ZIP 28348 (Hope Mills, NC) Window Specs, R-Value & Pre-1980 Lead Risk
Envelope upgrades in ZIP 28348 (Hope Mills, NC) target R49 (R38 w/ existing) attic insulation and South-Central windows (U <= 0.28, <= 0.3 cfm/ft2 air leakage) under 2015 IECC with amendments. With 3,145 pre-1980 homes (21.8% share) and $203,700 median values (+10.9% vs. Cumberland County), North Carolina Health Hazards Control Unit (RRP Program) rules govern pre-1978 trim disturbance across Hope Mills.
- ENERGY STAR v7 Zone
- South-Central (<= 0.28)
- Attic R-Value Target
- R49 (R38 w/ existing)
- Pre-1980 Lead Risk
- 21.8% (3,145 units)
- ACS Zip Population
- 38,921 (11.1% 65+)
What ENERGY STAR window limits, R-values, and Lead RRP risks govern ZIP 28348?
Inspect ZIP 28348 (Hope Mills, NC) thermal requirements, pre-1980 Lead RRP counts, primary heating fuels, and multi-hazard metrics in the table below.
| Building Envelope Parameter | ZIP 28348 (Hope Mills) | Cumberland County / Code Benchmark |
|---|---|---|
| ENERGY STAR v7.0 Window Zone | South-Central (U <= 0.28) | SHGC <= 0.23 · Air leakage <= 0.3 cfm/ft2 |
| IECC Climate & Insulation Target | IECC Zone 3 · Attic R49 (R38 w/ existing) | Wall: R5 insulative wall sheathing · Moisture: A |
| Pre-1980 Housing (EPA Lead RRP) | 21.8% (3,145 of 14,413 units) | Cumberland County avg: 39.0% · Pre-1960: 4.1% |
| Primary Home Heating Fuels | 5.0% gas / 89.1% electric | 3.9% propane · 0.0% oil |
| ACS Demographics & Home Value | Pop. 38,921 (11.1% age 65+) | Median value $203,700 · Income $65,213 |
| County Multi-Hazard & Radon | Relatively Moderate NRI (Wind 75.9, Hail 79.4) | EPA Radon Zone 1 · Water table 1.8 ft |
Moderate Pre-1980 Minority (21.8%): Across 14,413 dwellings in ZIP 28348 (-17.2 pts vs. Cumberland County), 3,145 older residences require North Carolina Health Hazards Control Unit (RRP Program) checks while newer tracts focus on IGU glass.
Electric & Heat-Pump Majority (89.1%): Electric systems warm 89.1% of ZIP 28348 homes vs. 5.0% gas, placing dual emphasis on <= 0.23 solar rejection and R49 (R38 w/ existing) ceiling R-value.
Budget-Sensitive Retrofit Zone (28348): Keeping upgrades focused on R49 (R38 w/ existing) blown insulation and pocket vinyl inserts maximizes utility savings relative to $203,700 property values.
Warm-Transition Envelope (28348): Matching South-Central limits (U <= 0.28, SHGC <= 0.23) across Hope Mills prevents radiant heat gain while preserving winter comfort.
Tropical Storm Envelope Hardening: With FEMA hurricane (94.0) and wind (75.9) ratings in Cumberland County, ZIP 28348 favors 6-inch continuous gutters and impact-tested sashes. USDA soils record a 1.8 ft average water table, making 4–6 ft downspout extensions critical.
Neighboring ZIP Age Benchmark: While Hope Mills ZIP 28348 holds 21.8% pre-1980 dwellings, nearby ZIP 28314 (Fayetteville) registers 24.9% and ZIP 28311 (Fayetteville) posts 35.8%.
Nearby Home Value Delta: ZIP 28348 ($203,700) trades +18.4% vs. Fayetteville ZIP 28314 ($172,000) and +4.1% vs. Fayetteville ZIP 28311 ($195,700), alongside ZIP 28304 (Fayetteville: $154,300).
Permit & Bid Verification in Hope Mills: Before signing a ZIP 28348 contract, confirm 2015 IECC with amendments permit pull responsibility, NFRC <= 0.28 stickers, and FTC 16 CFR 460.17 attic coverage receipts.
How do nearby North Carolina ZIP codes compare on pre-1980 housing and home value?
Benchmark Hope Mills ZIP 28348 directly against four surrounding North Carolina ZCTAs (>= 25,000 residents) to track local Lead RRP and value shifts.
What should ZIP 28348 homeowners confirm before signing bids?
Confirm Cumberland County municipal permit riders, HOA covenants, and pre-1990 vermiculite asbestos precautions before starting exterior envelope work in ZIP 28348.
ZIP-to-county permit boundary check in Hope Mills
Municipal amendments inside Cumberland County or HOA architectural rules may enforce stricter impact glazing or cladding fire ratings than baseline South-Central standards.
Never disturb pebble vermiculite in older Hope Mills attics
Disturbing legacy pre-1990 vermiculite inside Hope Mills joist bays can release amphibole asbestos—order certified lab sampling before vacuuming or adding loose fill.
What window, insulation, and Lead RRP questions matter in ZIP 28348?
Review concise compliance answers for ZIP 28348 addressing South-Central glazing specs, pre-1980 Lead RRP density, FTC receipts, and local heating fuels.
What ENERGY STAR window U-Factor and SHGC apply in ZIP 28348?
Windows installed to South-Central criteria in ZIP 28348 (Cumberland County) must certify at U-Factor <= 0.28 and SHGC <= 0.23 on NFRC labels.
How likely is pre-1978 lead paint in ZIP 28348 homes?
Pre-1980 structures total 3,145 of 14,413 units in Hope Mills ZIP 28348 (21.8%). Paid window or siding retrofits on pre-1978 homes mandate active North Carolina Health Hazards Control Unit (RRP Program) certification.
What attic R-value does ENERGY STAR specify for ZIP 28348?
In Hope Mills ZIP 28348 (Mixed-Humid), EPA Seal and Insulate specifies R49 (R38 w/ existing) attic coverage and R5 insulative wall sheathing wall insulation alongside sealed ceiling air bypasses.
How do ZIP 28348 heating fuels and radon affect upgrades?
Electric & Heat-Pump Majority (89.1%): Electric systems warm 89.1% of ZIP 28348 homes vs. 5.0% gas, placing dual emphasis on <= 0.23 solar rejection and R49 (R38 w/ existing) ceiling R-value. Basement egress retrofits in Cumberland County also consider EPA Radon Zone 1 and Relatively Moderate multi-hazard exposure.
Which official federal and state sources back this page?
All housing, climate, multi-hazard, radon, and soil metrics for ZIP 28348 resolve directly to official U.S. federal datasets listed below.
- U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
- ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
- DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
- FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
- U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
- USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
- Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)