Skip to main content
Door · Vinyl Frame NFRC HGB · Product Line HGB-K-18

WeatherBarr Windows and Doors — Pinnacle Patio Door · Sliding Patio Door

EPA ENERGY STAR Version 7.0 certifies 126 variants inside WeatherBarr Windows and Doors Pinnacle Patio Door, combining Vinyl frame construction with U-Factors spanning 0.23 to 0.28 and SHGC 0.16 to 0.29. Qualifying for Northern, North-Central, South-Central, Southern, this Sliding Patio Door family places #162 of 268 among 268 Door families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.23
SHGC Range
0.16-0.29
Certified Options
126
Category Standing
#162 of 268

How does WeatherBarr Windows and Doors Pinnacle Patio Door compare thermally against Door peers?

WeatherBarr Windows and Doors Pinnacle Patio Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Pinnacle Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Pinnacle Patio Door (U 0.23).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.23430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Pinnacle Patio Door Cohort StandingMin U-Factor 0.23 stands at rank #162 of 268, outperforming 26.1% of peers.Min U-Factor 0.23Rank #162 of 268 (26.1% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows WeatherBarr Windows and Doors Pinnacle Patio Door standing at #162 of 268 certified Door product series, tied with 36 others at 0.23, more insulating than 26.1% of Door lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 100 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-08. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 126 certified glazing combinations for Pinnacle Patio Door (NFRC HGB) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 100 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 100 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 102 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 102 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does WeatherBarr Windows and Doors produce?

Compare other active WeatherBarr Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to WeatherBarr Windows and Doors Pinnacle Patio Door appear below.

What U-Factor and SHGC range does WeatherBarr Windows and Doors Pinnacle Patio Door achieve?

EPA ENERGY STAR v7.0 records 126 configurations for WeatherBarr Windows and Doors Pinnacle Patio Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Does WeatherBarr Windows and Doors Pinnacle Patio Door qualify for the ENERGY STAR Northern Zone?

While WeatherBarr Windows and Doors Pinnacle Patio Door misses the <= 0.22 prescriptive mark (floor U 0.23), 100 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How does a 3x5 ft Pinnacle Patio Door window perform under a 40 deg F temperature drop?

Using NFRC HGB U-Factor 0.23, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

What homeowner profiles are a poor match for WeatherBarr Windows and Doors Pinnacle Patio Door?

Do not specify Pinnacle Patio Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle Patio Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many Pinnacle Patio Door glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 102 Southern-approved options within Pinnacle Patio Door spanning SHGC down to 0.16. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does Pinnacle Patio Door carry EPA Most Efficient certification across its lineup?

Zero glazing builds inside Pinnacle Patio Door's 126 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 Pinnacle Patio Door window swaps?

Any Pinnacle Patio Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify Pinnacle Patio Door glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.23-0.28, SHGC 0.16-0.29) against permit drawings for line HGB-K-18. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for WeatherBarr Windows and Doors Pinnacle Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros