Skip to main content
Window · Wood Frame NFRC KKM · Product Line KKM-N-152 ENERGY STAR Most Efficient Eligible

Kolbe and Kolbe Millwork Co., Inc — Heritage Double Hung Studio · Picture Window

Positioning #19/1,352 in certified Window, Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio pairs Wood frame construction with 1,280 glazing options rated between 0.09 and 0.47 SHGC across Northern, North-Central, South-Central, Southern. Across 57 certified Kolbe and Kolbe Millwork Co., Inc product families, its thermal resistance spans 0.12 to 0.31 U-Factor and the line includes 762 ENERGY STAR Most Efficient packages (59.5% of line).

Min U-Factor
0.12
SHGC Range
0.09-0.47
Certified Options
1,280
Category Standing
#19 of 1,352

How does Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio compare thermally against Window peers?

Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio achieves a 0.12 thermal floor across Window lines, placing #19 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Heritage Double Hung StudioHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing Heritage Double Hung Studio (U 0.12).249<=0.15This model: U 0.123140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Heritage Double Hung Studio Cohort StandingMin U-Factor 0.12 stands at rank #19 of 1,352, outperforming 97.4% of peers.Min U-Factor 0.12Rank #19 of 1,352 (97.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), Heritage Double Hung Studio is 0.08 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Wood frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.12-0.31.

Mapping NFRC SHGC values (0.09 to 0.47) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 762 configurations meet ENERGY STAR Most Efficient criteria while 372 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-20 and v7.0 data certification on 2026-09-04. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.12 conducts 72.0 BTU/hr (-60.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,280 certified glazing combinations for Heritage Double Hung Studio (NFRC KKM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 372 packages (293 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 885 packages (731 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 922 packages (574 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,062 packages (586 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.12 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Kolbe and Kolbe Millwork Co., Inc produce?

Compare other active Kolbe and Kolbe Millwork Co., Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio appear below.

Where does Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 1,280 configurations for Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio covering Northern, North-Central, South-Central, Southern, dropping down to U 0.12 versus a 0.20 Window median. Only 762 options earn Most Efficient status.

Does Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio qualify for the ENERGY STAR Northern Zone?

Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio supplies 372 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.31, so inspect the NFRC order sheet before purchase.

How much winter heat loss does Heritage Double Hung Studio conduct across a 15 sq ft opening?

Using NFRC KKM U-Factor 0.12, a 15 sq ft Fixed Window (FIXD) assembly conducts 72.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-60.0 BTU/hr margin).

What homeowner profiles are a poor match for Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Heritage Double Hung Studio options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is Heritage Double Hung Studio suitable for sunbelt cooling-dominated homes?

Yes. 1,062 Southern-certified options inside Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.47 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 1,280 Heritage Double Hung Studio configurations ENERGY STAR Most Efficient?

Within Heritage Double Hung Studio, 59.5% (762 of 1,280) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What federal compliance checks govern 2026 Heritage Double Hung Studio window swaps?

Any Heritage Double Hung Studio purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Heritage Double Hung Studio?

Verify NFRC ID KKM and series KKM-N-152 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Kolbe and Kolbe Millwork Co., Inc Heritage Double Hung Studio come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros