Skip to main content
North-Central Zone · VA North-Central ENERGY STAR Zone · IECC 4 · Wildfire Safety (#1 = lowest risk): #1,489 of 3,143 (tied with 2 others at 47.4 pts) · top 47.4%

Salem city, Virginia Climate Zone, Housing Age & Hazard Profile

Ranking #89 of 133 Virginia subdivisions by lowest wildfire risk—lower wildfire risk than 33.1% of Virginia counties—and #1,489 of 3,143 U.S. counties nationally, Salem city holds 0.3% of statewide buildings, or 11,007 structures across 25,908 residents, inside EPA ENERGY STAR North-Central territory under 2021 IECC with amendments with 1 recent FEMA declaration since 2020.

Size Attic Insulation
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
ENERGY STAR v7 Zone
North-Central
Window U / SHGC
<= 0.25 | <= 0.40
Attic Insulation Target
R60 (R49 w/ existing)
Pre-1980 Lead Risk
69.8%

What window, insulation, and wildfire benchmarks apply in Salem city?

Salem city enforces North-Central EPA ENERGY STAR Version 7.0 window benchmarks (<= 0.25 U-Factor, <= 0.40 SHGC) alongside R60 (R49 w/ existing) attic and R5 to R10 insulative sheathing wall insulation goals.

National County Wildfire Safety Position

Salem city Wildfire Safety RankWildfire Risk 47.4 pct stands at rank #1,489 of 3,143, outperforming 52.7% of peers.Wildfire Risk 47.4 pctRank #1,489 of 3,143 (52.7% standing)Higher ExposureNational/Cohort Median (50th)Lowest Risk (#1)

Wildfire Risk 47.4 pct (#1,489 of 3,143) positioned along the peer percentile scale.

Building Parameter / Metric Salem city Requirement or Value Comparison / Notes
ENERGY STAR v7.0 Window Zone North-Central U-Factor <= 0.25 · SHGC <= 0.40
Recommended Attic & Wall R-Value Attic R60 (R49 w/ existing) · Wall R5 to R10 insulative sheathing ENERGY STAR Seal & Insulate Tier
USFS Indexed Buildings & Share 11,007 structures (1 ZIP) 0.3% of Virginia building inventory
Direct Wildfire Flame Exposure 1,018 buildings (9.2%) State average: 58.8%
Indirect Smoke / Ember Zone 6,215 buildings (56.5%) State average: 18.9%
Minimal Wildfire Exposure 3,774 buildings (34.3%) State average: 22.4%
OpenFEMA Declarations (2020–2026) 1 event (-1.0 vs VA med) Winter Storm: 1
IECC & Building America Climate Zone 4 (Mixed-Humid) Moisture regime: A
ACS 2023 Housing Age & Lead RRP Risk 11,096 units (69.8% pre-1980) 32.5% built pre-1960 · 19.5% age 65+
ACS 2023 Primary Heating Fuel & Value 54.3% gas / 39.9% electric Median home value $244,800
FEMA NRI Multi-Hazard & Sub-Grade Very Low NRI (Wind 36.5, Hail 12.7) EPA Radon Zone 1

Disaggregating 11,007 local structures shows 1,018 directly abutting wildland fuels (9.2%) and 6,215 in indirect smoke/ember buffers (56.5%). Minimal-exposure share shifts +11.9 percentage points against VA baselines.

Historical OpenFEMA records between 2020 and 2026 show 1 OpenFEMA declaration touching Salem city, shifting -1.0 relative to Virginia's 2 median county frequency (Winter Storm: 1). Envelope upgrades balance North-Central window efficiency against Class A fire shutters or fiber-cement cladding.

With 69.8% of 11,096 homes built prior to 1980 (32.5% pre-1960), paid window or siding disturbance in Salem city triggers strict EPA Lead-Safe RRP containment rules across most neighborhoods. Natural gas heats 54.3% of occupied Salem city homes compared with 39.9% electric heat, making winter conductive U-Factor control in IECC Zone 4 (Mixed-Humid) a primary heating-bill lever.

FEMA NRI hurricane score reaches 57.7 and wind sits at 36.5, underscoring impact-rated glazing, ring-shank siding nails, and 6-in continuous gutters. Sub-grade checks highlight EPA Radon Zone 1. Maintain positive grade slope and 4–6 ft downspout discharge extensions around basement egress window wells.

What construction trade wage benchmarks apply near Salem city?

Hourly labor figures for window, insulation, and framing crews in Salem city come from May 2025 Bureau of Labor Statistics wage reports for Virginia.

Glazier Hourly Median (BLS May 2025)

$28.49/hr in Virginia (U.S. median $27.44/hr).

Insulation Installer Median (BLS May 2025)

$21.54/hr in Virginia (U.S. median $23.62/hr).

How do nearby counties compare on wildfire safety and ENERGY STAR zones?

Compare wildfire exposure percentages, pre-1980 housing shares, distance in miles, and ENERGY STAR zones across neighboring U.S. counties and sibling Virginia subdivisions.

Nearby U.S. County Distance ENERGY STAR Zone National Wildfire Rank Risk vs. Salem city
Roanoke city, VA 5.4 mi North-Central #1,238 of 3,143 -8.0 pts lower risk
Roanoke County, VA 8.1 mi North-Central #1,983 of 3,143 +15.7 pts higher risk
Craig County, VA 16.2 mi North-Central #2,127 of 3,143 +20.3 pts higher risk
Montgomery County, VA 19.8 mi North-Central #1,901 of 3,143 +13.1 pts higher risk
Franklin County, VA 22.4 mi South-Central #1,307 of 3,143 -5.8 pts lower risk

What code, wildfire, and Lead RRP questions affect Salem city?

County-level compliance, pre-1980 ACS housing share, EPA radon zone, FEMA NRI wind hazard, and OpenFEMA storm history questions for Salem city appear below.

Where does wildfire exposure concentrate across Salem city's 11,007 buildings?

Across 11,007 mapped structures in Salem city, VA, direct fuel exposure reaches 9.2% (1,018 roofs) and indirect ember exposure covers 56.5% (6,215), while 34.3% sit in minimal exposure.

Where does Salem city rank out of 3,143 US counties for lowest wildfire risk?

With top 47.4% national standing at #1,489 of 3,143 (tied with 2 others at 47.4 pts), Salem city ranks #89 among 133 Virginia counties (#1 = lowest risk) and holds #1,452 of 3,143 (tied with 2 others at 46.2 pts) for burn probability.

What window air-leakage and U-Factor specs fit Salem city?

Inspectors and buyers in Salem city target North-Central ratings (<= 0.25 U-Factor; <= 0.40 SHGC; <= 0.3 cfm/ft2 air leakage) under EPA ENERGY STAR Version 7.0.

What R-value target and FTC receipt law govern Salem city attics?

ENERGY STAR Seal and Insulate specifies R60 (R49 w/ existing) for Salem city attics. Multiply square footage divided by 29 sq ft per R-38 bag by Target_R / 38, and obtain a signed FTC 16 CFR 460.17 receipt.

Does Salem city show above-average FEMA severe weather declarations?

FEMA records 1 storm or fire declaration in Salem city since 2020 (Winter Storm: 1; -1.0 vs VA med). Pair continuous drainage barriers with corrosion-resistant fasteners.

Does Salem city's 65.7% exposure share restrict siding materials?

Homeowners near Salem city's 1,018 direct-exposure buildings should skip standard vinyl and wood shingle siding in favor of non-combustible fiber cement installed with 6-in ground clearance and kickout flashing.

What BLS May 2025 hourly wage benchmarks apply to exterior crews in Salem city?

ACS 2023 shows 69.8% of 11,096 homes in Salem city were built before 1980, elevating pre-1978 EPA Lead RRP checks alongside Virginia's $28.49/hr BLS glazier median (vs. $27.44/hr U.S.).

Does Salem city require state-delegated or federal EPA Lead RRP verification?

Operating in IECC Zone 4 (EPA Radon Zone 1), paid exterior contractors disturbing painted surfaces in pre-1978 Salem city homes must hold active federal U.S. EPA Lead-Safe RRP certification and provide the Renovate Right pamphlet.

Which official federal and state sources back this page?

Every building count, ACS 2023 housing metric, FEMA NRI wind score, EPA radon zone, and climate rule for Salem city resolves directly to USFS, Census, FEMA, EPA, DOE, USDA, and BLS records.

  1. Wildfire Risk to Communities — State and County Building Exposure & Risk Ranks — USDA Forest Service, April 2026 Release (checked 2026-11-23)
  2. ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
  3. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  4. Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
  5. State-Level Residential Building Energy Codes & Energy Use Index — U.S. DOE Building Energy Codes Program (BECP), September 2026 (checked 2026-11-23)
  6. DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
  7. U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
  8. FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
  9. U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
  10. USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
  11. OpenFEMA Disaster Declarations Summaries v2 (2020-2026 Severe Storms, Hurricanes, Tornadoes & Fires) — Federal Emergency Management Agency (FEMA), v2 API (2020-2026) (checked 2026-11-23)
  12. Occupational Employment and Wage Statistics (OEWS) — State and Metropolitan Area Wages (SOC 47-2031, 47-2121, 47-2131) — U.S. Bureau of Labor Statistics, May 2025 (checked 2026-11-23)
  13. U.S. Census Bureau 2024 Gazetteer & Vintage 2024 Population Estimates (States, Counties & Places) — U.S. Census Bureau, Vintage 2024 (checked 2026-11-23)
  14. Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros