Skip to main content
North-Central Zone · VA North-Central ENERGY STAR Zone · IECC 4 · Wildfire Safety (#1 = lowest risk): #792 of 3,143 (tied with 2 others at 25.2 pts) · top 25.3%

Colonial Heights city, Virginia Climate Zone, Housing Age & Hazard Profile

Ranking #23 of 133 Virginia subdivisions by lowest wildfire risk—lower wildfire risk than 82.7% of Virginia counties, top 17.3%—and #792 of 3,143 U.S. counties nationally, Colonial Heights city holds 0.22% of statewide buildings, or 7,962 structures across 18,674 residents, inside EPA ENERGY STAR North-Central territory under 2021 IECC with amendments with 1 recent FEMA declaration since 2020.

Size Attic Insulation
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
ENERGY STAR v7 Zone
North-Central
Window U / SHGC
<= 0.25 | <= 0.40
Attic Insulation Target
R60 (R49 w/ existing)
Pre-1980 Lead Risk
74.4%

What window, insulation, and wildfire benchmarks apply in Colonial Heights city?

Colonial Heights city enforces North-Central EPA ENERGY STAR Version 7.0 window benchmarks (<= 0.25 U-Factor, <= 0.40 SHGC) alongside R60 (R49 w/ existing) attic and R5 to R10 insulative sheathing wall insulation goals.

National County Wildfire Safety Position

Colonial Heights city Wildfire Safety RankWildfire Risk 25.2 pct stands at rank #792 of 3,143, outperforming 74.8% of peers.Wildfire Risk 25.2 pctRank #792 of 3,143 (74.8% standing)Higher ExposureNational/Cohort Median (50th)Lowest Risk (#1)

Wildfire Risk 25.2 pct (#792 of 3,143) positioned along the peer percentile scale.

Building Parameter / Metric Colonial Heights city Requirement or Value Comparison / Notes
ENERGY STAR v7.0 Window Zone North-Central U-Factor <= 0.25 · SHGC <= 0.40
Recommended Attic & Wall R-Value Attic R60 (R49 w/ existing) · Wall R5 to R10 insulative sheathing ENERGY STAR Seal & Insulate Tier
USFS Indexed Buildings & Share 7,962 structures (1 ZIP) 0.22% of Virginia building inventory
Direct Wildfire Flame Exposure 1,185 buildings (14.9%) State average: 58.8%
Indirect Smoke / Ember Zone 3,152 buildings (39.6%) State average: 18.9%
Minimal Wildfire Exposure 3,625 buildings (45.5%) State average: 22.4%
OpenFEMA Declarations (2020–2026) 1 event (-1.0 vs VA med) Winter Storm: 1
IECC & Building America Climate Zone 4 (Mixed-Humid) Moisture regime: A
ACS 2023 Housing Age & Lead RRP Risk 8,126 units (74.4% pre-1980) 28.6% built pre-1960 · 18.3% age 65+
ACS 2023 Primary Heating Fuel & Value 35.5% gas / 56.8% electric Median home value $231,700
FEMA NRI Multi-Hazard & Sub-Grade Very Low NRI (Wind 9.6, Hail 5.2) EPA Radon Zone 1

USFS spatial mapping places 4,337 structures in combined direct and indirect wildfire zones, leaving 3,625 minimal-risk structures (45.5% vs 22.4% Virginia average). Burn-probability standing ranks #795 of 3,143 U.S. counties (#1 = lowest burn prob.; 24.7 pts lower burn probability than the 50.0 pts median).

Historical OpenFEMA records between 2020 and 2026 show 1 OpenFEMA declaration touching Colonial Heights city, shifting -1.0 relative to Virginia's 2 median county frequency (Winter Storm: 1). Envelope upgrades balance North-Central window efficiency against Class A fire shutters or fiber-cement cladding.

Census ACS 2023 records for Colonial Heights city report a $231,700 median home value and 18.3% residents aged 65+. With 74.4% of 8,126 homes built prior to 1980 (28.6% pre-1960), paid window or siding disturbance in Colonial Heights city triggers strict EPA Lead-Safe RRP containment rules across most neighborhoods.

FEMA NRI hurricane score reaches 59.0 and wind sits at 9.6, underscoring impact-rated glazing, ring-shank siding nails, and 6-in continuous gutters. Sub-grade checks highlight EPA Radon Zone 1. Maintain positive grade slope and 4–6 ft downspout discharge extensions around basement egress window wells.

What construction trade wage benchmarks apply near Colonial Heights city?

Hourly labor figures for window, insulation, and framing crews in Colonial Heights city come from May 2025 Bureau of Labor Statistics wage reports for Virginia.

Glazier Hourly Median (BLS May 2025)

$28.49/hr in Virginia (U.S. median $27.44/hr).

Insulation Installer Median (BLS May 2025)

$21.54/hr in Virginia (U.S. median $23.62/hr).

How do nearby counties compare on wildfire safety and ENERGY STAR zones?

Compare wildfire exposure percentages, pre-1980 housing shares, distance in miles, and ENERGY STAR zones across neighboring U.S. counties and sibling Virginia subdivisions.

Nearby U.S. County Distance ENERGY STAR Zone National Wildfire Rank Risk vs. Colonial Heights city
Petersburg city, VA 3.9 mi North-Central #848 of 3,143 +1.8 pts higher risk
Hopewell city, VA 5.7 mi North-Central #820 of 3,143 +0.9 pts higher risk
Prince George County, VA 11.0 mi North-Central #1,081 of 3,143 +9.2 pts higher risk
Chesterfield County, VA 13.2 mi North-Central #741 of 3,143 -1.6 pts lower risk
Henrico County, VA 13.3 mi North-Central #754 of 3,143 -1.2 pts lower risk

What code, wildfire, and Lead RRP questions affect Colonial Heights city?

County-level compliance, pre-1980 ACS housing share, EPA radon zone, FEMA NRI wind hazard, and OpenFEMA storm history questions for Colonial Heights city appear below.

How does Colonial Heights city split between direct, indirect, and minimal wildfire risk?

USFS April 2026 spatial data counts 7,962 structures in Colonial Heights city: 1,185 (14.9%) in direct flame-front exposure and 3,152 (39.6%) in indirect ember zones, leaving 3,625 (45.5%) at minimal risk.

How does Colonial Heights city compare nationally and statewide for wildfire safety?

National USFS comparisons place Colonial Heights city, VA at #792 of 3,143 (tied with 2 others at 25.2 pts) (#1 = lowest exposure; top 25.3%) and #23/133 within Virginia, alongside #795 of 3,143 (tied with 2 others at 25.3 pts) burn-probability standing.

What window air-leakage and U-Factor specs fit Colonial Heights city?

Inspectors and buyers in Colonial Heights city target North-Central ratings (<= 0.25 U-Factor; <= 0.40 SHGC; <= 0.3 cfm/ft2 air leakage) under EPA ENERGY STAR Version 7.0.

How many blown cellulose insulation bags does a Colonial Heights city attic upgrade require?

Using R60 (R49 w/ existing) targets in Colonial Heights city, contractors blow settled cellulose per ASTM C177/C518 coverage charts (roughly 29 sq ft per bag at R-38) while keeping soffit air vents unobstructed.

How does Colonial Heights city's FEMA storm frequency compare to the VA county median?

OpenFEMA v2 documents 1 severe weather or wildfire declaration in Colonial Heights city from 2020 to 2026 (-1.0 vs VA med; primary hazards: Winter Storm: 1). Prioritize kickout flashing and 3x4 downspouts.

What exterior cladding choices hold up best against Colonial Heights city ember exposure?

Properties inside the 54.5% combined direct and indirect wildfire exposure perimeter in Colonial Heights city should avoid standard vinyl siding, which melts under radiant ember heat. Non-combustible fiber cement (6-in grade gap) and metal soffit ember mesh improve resilience.

How much do pre-1980 homes in Colonial Heights city trigger EPA Lead RRP paint rules?

With 74.4% pre-1980 housing across 8,126 units in Colonial Heights city, contractors disturbing painted sashes must follow Lead RRP containment; BLS May 2025 statewide glazier pay averages $28.49/hr.

How do FEMA NRI hazard scores and soil drainage affect Colonial Heights city envelopes?

Operating in IECC Zone 4 (EPA Radon Zone 1), paid exterior contractors disturbing painted surfaces in pre-1978 Colonial Heights city homes must hold active federal U.S. EPA Lead-Safe RRP certification and provide the Renovate Right pamphlet.

Which official federal and state sources back this page?

Every building count, ACS 2023 housing metric, FEMA NRI wind score, EPA radon zone, and climate rule for Colonial Heights city resolves directly to USFS, Census, FEMA, EPA, DOE, USDA, and BLS records.

  1. Wildfire Risk to Communities — State and County Building Exposure & Risk Ranks — USDA Forest Service, April 2026 Release (checked 2026-11-23)
  2. ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
  3. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  4. Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
  5. State-Level Residential Building Energy Codes & Energy Use Index — U.S. DOE Building Energy Codes Program (BECP), September 2026 (checked 2026-11-23)
  6. DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
  7. U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
  8. FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
  9. U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
  10. USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
  11. OpenFEMA Disaster Declarations Summaries v2 (2020-2026 Severe Storms, Hurricanes, Tornadoes & Fires) — Federal Emergency Management Agency (FEMA), v2 API (2020-2026) (checked 2026-11-23)
  12. Occupational Employment and Wage Statistics (OEWS) — State and Metropolitan Area Wages (SOC 47-2031, 47-2121, 47-2131) — U.S. Bureau of Labor Statistics, May 2025 (checked 2026-11-23)
  13. U.S. Census Bureau 2024 Gazetteer & Vintage 2024 Population Estimates (States, Counties & Places) — U.S. Census Bureau, Vintage 2024 (checked 2026-11-23)
  14. Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros