Harvey Industries, Inc. — Classic / Pro100 Double Hung · Double Hung
Positioning #477/1,352 in certified Window, Harvey Industries, Inc. Classic / Pro100 Double Hung pairs Vinyl frame construction with 1,965 glazing options rated between 0.17 and 0.48 SHGC across Northern, North-Central, South-Central, Southern. Across 16 certified Harvey Industries, Inc. product families, its thermal resistance spans 0.18 to 0.32 U-Factor and the line includes 389 ENERGY STAR Most Efficient packages (19.8% of line).
- Min U-Factor
- 0.18
- SHGC Range
- 0.17-0.48
- Certified Options
- 1,965
- Category Standing
- #477 of 1,352
How does Harvey Industries, Inc. Classic / Pro100 Double Hung compare thermally against Window peers?
Harvey Industries, Inc. Classic / Pro100 Double Hung achieves a 0.18 thermal floor across Window lines, placing #477 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Within the Vinyl cohort (0.19 median U-Factor), Classic / Pro100 Double Hung reaches 0.18 on its lowest-conductivity package — #354 of 1,009 in Vinyl, tied with 74 others at 0.18, more insulating than 57.6% of Vinyl lines, top 42.4% (-0.01 vs Vinyl peers). Pairing NFRC ID HII across multi-pane fills shifts U-Factor from 0.32 down toward 0.18.
Regional qualification covers Northern, North-Central, South-Central, Southern. 389 configurations meet ENERGY STAR Most Efficient criteria while 916 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors HII to 2025-01-13 certification (FENSTAR issued 2018-10-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 108.0 BTU/hr conductive loss (-18.2% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,965 certified glazing combinations for Classic / Pro100 Double Hung (NFRC HII) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 916 packages (139 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,265 packages (195 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 856 packages (100 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,096 packages (273 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.18 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Next Dimension Casement | Vinyl | 0.18 | 0.11 | 1,939 |
| JELD-WEN, inc. — Premium Vinyl (V-4500) Side Load Single Hung | Vinyl | 0.18 | 0.13 | 2,015 |
| Windsor Windows and Doors — Next Dimension Awning | Vinyl | 0.18 | 0.11 | 1,872 |
| MI Windows and Doors, LLC — 3500/3540/3500HP Polyvinyl Chloride (PVC) Fixed (Direct Set) Window | Vinyl | 0.18 | 0.14 | 2,284 |
| MI Windows and Doors, LLC — SR SH | DH PW Vinyl Picture Window | Vinyl | 0.18 | 0.09 | 1,587 |
What other certified series does Harvey Industries, Inc. produce?
Compare other active Harvey Industries, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Axio Tilt Turn Window
U-Factor 0.14–0.30 · 3,474 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Harvey Industries, Inc. Classic / Pro100 Double Hung appear below.
What U-Factor and SHGC range does Harvey Industries, Inc. Classic / Pro100 Double Hung achieve?
EPA ENERGY STAR v7.0 records 1,965 configurations for Harvey Industries, Inc. Classic / Pro100 Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.18 versus a 0.20 Window median. Only 389 options earn Most Efficient status.
Can homeowners install Classic / Pro100 Double Hung in cold Northern ENERGY STAR counties?
Yes, 916 packages satisfy Northern ENERGY STAR Version 7.0 rules in Classic / Pro100 Double Hung. Pairing multi-pane insulation down to 0.18 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How does a 3x5 ft Classic / Pro100 Double Hung window perform under a 40 deg F temperature drop?
At U 0.18, a standard 3x5 ft (15 sq ft) Classic / Pro100 Double Hung opening transfers 108.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -24.0 BTU/hr difference.
What are the practical limitations of specifying Classic / Pro100 Double Hung?
Cold-climate owners needing prescriptive U <= 0.22 should pass on Classic / Pro100 Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Harvey Industries, Inc. Classic / Pro100 Double Hung in Southern or South-Central zones?
Yes. 1,096 Southern-certified options inside Harvey Industries, Inc. Classic / Pro100 Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.48 SHGC on west-facing glass to avoid excess afternoon solar gain.
How many Harvey Industries, Inc. Classic / Pro100 Double Hung variants earn ENERGY STAR Most Efficient?
No. Exactly 389 of 1,965 configurations (19.8%) earn ENERGY STAR Most Efficient status in Classic / Pro100 Double Hung; the remaining standard v7.0 options pass base zone limits only.
What 2026 federal tax credit and Lead RRP rules apply to Classic / Pro100 Double Hung?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Classic / Pro100 Double Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How do building inspectors verify Classic / Pro100 Double Hung glass specs on job sites?
Match the NFRC thermal sticker for code HII and line HII-M-48 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Harvey Industries, Inc. Classic / Pro100 Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)