  9. U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
  10. USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
  11. OpenFEMA Disaster Declarations Summaries v2 (2020-2026 Severe Storms, Hurricanes, Tornadoes & Fires) — Federal Emergency Management Agency (FEMA), v2 API (2020-2026) (checked 2026-11-23)
  12. Occupational Employment and Wage Statistics (OEWS) — State and Metropolitan Area Wages (SOC 47-2031, 47-2121, 47-2131) — U.S. Bureau of Labor Statistics, May 2025 (checked 2026-11-23)
  13. U.S. Census Bureau 2024 Gazetteer & Vintage 2024 Population Estimates (States, Counties & Places) — U.S. Census Bureau, Vintage 2024 (checked 2026-11-23)
  14. Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros