Skip to main content
North-Central Zone · OH North-Central ENERGY STAR Zone · IECC 5 · Wildfire Safety (#1 = lowest risk): #987 of 3,143 (tied with 2 others at 31.4 pts) · top 31.5%

Vinton County, Ohio Climate Zone, Housing Age & Hazard Profile

USFS April 2026 wildfire analytics across Vinton County, Ohio classify 10,173 buildings in direct exposure (88.0% vs 37.3% statewide) and 1,387 in indirect smoke/ember buffers, alongside ENERGY STAR North-Central envelope targets across 6 postal ZIP areas and 12,545 residents under 2018 IECC with amendments. Nationally, the county ranks #987 of 3,143 by lowest risk and records no OpenFEMA disaster declarations.

Size Attic Insulation
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
ENERGY STAR v7 Zone
North-Central
Window U / SHGC
<= 0.25 | <= 0.40
Attic Insulation Target
R60 (R49 w/ existing)
Pre-1980 Lead Risk
47.6%

What window, insulation, and wildfire benchmarks apply in Vinton County?

Vinton County enforces North-Central EPA ENERGY STAR Version 7.0 window benchmarks (<= 0.25 U-Factor, <= 0.40 SHGC) alongside R60 (R49 w/ existing) attic and R5 to R10 insulative sheathing wall insulation goals.

National County Wildfire Safety Position

Vinton County Wildfire Safety RankWildfire Risk 31.4 pct stands at rank #987 of 3,143, outperforming 68.6% of peers.Wildfire Risk 31.4 pctRank #987 of 3,143 (68.6% standing)Higher ExposureNational/Cohort Median (50th)Lowest Risk (#1)

Wildfire Risk 31.4 pct (#987 of 3,143) positioned along the peer percentile scale.

Building Parameter / Metric Vinton County Requirement or Value Comparison / Notes
ENERGY STAR v7.0 Window Zone North-Central U-Factor <= 0.25 · SHGC <= 0.40
Recommended Attic & Wall R-Value Attic R60 (R49 w/ existing) · Wall R5 to R10 insulative sheathing ENERGY STAR Seal & Insulate Tier
USFS Indexed Buildings & Share 11,562 structures (6 ZIPs) 0.19% of Ohio building inventory
Direct Wildfire Flame Exposure 10,173 buildings (88.0%) State average: 37.3%
Indirect Smoke / Ember Zone 1,387 buildings (12.0%) State average: 10.7%
Minimal Wildfire Exposure 2 buildings (0.0%) State average: 52.0%
OpenFEMA Declarations (2020–2026) 0 events (equal to OH med) No declarations
IECC & Building America Climate Zone 5 (Cold) Moisture regime: A
ACS 2023 Housing Age & Lead RRP Risk 5,937 units (47.6% pre-1980) 26.6% built pre-1960 · 18.8% age 65+
ACS 2023 Primary Heating Fuel & Value 19.4% gas / 41.2% electric Median home value $131,700
FEMA NRI Multi-Hazard & Sub-Grade Very Low NRI (Wind 12.5, Hail 21.9) EPA Radon Zone 1 · Water table 2.2 ft

Disaggregating 11,562 local structures shows 10,173 directly abutting wildland fuels (88.0%) and 1,387 in indirect smoke/ember buffers (12.0%). Minimal-exposure share shifts -52.0 percentage points against OH baselines.

Emergency declaration records show no emergency declarations across 2020-2026 (No declarations), matching Ohio's county median of no 2020-2026 declarations. Exterior work enforces 2018 IECC with amendments U-Factors and attic R-values.

Delivered propane and heating oil serve 29.7% of Vinton County households (versus 19.4% utility gas and 41.2% electric), amplifying annual dollar payback from R-49/R-60 attic upgrades and low-U glazing. Roughly 47.6% of Vinton County's 5,937 housing units predate 1980 (26.6% before 1960), meaning mid-century ranch and split-level envelopes frequently combine uninsulated wall cavities with Lead RRP paint checks.

USDA soil surveys show an average seasonal water table at 2.2 ft, making foundation downspout extensions (4–6 ft) and egress window-well drains essential. Combined with EPA Radon Zone 1, basement egress retrofits should seal sill plates and install perimeter drainage before finishing sleeping rooms. FEMA NRI places Vinton County at a Very Low multi-hazard rating (wind 12.5, hail 21.9, riverine flood 0.0), paired with A moisture detailing.

What construction trade wage benchmarks apply near Vinton County?

Hourly labor figures for window, insulation, and framing crews in Vinton County come from May 2025 Bureau of Labor Statistics wage reports for Ohio.

Glazier Hourly Median (BLS May 2025)

$28.94/hr in Ohio (U.S. median $27.44/hr).

Insulation Installer Median (BLS May 2025)

$28.08/hr in Ohio (U.S. median $23.62/hr).

How do nearby counties compare on wildfire safety and ENERGY STAR zones?

Compare wildfire exposure percentages, pre-1980 housing shares, distance in miles, and ENERGY STAR zones across neighboring U.S. counties and sibling Ohio subdivisions.

Nearby U.S. County Distance ENERGY STAR Zone National Wildfire Rank Risk vs. Vinton County
Hocking County, OH 16.5 mi North-Central #870 of 3,143 -3.7 pts lower risk
Jackson County, OH 17.9 mi North-Central #1,122 of 3,143 +4.3 pts higher risk
Athens County, OH 24.2 mi North-Central #873 of 3,143 -3.6 pts lower risk
Meigs County, OH 27.0 mi North-Central #917 of 3,143 -2.2 pts lower risk
Ross County, OH 31.1 mi North-Central #732 of 3,143 -8.1 pts lower risk

What code, wildfire, and Lead RRP questions affect Vinton County?

County-level compliance, pre-1980 ACS housing share, EPA radon zone, FEMA NRI wind hazard, and OpenFEMA storm history questions for Vinton County appear below.

What percentage of Vinton County, OH roofs face flame-front or ember risk?

Evaluating Vinton County, Ohio shows 88.0% direct exposure and 12.0% indirect exposure across 11,562 total buildings, leaving 2 minimal-risk properties (0.0%).

How does Vinton County compare nationally and statewide for wildfire safety?

Statewide rankings put Vinton County at #82 of 88 Ohio subdivisions (#1 = lowest risk), while national wildfire rank sits at #987 of 3,143 (tied with 2 others at 31.4 pts) and burn probability stands at #1,027 of 3,143 (tied with 3 others at 32.7 pts).

What window air-leakage and U-Factor specs fit Vinton County?

Replacement windows across Vinton County, Ohio follow North-Central targets: <= 0.25 U-Factor, <= 0.40 SHGC, and air leakage capped at 0.3 cfm/ft2 alongside 2018 IECC with amendments.

How many blown cellulose insulation bags does a Vinton County attic upgrade require?

Size Vinton County attic jobs to R60 (R49 w/ existing) using our county estimator above (dividing attic area by 29 sq ft/bag scaled by Target_R / 38) and retain signed FTC 16 CFR 460.17 contractor receipts.

How does Vinton County's FEMA storm frequency compare to the OH county median?

OpenFEMA v2 records zero 2020-2026 envelope-relevant declarations in Vinton County, compared to the OH county median of 0.0. Standard IRC R703 flashing and 6-inch gutter spacing rules still govern local permits.

Who should NOT install standard vinyl siding in Vinton County, OH?

Within Vinton County's 11,560 exposed structures (100.0%), avoid combustible cedar shakes and standard vinyl where local WUI rules apply; specify fiber cement, 1/8-in ember vent mesh, and gravel perimeter buffers.

How much do pre-1980 homes in Vinton County trigger EPA Lead RRP paint rules?

With 47.6% pre-1980 housing across 5,937 units in Vinton County, contractors disturbing painted sashes must follow Lead RRP containment; BLS May 2025 statewide glazier pay averages $28.94/hr.

Does Vinton County require state-delegated or federal EPA Lead RRP verification?

Operating in IECC Zone 5 (EPA Radon Zone 1), paid exterior contractors disturbing painted surfaces in pre-1978 Vinton County homes must hold active federal U.S. EPA Lead-Safe RRP certification and provide the Renovate Right pamphlet.

Which official federal and state sources back this page?

Every building count, ACS 2023 housing metric, FEMA NRI wind score, EPA radon zone, and climate rule for Vinton County resolves directly to USFS, Census, FEMA, EPA, DOE, USDA, and BLS records.

  1. Wildfire Risk to Communities — State and County Building Exposure & Risk Ranks — USDA Forest Service, April 2026 Release (checked 2026-11-23)
  2. ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
  3. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  4. Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
  5. State-Level Residential Building Energy Codes & Energy Use Index — U.S. DOE Building Energy Codes Program (BECP), September 2026 (checked 2026-11-23)
  6. DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
  7. U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
  8. FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
  9. U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
  10. USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
  11. OpenFEMA Disaster Declarations Summaries v2 (2020-2026 Severe Storms, Hurricanes, Tornadoes & Fires) — Federal Emergency Management Agency (FEMA), v2 API (2020-2026) (checked 2026-11-23)
  12. Occupational Employment and Wage Statistics (OEWS) — State and Metropolitan Area Wages (SOC 47-2031, 47-2121, 47-2131) — U.S. Bureau of Labor Statistics, May 2025 (checked 2026-11-23)
  13. U.S. Census Bureau 2024 Gazetteer & Vintage 2024 Population Estimates (States, Counties & Places) — U.S. Census Bureau, Vintage 2024 (checked 2026-11-23)
  14. Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros