CrystaLite, Inc. — 5830 Venting Skylight · Skylight
EPA ENERGY STAR Version 7.0 certifies 146 variants inside CrystaLite, Inc. 5830 Venting Skylight, combining Vinyl frame construction with U-Factors spanning 0.28 to 0.43 and SHGC 0.14 to 0.56. Qualifying for Northern, North-Central, South-Central, Southern, this Skylight family places #2 of 16 among 16 Skylight families and posts 0.09 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.28
- SHGC Range
- 0.14-0.56
- Certified Options
- 146
- Category Standing
- #2 of 16
How does CrystaLite, Inc. 5830 Venting Skylight compare thermally against Skylight peers?
CrystaLite, Inc. 5830 Venting Skylight achieves a 0.28 thermal floor across Skylight lines, placing #2 of 16 against the 0.35 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), 5830 Venting Skylight reaches 0.28 on its lowest-conductivity package — #984 of 1,009 in Vinyl, tied with 20 others at 0.28, more insulating than 0.5% of Vinyl lines (+0.09 vs Vinyl peers). Pairing NFRC ID CRY across multi-pane fills shifts U-Factor from 0.43 down toward 0.28.
Mapping NFRC SHGC values (0.14 to 0.56) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.28 floor sits above the 0.22 prescriptive Northern ceiling, 146 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Lifecycle documentation anchors CRY to 2025-12-12 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 168.0 BTU/hr conductive loss (+27.3% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 146 certified glazing combinations for 5830 Venting Skylight (NFRC CRY) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 146 packages (47 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 90 packages (44 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 90 packages (44 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 90 packages (44 Most Eff.) |
Which competing Skylight series sit closest on U-Factor?
Inspect nearby Skylight competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Columbia Manufacturing Co., Ltd. — VSF Vinyl Self Flashing Skylight | Aluminum | 0.29 | 0.14 | 10 |
| CrystaLite, Inc. — 5842 Fixed Skylight | Aluminum | 0.29 | 0.16 | 130 |
| VELUX — TGF / TMF VELUX Sun Tunnel w/Flex Tube | Aluminum | 0.26 | 0.22 | 4 |
| VELUX — FCM Fixed Curb Mounted Skylight | Aluminum | 0.31 | 0.08 | 47 |
| Columbia Manufacturing Co., Ltd. — GL VCM-OF Skylight | Aluminum | 0.32 | 0.14 | 11 |
What other certified series does CrystaLite, Inc. produce?
Compare other active CrystaLite, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to CrystaLite, Inc. 5830 Venting Skylight appear below.
Where does CrystaLite, Inc. 5830 Venting Skylight stand thermally among ENERGY STAR Skylight lines?
CrystaLite, Inc. 5830 Venting Skylight spans 146 certified configurations with U-Factors between 0.28 and 0.43 and SHGC values from 0.14 to 0.56. Ranked #2 of 16 Skylight families, it carries 64 Most Efficient options.
Which glazing options in CrystaLite, Inc. 5830 Venting Skylight meet Northern climate limits?
With a 0.28 minimum U-Factor, CrystaLite, Inc. 5830 Venting Skylight cannot satisfy prescriptive <= 0.22 Northern targets, yet 146 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.
How much winter heat loss does 5830 Venting Skylight conduct across a 15 sq ft opening?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 168.0 BTU/hr on 5830 Venting Skylight's lowest-U package (0.28), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.43 transfer proportionally more energy.
Who should NOT choose CrystaLite, Inc. 5830 Venting Skylight for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 5830 Venting Skylight options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Can you install CrystaLite, Inc. 5830 Venting Skylight in Southern or South-Central zones?
Exactly 90 5830 Venting Skylight options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.56 glass.
How many CrystaLite, Inc. 5830 Venting Skylight variants earn ENERGY STAR Most Efficient?
No. Exactly 64 of 146 configurations (43.8%) earn ENERGY STAR Most Efficient status in 5830 Venting Skylight; the remaining standard v7.0 options pass base zone limits only.
Can homeowners claim Form 5695 credits on CrystaLite, Inc. 5830 Venting Skylight in 2026?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 CrystaLite, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How can homeowners confirm delivered CrystaLite, Inc. 5830 Venting Skylight units match permits?
Inspectors match the temporary NFRC sticker (U 0.28-0.43, SHGC 0.14-0.56) against permit drawings for line CRY-M-2. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for CrystaLite, Inc. 5830 Venting Skylight come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)