Skip to main content
Door · Vinyl Frame NFRC QWP · Product Line QWP-M-141

Quaker Window Products — V300 Inswing Door · Swinging Entry Door (Single)

Positioning #29/268 in certified Door, Quaker Window Products V300 Inswing Door pairs Vinyl frame construction with 17,041 glazing options rated between 0.08 and 0.32 SHGC across Northern, North-Central, South-Central, Southern. Across 25 certified Quaker Window Products product families, its thermal resistance spans 0.16 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.16
SHGC Range
0.08-0.32
Certified Options
17,041
Category Standing
#29 of 268

How does Quaker Window Products V300 Inswing Door compare thermally against Door peers?

Quaker Window Products V300 Inswing Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. V300 Inswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing V300 Inswing Door (U 0.16).28<=0.15650.16-0.18This model: U 0.16510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

V300 Inswing Door Cohort StandingMin U-Factor 0.16 stands at rank #29 of 268, outperforming 79.9% of peers.Min U-Factor 0.16Rank #29 of 268 (79.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 25 certified Quaker Window Products series, this Swinging Entry Door, Single offers a 0.12 U-Factor adjustment span between 0.28 entry options and 0.16 top-performing glazing. Category standing is #29/268 (tied with 25 others at 0.16, more insulating than 79.9% of Door lines, top 20.1%).

Climate coverage for Quaker Window Products V300 Inswing Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 15,661 combinations qualify in the Northern Zone alongside 16,465 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Lifecycle documentation anchors QWP to 2026-09-08 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 96.0 BTU/hr conductive loss (-27.3% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 17,041 certified glazing combinations for V300 Inswing Door (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 15,661 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 15,661 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 16,465 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 16,465 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products V300 Inswing Door appear below.

What thermal performance numbers separate Quaker Window Products V300 Inswing Door from peers?

Testing puts Quaker Window Products V300 Inswing Door at rank #29 of 268 Door entries with U 0.16 to 0.28 across 17,041 configurations. Solar heat gain ranges between 0.08 and 0.32 across Northern, North-Central, South-Central, Southern.

Does Quaker Window Products V300 Inswing Door qualify for the ENERGY STAR Northern Zone?

Quaker Window Products V300 Inswing Door supplies 15,661 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

How does a 3x5 ft V300 Inswing Door window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), V300 Inswing Door at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying V300 Inswing Door?

Skip V300 Inswing Door if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on V300 Inswing Door options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in V300 Inswing Door?

Warm-climate homeowners have 16,465 Southern-approved options within V300 Inswing Door spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside V300 Inswing Door qualifies as Most Efficient?

V300 Inswing Door holds zero Most Efficient entries across its 17,041 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect V300 Inswing Door?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current V300 Inswing Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC QWP and product line QWP-M-141 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line QWP-M-141 and NFRC ID QWP before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products V300 Inswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros