Skip to main content
Window · Vinyl Frame NFRC RPI · Product Line RPI-M-4

Regency Plus, Inc. — 1522 Vinyl Awning · Awning (Projected)

Regency Plus, Inc. engineered the 1522 Vinyl Awning Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 43 glass-spacer combinations from 0.23 to 0.28 U-Factor and 0.16 to 0.39 SHGC. Relative to other Vinyl models tracked under NFRC RPI, its minimum U-Factor is 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.16-0.39
Certified Options
43
Category Standing
#936 of 1,352

How does Regency Plus, Inc. 1522 Vinyl Awning compare thermally against Window peers?

Regency Plus, Inc. 1522 Vinyl Awning achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1522 Vinyl AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 1522 Vinyl Awning (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1522 Vinyl Awning Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Regency Plus, Inc. 1522 Vinyl Awning at rank #936 of 1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.16-0.39 band.

Mapping NFRC SHGC values (0.16 to 0.39) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors RPI to 2025-05-16 certification (FENSTAR issued 2018-08-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 138.0 BTU/hr conductive loss (+4.5% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 43 certified glazing combinations for 1522 Vinyl Awning (NFRC RPI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 4 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 20 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 39 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 39 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Regency Plus, Inc. produce?

Compare other active Regency Plus, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Regency Plus, Inc. 1522 Vinyl Awning appear below.

What thermal performance numbers separate Regency Plus, Inc. 1522 Vinyl Awning from peers?

Testing puts Regency Plus, Inc. 1522 Vinyl Awning at rank #936 of 1,352 Window entries with U 0.23 to 0.28 across 43 configurations. Solar heat gain ranges between 0.16 and 0.39 across Northern, North-Central, South-Central, Southern.

Can homeowners install 1522 Vinyl Awning in cold Northern ENERGY STAR counties?

Northern qualification on 1522 Vinyl Awning relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 4 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

How do you calculate winter heat conduction for Regency Plus, Inc. 1522 Vinyl Awning?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1522 Vinyl Awning at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Regency Plus, Inc. 1522 Vinyl Awning for a residential project?

Skip 1522 Vinyl Awning if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1522 Vinyl Awning options exceeding U 0.22.

Can you install Regency Plus, Inc. 1522 Vinyl Awning in Southern or South-Central zones?

Yes, 1522 Vinyl Awning holds 39 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

How many Regency Plus, Inc. 1522 Vinyl Awning variants earn ENERGY STAR Most Efficient?

All 43 1522 Vinyl Awning listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect 1522 Vinyl Awning?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 1522 Vinyl Awning installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 1522 Vinyl Awning?

Inspectors match the temporary NFRC sticker (U 0.23-0.28, SHGC 0.16-0.39) against permit drawings for line RPI-M-4. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Regency Plus, Inc. 1522 Vinyl Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)