ZIP 32174 (Ormond Beach, FL) Window Specs, R-Value & Pre-1980 Lead Risk
Homeowners in ZIP 32174 (Ormond Beach, Florida) follow IECC Zone 2 and Southern ENERGY STAR criteria (<= 0.32 U-Factor, <= 0.23 SHGC; R30 to R49 attic / Zone 1-2 code baseline). Across 26,303 dwellings ($315,100 median value; +13.3% vs. Volusia County), 29.2% predate 1980 for U.S. EPA Federal RRP Program (EPA CDX) Lead RRP screening and 35.5% of 53,087 residents are aged 65+.
- ENERGY STAR v7 Zone
- Southern (<= 0.32)
- Attic R-Value Target
- R30 to R49
- Pre-1980 Lead Risk
- 29.2% (7,684 units)
- ACS Zip Population
- 53,087 (35.5% 65+)
What ENERGY STAR window limits, R-values, and Lead RRP risks govern ZIP 32174?
Verify exact ENERGY STAR v7.0 fenestration caps, IECC insulation depths, ACS 2023 housing age, and county hazard indicators for ZIP 32174 below.
| Building Envelope Parameter | ZIP 32174 (Ormond Beach) | Volusia County / Code Benchmark |
|---|---|---|
| ENERGY STAR v7.0 Window Zone | Southern (U <= 0.32) | SHGC <= 0.23 · Air leakage <= 0.3 cfm/ft2 |
| IECC Climate & Insulation Target | IECC Zone 2 · Attic R30 to R49 | Wall: Zone 1-2 code baseline · Moisture: A |
| Pre-1980 Housing (EPA Lead RRP) | 29.2% (7,684 of 26,303 units) | Volusia County avg: 35.4% · Pre-1960: 5.4% |
| Primary Home Heating Fuels | 1.7% gas / 96.0% electric | 0.5% propane · 0.3% oil |
| ACS Demographics & Home Value | Pop. 53,087 (35.5% age 65+) | Median value $315,100 · Income $67,817 |
| County Multi-Hazard & Radon | Relatively High NRI (Wind 87.8, Hail 39.2) | EPA Radon Zone 2 · Water table 0.8 ft |
Post-1980 Growth with Older Pockets: ZIP 32174 holds 29.2% pre-1980 homes (5.4% pre-1960) and 9.8% built since 2010—confirm property build year across Ormond Beach before budgeting RRP.
Solar & Conductive Control (Ormond Beach): With 96.0% electric heating vs. 1.7% piped gas, specifying Southern U <= 0.32 and SHGC <= 0.23 reduces peak HVAC compressor cycling.
Resale & Aging-in-Place Mix: Across 53,087 residents in Ormond Beach (35.5% age 65+, $315,100 median value), durable low-maintenance vinyl or composite trim boosts long-term value.
Humid/Hot Zone Durability: Enforcing Southern limits (U <= 0.32, SHGC <= 0.23) across ZIP 32174 cuts peak summer cooling load while protecting wall sheathing from wind-driven rain.
Tropical Storm Envelope Hardening: With FEMA hurricane (98.5) and wind (87.8) ratings in Volusia County, ZIP 32174 favors 6-inch continuous gutters and impact-tested sashes. USDA soils record a 0.8 ft average water table, making 4–6 ft downspout extensions critical.
Adjacent Tract Lead Exposure: Homeowners comparing 32174 (29.2% pre-1980) with New Smyrna Beach ZIP 32168 (-1.7 pts) and Port Orange ZIP 32127 (-9.5 pts) see how block age drives RRP prep costs.
Local Equity Benchmarks: Comparing Ormond Beach ZIP 32174 ($315,100; 53,087 pop) with ZIP 32168 ($310,200; 30,688 pop) and ZIP 32127 ($301,800) frames material upgrade budgets.
Permit & Bid Verification in Ormond Beach: Before signing a ZIP 32174 contract, confirm 2021 IECC with amendments permit pull responsibility, NFRC <= 0.32 stickers, and FTC 16 CFR 460.17 attic coverage receipts.
How do nearby Florida ZIP codes compare on pre-1980 housing and home value?
Compare ZIP 32174 (Ormond Beach) against four nearby Florida high-population ZIP codes on population, pre-1980 Lead RRP share, and median home value.
What should ZIP 32174 homeowners confirm before signing bids?
Verify whether Ormond Beach HOA standards or pre-1990 vermiculite safeguards constrain your planned ZIP 32174 window, siding, or attic upgrade below.
Municipal & HOA architectural limits in ZIP 32174
Neighborhood historic commissions or municipal amendments across Ormond Beach can restrict vinyl frames or require tempered impact glass beyond baseline Southern rules.
Pre-1990 attic vermiculite hazard check in ZIP 32174
Contractors inspecting pre-1990 attics across ZIP 32174 (29.2% pre-1980 stock) must leave suspected vermiculite untouched until EPA-accredited testing clears the space.
What window, insulation, and Lead RRP questions matter in ZIP 32174?
Direct answers for ZIP 32174 (Ormond Beach, FL) resolve ENERGY STAR window limits, Lead RRP triggers, attic R-values, and heating fuel impacts.
Which fenestration thermal limits govern ZIP 32174 (Ormond Beach, FL)?
Under ENERGY STAR Version 7.0, Ormond Beach ZIP 32174 enforces Southern thresholds of U-Factor <= 0.32, SHGC <= 0.23, and <= 0.3 cfm/ft2 air sealing under 2021 IECC with amendments.
How likely is pre-1978 lead paint in ZIP 32174 homes?
With 7,684 pre-1980 dwellings (29.2% share; 5.4% pre-1960) in ZIP 32174, disturbing painted pre-1978 trim in Ormond Beach triggers U.S. EPA Federal RRP Program (EPA CDX) HEPA containment rules.
What attic R-value does ENERGY STAR specify for ZIP 32174?
Homeowners upgrading ZIP 32174 attics in IECC Zone 2 target R30 to R49 settled depth plus Zone 1-2 code baseline under 2021 IECC with amendments and FTC 16 CFR 460.17.
How do ZIP 32174 heating fuels and radon affect upgrades?
In Ormond Beach ZIP 32174, 1.7% piped gas vs. 96.0% electric heating interacts with EPA Radon Zone 2 and Relatively High county storm scores (wind 87.8, hail 39.2).
Which official federal and state sources back this page?
Official Census, EPA, DOE, FEMA, and USDA primary datasets supporting every specification published for ZIP 32174 appear in full below.
- U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
- ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
- DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
- FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
- U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
- USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
- Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)